Glass — Hydrolytic resistance of glass grains at 98 degrees C — Method of test and classification

Verre — Résistance hydrolytique du verre en grains à 98 degrés C — Méthode d'essai et classification

General Information

Status
Withdrawn
Publication Date
30-Sep-1981
Withdrawal Date
30-Sep-1981
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Oct-1985
Ref Project

Relations

Buy Standard

Standard
ISO 719:1981 - Glass -- Hydrolytic resistance of glass grains at 98 degrees C -- Method of test and classification
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 719:1981 - Glass — Hydrolytic resistance of glass grains at 98 degrees C — Method of test and classification Released:10/1/1981
French language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

International Standard
@ 7'g
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION*MEXYHAPO~HAR OPTAHMJAUMR no CTAHnAPTM3AUMH.ORGANlS~TlON INTERNATIONALE DE NORMALISATION
Glass - Hydrolytic resistance of glass grains at 98 OC -
Method of test and classification
Verre - Résistance hydroiytique du verre en grains à 99 OC - Méthode d'essai et classification
First edition - 1981-10-15
UDC 666.1 : 620.193
Ref. No, ISO719-1981 (E)
Descriptors : glass, chemical resistance, hydrolytic resistance, tests, classifications.
8
c
s
Price based on 3 pages

---------------------- Page: 1 ----------------------
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards institutes (IS0 member bodies). The work of developing lnter-
national Standards is carried out through IS0 technical committees. Every member
body interested in a subject for which a technical committee has been set up has the
right to be represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council.
International Standard IS0 719 was developed by Technical Committee ISO/TC 48,
Laboratory glassware and related apparatus, and was circulated to the member bodies
in November 1979.
It has been approved by the member bodies of the following countries :
Poland
Australia Hungary
Canada India Romania
Egypt, Arab Rep. of Italy Spain
France Korea, Rep. of United Kingdom
Germany, F. R. Netherlands USSR
The member body of the following country expressed disapproval of the document on
technical grounds :
Czechoslovakia
This International Standard cancels and replaces IS0 Recommendation R 719-1968 of
which it constitutes a technical revision.
~r International Organization for Standardization, 1981 O
Printed in Switzerland

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD IS8 719-1981 (E)
Glass - Hydrolytic resistance of glass grains at 98 OC -
Method of test and classification
IS0 1042, Laboratory glassware - One-mark volumetric
1 Scope and field of application
flasks.
This International Standard specifies
IS0 1773, Laboratory glassware - Boiling flasks (narrow-
necked).
a) a method for determining the hydrolytic resistance of
glass grains at 98 OC. The resistance is measured and ex-
pressed by the volume of acid required for titration of the
3 Reagents
alkali extracted from unit mass of glass, and may also be ex-
pressed by the amount of sodium oxide equivalent to this
During the analysis, use only reagents of recognized analytical
volume of acid;
grade.
b) a classification of glass according to the hydrolytic
resistance determined by the method of this International
3.1 Distilled or deionized water, of high purity, complying
Standard.
with the following requirements when tested immediately
before use : it shall be free from dissolved gases and heavy
NOTES
metals, particularly copper, as shown by the dithizone test; it
shall have a specific conductivity not exceeding 1 x 10-4 S/m
1 The test method of this International Standard is recommended for
use on the less resistant types of glass. For the more resistant glasses, at 20 OC; and it shall be neutral to methyl red.
the method specified in IS0 720 is preferable.
2 It must be emphasised that there is no exact correlation between
3.2 Hydrochloric acid, standard volumetric solution
the classification of this international Standard and the classification of
[c(HCI) = 0,Ol mol/ll.
IS0 720, and it is therefore essential to identify which classification is
being used.
Buffer solution, pH = 5,2.
3.3
Add 92,8 mi of a citric acid solution [c(C6H8O7) =~moi/il to
107,2 ml of a disodium hydrogen phosphate solution
2 References
[c(Na2HP04) = 0,2 mol/ll, or alternatively, dissolve 1,02 g of
potassium hydrogen phthalate (C8HbK04) in 30 ml of sodium
IS0 565, Test sieves - Woven metal wire cloth and perforated
hydroxide solution [e (NaOH) = 0,l mol/ll and add carbonate-
plate - Nominal size of apertures.
free water to 100 ml.
IS0 648, Laboratory glassware - One-mark pipettes.
3.4 Methyl red, indicator solution.
IS0 720, Glass - Hydrolytic resistance of glass grains at Dissolve 25 mg of the sodium salt of methyl red
121 OC - Method of test and classification. (CI5Hl4N3Na02) in 100 ml of water (3.1).
1

---------------------- Page: 3 ----------------------
IS0 719-1981 (E)
4 Apparatus
NOTE - The use of sieve O is recommended to retain larger pieces of
glass and to avoid heavy wear of sieve A.
Ordinary laboratory apparatus, and
Thermometer, covering the range of 90 to 110 OC,
4.12
Balance, accurate to f 5 mg or better
4.1
capable of being read to an accuracy of f 0.2 OC.
4.2 Burettes, of suitable capacity, as follows :
4.13 Heating bath, gas or electrically heated, ther-
-
5 ml, graduated in 0,02 ml;
mostatically controlled, of capacity sufficient to contain 1 litre
of liquid for each flask used in the test and capable of carrying
-
2 ml or 1 ml, graduated in 0,Ol ml.
out the heating cycle specified in clause 6.
The capacity of the burettes shall be chosen according to the
expected consumption of hydrochloric acid (3.2).
Approximate dimensions
in millimetres
4.3 Pipette, 25 ml, complying with the requirements of
class A of IS0 648.
4.4 One-mark volumetric flasks, 50 ml, complying with
the requirements of class A of IS0 1042, made of chemically
resistant glass, and with glass stoppers. It is advisable to select
flasks with the graduation line in the lower half of the neck.
Before use, each new flask shall be pre-treated by filling to
above the graduation mark with water and treating three times
in accordance with the heating procedure specified in clause 6,
using a fresh quantity of water in the flask each time.
NOTE - Flasks made from vitreous silica may also be used, in which
case the pre-treatment is not required.
4.5 Conical flasks, 100 ml, complying with the require-
ments of IS0 1773. New flasks shall be pre-treat
...

@ 719
Norme internationale
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION~MEXYHAPO,ltiAi7 OPrAHHOAUHR ii0 CTAHAAPTH3AUMHWRGANlSATlON INTERNATIONALE DE NORMALISATION
Verre - Résistance hydrolytique du verre en grains à
98 OC - Méthode d'essai et classification
._
Glass - Hydrolytic resistance of glass grains at 93 OC - Method of test and classification
Première édition - 1981-10-15
CDU 666.1 : 620.193 Réf. no : ISO719-1981 (FI
Descripteurs : verre, résistance chimique, résistance hydrolytique, essais, classification.
Prix basé sur 3 pages

---------------------- Page: 1 ----------------------
Avant-propos
L'ISO (organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
des Normes internationales est confiée aux comités techniques de I'ISO. Chaque
comité membre intéressé par une étude a le droit de faire partie du comité technique
correspondant. Les organisations internationales, gouvernementales et non gouverne-
mentales, en liaison avec I'ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I'ISO.
La Norme internationale IS0 719 a été élaborée par le comité technique ISO/TC 48,
Verrerie de laboratoire et appareils connexes, et a été soumise aux comités membres
en novembre 1979.
Les comités membres des pays suivants l'ont approuvée
Allemagne, R. F. Espagne Pays- Bas
Australie France Pologne
Canada Hongrie Roumanie
Corée, Rép. de Inde Royaume- Uni
Égypte, Rép. arabe d' Italie URSS
Le comité membre du pays suivant l'a désapprouvée pour des raisons techniques :
Tchécoslovaquie
Cette Norme internationale annule et remplace la Recommandation ISO/R 719-1968,
dont elle constitue une révision technique.
0
Organisation internationale de normalisation, 1981
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE IS0 719-1981 (FI
Verre - Résistance hydrolytique du verre en grains à
98 OC - Méthode d‘essai et classification
IS0 1042, Verrerie de laboratoire - Fioles jaugées à un trait.
1 Objet et domaine d’application
IS0 1773, Verrerie de laboratoire - Fioles coniques et ballons
La présente Norme internationale spécifie
(à col étroit).
a) une méthode de détermination de la résistance hydro
lytique du verre en grains à 98 OC. La résistance est mesurée
et exprimée par le volume d’acide nécessaire au titrage de
l’alcali extrait par unité de masse du verre, et peut égale-
3 Réactifs
ment être exprimée par la quantité d‘oxyde desodium équi-
valent à ce volume d’acide;
Au cours de l’analyse, utiliser uniquement des réactifs de qua-
lité analytique reconnue.
une classification du verre selon la résistance hydrolyti-
b)
par la méthode de la présente Norme inter-
que déterminée
3.1 Eau distillée ou déionisée, d‘une grande pureté, satis-
nationale.
faisant aux conditions suivantes auand elle est vérifiée immé-
-
: elle doit être exempte de gaz dis-
diatement avant utilisation
NOTES
sous et de métaux lourds, en particulier de cuivre, ce qui peut
être déterminé par un essai à la dithizone; elle doit avoir une
1 L‘utilisation de la méthode décrite dans la présente Norme interna-
conductivité spécifique ne dépassant pas 1 x 10-4 S/m à
tionale est recommandée pour les types de verre peu résistants. Pour
les verres de plus grande résistance, la méthode spécifiée dans 20 Oc; elle doit être neutre au rouge de méthyle.
I’ISO 720 est préférable.
3.2 Acide chlorhydrique, solution titrée,
2 II y a lieu d‘attirer l’attention sur le fait qu’il n’y a pas de corrélation
‘‘(HCI) = Oro’
exacte entre la classification donnée par la présente Norme internatio-
nale et celle de I‘ISO 720, et il est en conséquence primordial d’indiquer
laquelle des classifications est utilisée.
Solution tampon, pH = 5,2.
3.3
Ajouter 92,8 ml d’une solution d’acide citrique MC6H 07) =
4 mol/ll à 107,2 ml d’une solution de monohy I- rog nophos-
04
2 Références
phate de sodium [c(Na2HP04) = 0,2 mol/ll OU, à défaut, dis-
soudre 1,02 g d’hydrogénophtalate de potassium dans 30 ml
IS0 565, Tamis de contrôle - Toilesmétalliques et tôlesperfo-
de solution dthydroxyde de sodium [c(NaOH) = mol/ll et
rées - Dimensions nominales des ouvertures.
compléter à 100 ml avec de l’eau exempte de carbonates.
IS0 648, Verrerie de laboratoire - Pipettes à un trait.
3.4
Rouge de méthyle, solution d‘indicateur.
IS0 720, Verre - Résistance hydrolytique du verre en grains à Dissoudre 25 mg de sel de sodium de rouge de méthyle
121 OC - Méthode d’essai et classification (CI5Hl4N3NaO2) dans 100 ml d’eau (3.1).
1

---------------------- Page: 3 ----------------------
IS0 719-1981 (FI
NOTE - L'utilisation du tamis O est recommandée, afin de retenir les
4 Appareillage
plus grosses particules de verre et d'éviter une usure trop importante
du tamis A.
Matériel courant de laboratoire, et
Balance, précise à & 5 mg ou moins.
4.1 4.12 Thermomètre, permettant d'effectuer des mesures
entre 90 et 110 OC avec une précision de f 0.2 OC.
4.2 Burettes, de capacité :
4.13 Bain d'eau, chauffé au gaz ou à l'électricité, contrôlé
5 ml graduée en 0,02 ml;
par un thermostat, d'une capacité suffisante pour contenir
-
1 litre de liquide par fiole utilisée lors de l'essai et pouvant sup-
2 ml ou 1 ml, graduée en 0,Ol ml.
porter le cycle de chauffage spécifié au chapitre 6.
La capacité de la burette doit être choisie en fonction de la
quantité présumée de la solution d'acide chlorhydrique (3.2)
Dimensions approximatives
utilisée.
en millimètres
Pipettes, de capacité 25 ml, satisfaisant aux spécifica-
4.3
tions de la classe A de I'ISO 648.
4.4 Fioles jaugées, de capacité 50 ml, satisfaisant aux spé-
cifications de la classe A de 1'1S0 1042, en verre à haute résis-
tance chimique et munies de bouchons rodés. II est préférable
de choisir des fioles jaugées ayant un trait repère situé sur la
moitié inférieure du col. Avant utilisation, chaque fiole neuve
doit être prétraitée en la remplissant d'eau au-dessus du trait
repère et en la traitant trois fois en suivant le mode de chauf-
fage indiqué au chapitre 6, en renouvelant l'eau à chaque fois.
NOTE ~ Les fioles en silice peuvent également être utilisées, dans ce
cas, le prétraitement n'est pas nécessaire.
4.5 Fioles coniques, de capacité 100 ml, satisfaisant aux
spécifications de 1'1S0 1773. Des fioles neuves doivent
...