ISO 6868:2026
(Main)Workplace air — Quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction methods
- Abstract
This document specifies three methods for quantitative measurement of crystalline silica (CS) major polymorphs (quartz and cristobalite) mass percentage content in bulk samples using X-ray powder diffraction (XRPD). This document also provides general information about the capabilities and limitations of relevance to laboratories working for routine testing. Only X-ray diffractometers with Bragg-Brentano geometry are considered. XRPD techniques are used to characterize specimens in the form of loose powders, where the median grain size is between 1 μm and 10 μm physical diameter. Block specimens are not considered. Although a number of methods of analysis are considered in this document, other XRPD methods of analysis can be considered if they are demonstrated to give equivalent results.
- Status
- Published
- Publication Date
- 11-Aug-2026
- Technical Committee
- ISO/TC 146/SC 2 - Workplace atmospheres
- Drafting Committee
- ISO/TC 146/SC 2/WG 7 - Silica
- Current Stage
- 6060 - International Standard published - 60 Publication
- Start Date
- 12-Aug-2026
- Due Date
- 12-Dec-2025
- Completion Date
- 12-Dec-2025
Buy Documents
ISO 6868:2026 - Workplace air — Quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction methods
ISO 6868:2026 - Air des lieux de travail — Détermination quantitative du quartz et de la cristobalite dans les matériaux en vrac par des méthodes de diffraction des rayons X sur poudre
ISO 6868:2026 is an International Standard from ISO for the quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction (XRPD). It specifies three XRPD methods for measuring the mass percentage of these crystalline silica (CS) polymorphs in bulk samples, and it is written for laboratories doing routine testing. The document also describes the capabilities and limitations of the methods, with Bragg-Brentano geometry and loose powder specimens in scope.
What does ISO 6868:2026 specify?
ISO 6868:2026 covers quantitative XRPD measurement of quartz and cristobalite in bulk samples. It focuses on loose powders with a median grain size between 1 μm and 10 μm physical diameter, uses only X-ray diffractometers with Bragg-Brentano geometry, and excludes block specimens.
ISO 6868:2026 is organized into clauses on scope, references, terms, principle, equipment, sampling, specimen preparation, analysis, performance characteristics and reporting. It also includes five informative annexes that support identification, interference assessment, sample treatment, worked examples and method equivalency.
| Annex | What it covers |
|---|---|
| Annex A | Expected line positions and relative intensities of quartz and cristobalite |
| Annex B | Interferences on quartz and cristobalite diffraction patterns |
| Annex C | Sample treatment strategies |
| Annex D | Examples of analyses |
| Annex E | Examples of equivalency of the methods and between laboratory precision |
What are the key requirements of ISO 6868:2026?
Sampling and sample information
ISO 6868:2026 requires the bulk sample to be representative of the material being assessed, and sampling is to follow ISO 14488. In practice, the laboratory needs enough information about how the sample was collected, what phases may be present, and whether the material is natural or processed, because these factors affect interference and method choice.
If the results may have legal implications, the document expects standard procedures for collection and processing to be used and the target quantitative level to be agreed with the laboratory in advance. That matters because the chosen method and the sample mass both depend on the likely quartz or cristobalite content.
Specimen preparation is critical
ISO 6868:2026 treats specimen preparation as one of the most critical steps in the analysis. The sample is reduced to a loose powder, then prepared either as a specimen of infinite thickness in a holder or as a thin layer deposited on a filter.
The document allows crushing, grinding, drying, pre-concentration and removal of interfering phases before analysis. In practice, the laboratory has to preserve the sample as faithfully as possible while also making it suitable for XRPD measurement, because poor preparation can change intensity, broaden peaks or hide the crystalline silica signal.
Grinding and particle size must suit XRPD
ISO 6868:2026 expects the grain size to be fine enough for quantitative XRPD and warns that excessive grinding can amorphize quartz and cristobalite. It also notes that contamination from grinding equipment can matter when the crystalline silica content is very low.
The document prefers laboratory mills over hand grinding for producing suitable particle sizes. This matters because the intensity of the diffraction peaks depends on how many crystallites are actually sampled by the beam, so the particle size distribution of the unknown specimen should be comparable with that of the reference material or internal standard.
Two specimen types are used
ISO 6868:2026 uses two specimen types: specimens of infinite thickness mounted in a holder, and thin layer specimens deposited on filters. Thin layer specimens are prepared from a representative powder fraction on a 25-mm filter, and this route is linked to the external standard method.
For infinite thickness specimens, the document describes back packing in a holder and, when needed, the addition of reference material for the internal standard or spiking methods. In practice, the reader must choose the specimen type that matches the analytical method and the sample matrix.
Three quantitative methods are covered
ISO 6868:2026 specifies three quantitative methods: the external standard method, the internal standard method and the spiking method. The external standard method is for thin layer specimens on filters, the internal standard method is for infinite thickness specimens, and the spiking method is for infinite thickness specimens with quartz contents below approximately 20 %, depending on the matrix.
The document also requires preliminary qualitative identification of quartz and cristobalite from their diffraction pattern before quantification. This means the analyst does not go straight to calculation - the phase must first be recognized from its peaks and compared with reference patterns.
Instrument conditions and calibration are controlled
ISO 6868:2026 asks the analyst to choose suitable instrument settings such as tube material, power, slits, detector, monochromator, step size, scan range and time per step. At least five data points above half maximum are needed for each line used for quantification.
For the external standard method, the document uses calibration filters and corrected intensities to build calibration lines. For practical work, that means the laboratory must establish and maintain its own calibrated response for the line or lines used, rather than relying on a generic setting.
Performance, reporting and records matter
ISO 6868:2026 requires limits of detection and quantification to be determined in each laboratory, because they depend on the method, instrument and settings. It also discusses uncertainty of measurement, and it links sampling uncertainty and weighing practice to other ISO documents.
The test report must identify the laboratory, method, diffractometer, reference materials, LOD, LOQ, estimated expanded uncertainty, sample identity, result, analyst and approving manager. The laboratory also archives the procedures, calibration curves, scans, reports and samples so results can be checked later.
What terms does ISO 6868:2026 define?
- Crystalline silica (CS) - In this document, CS means the two main polymorphs quartz and cristobalite.
- X-ray powder diffraction (XRPD) - The diffraction method used here to identify and quantify quartz and cristobalite from powder patterns.
- Bragg-Brentano geometry - The reflection geometry of the diffractometer required by this standard.
- Specimen of infinite thickness - A specimen thick enough that increasing thickness no longer changes the diffracted intensity in practice.
- Thin layer specimen - A powder specimen deposited on a filter for analysis by the external standard method.
- Diffraction line - The peak, reflection or Bragg reflection in the diffraction pattern used for identification and quantification.
- Phase - The crystallographic phase of the material being measured.
- Limit of detection and limit of quantification (LOD and LOQ) - The smallest mass fractions that can be detected and reliably quantified.
Who uses ISO 6868:2026?
ISO 6868:2026 is used by analytical laboratories, occupational hygiene laboratories, and quality or technical teams that need to measure quartz or cristobalite in bulk materials. It is relevant to work involving workplace air exposure assessment, especially where bulk materials may generate respirable dust during handling.
The document also fits industries and materials such as mining, tunnelling, excavation, earth moving, drilling, construction materials, soils, rocks, minerals, waste, slurries, muds and chemicals classified under GHS. In practice, users apply it for routine testing, exposure-related investigations, product characterization, and support for risk management measures.
Which standards are used with ISO 6868:2026?
- ISO 14488 - Gives the sampling and sample splitting approach used for particulate materials.
- ISO 18158 - Supplies workplace air terminology used in the document.
- ISO 24095 - Provides guidance on calculating uncertainty for respirable CS measurements and can be used to support bulk sample uncertainty work.
- ISO 11648 - Gives guidance on estimating variance and checking precision and bias in bulk materials.
- ISO 15767 - Gives recommendations for weighing procedure and weighing uncertainty for filter-based specimens.
- ISO 7708 - Supplies the respirable convention referenced when discussing dust exposure and grain size context.
- ISO 13317-2, ISO 13317-3, ISO 13319-1 and ISO 13320 - Give particle size distribution methods that can be used to check grinding results.
- EN 13925-1 and EN 13925-2 - Supply diffraction terminology and the definition of infinite thickness.
- EN 17289-3 - Is cited for sedimentation-based selection of a desired grain size fraction.
- ISO/IEC Guide 98-3 - Is referenced for uncertainty of measurement principles.
What does the ISO 6868:2026 document contain?
ISO 6868:2026 contains the measurement principle, equipment lists, sampling rules, specimen-preparation steps and the three analytical routes for quartz and cristobalite. It also gives line-profile parameters, instrument-condition guidance, calibration and calculation approaches, and performance topics such as detection, quantification, uncertainty and equivalency.
The annexes add practical material that users can apply directly: expected line positions and relative intensities, interference maps for common minerals, treatment strategies to remove interfering phases, and complete worked examples for the external standard, internal standard and spiking methods. It also includes a filtration apparatus example, a back-filling specimen-preparation example, and an example diffraction-line profile to support routine laboratory implementation.
Buy Documents
ISO 6868:2026 - Workplace air — Quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction methods
ISO 6868:2026 - Air des lieux de travail — Détermination quantitative du quartz et de la cristobalite dans les matériaux en vrac par des méthodes de diffraction des rayons X sur poudre
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
ISO 6868:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Workplace air — Quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction methods". This standard covers: This document specifies three methods for quantitative measurement of crystalline silica (CS) major polymorphs (quartz and cristobalite) mass percentage content in bulk samples using X-ray powder diffraction (XRPD). This document also provides general information about the capabilities and limitations of relevance to laboratories working for routine testing. Only X-ray diffractometers with Bragg-Brentano geometry are considered. XRPD techniques are used to characterize specimens in the form of loose powders, where the median grain size is between 1 μm and 10 μm physical diameter. Block specimens are not considered. Although a number of methods of analysis are considered in this document, other XRPD methods of analysis can be considered if they are demonstrated to give equivalent results.
This document specifies three methods for quantitative measurement of crystalline silica (CS) major polymorphs (quartz and cristobalite) mass percentage content in bulk samples using X-ray powder diffraction (XRPD). This document also provides general information about the capabilities and limitations of relevance to laboratories working for routine testing. Only X-ray diffractometers with Bragg-Brentano geometry are considered. XRPD techniques are used to characterize specimens in the form of loose powders, where the median grain size is between 1 μm and 10 μm physical diameter. Block specimens are not considered. Although a number of methods of analysis are considered in this document, other XRPD methods of analysis can be considered if they are demonstrated to give equivalent results.
ISO 6868:2026 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 6868:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 block
- 3.2 specimen
- 3.3 phase
- 3.4 diffraction line
- 4 Principle
- 5 Equipment
- 5.1 Diffraction system
- 5.2 Balance
- 5.3 Reference materials
- 5.4 Equipment for the preparation of specimens of infinite thickness
- 5.5 Equipment for the preparation of thin thickness specimens
- 5.6 Equipment for sample treatment and reagents
- 6 Sampling
- 7 Specimen preparation
- 7.1 General
- 7.2 Crushing
- 7.3 Grinding
- 7.4 Drying
- 7.5 Pre-concentration and removal of interfering phases
- 7.6 Weighing and mounting of a specimen of infinite thickness
- 7.7 Weighing and deposition of thin layer specimen on filter
- 8 Analysis
- 8.1 Symbols
- 8.2 Parameters of a diffraction line profile
- 8.3 Instrument conditions
- 8.4 Analytical methods
- 9 Performance characteristics of the methods
- 9.1 Limits of detection and quantification
- 9.2 Uncertainty of measurement
- 9.3 Equivalency of the methods and between laboratory precision
- 10 Test report
- 10.1 Minimum report requirements
- 10.2 Data to be archived by the laboratory
- Annex A
- Annex B
- Annex C
- Annex D
- Annex E
- Bibliography
Introduction
Exposure to crystalline silica (CS) in the respirable fraction of inhaled airborne dust is a hazard to the health of workers in many industries. For this document, CS refers to the two most common polymorphs, quartz and cristobalite. To assess the exposure of an individual, personal samples of air are taken during a work activity, and then the amount of respirable CS is measured. In addition to the procedures for determining the airborne concentration of respirable CS in a workplace atmosphere, it can be useful, or required, to evaluate the CS content in bulk materials that have a potential risk of being respirable when they are ground or manipulated.
This document is appropriate for the analysis of material selected to be representative of a product, or soil, rock, mineral, waste, depending on the nature of the investigation. Bulk materials are generally in the solid state but can also be made by watery mixtures of insoluble matter (slurries, muds). A variety of origins, compositions, sizes and shapes, such as solid blocks, fragments, slabs, sand, powders and flours, can represent bulk materials.
The knowledge of CS content in natural rocks and soils is useful when, for example, assessing potential [1] exposure by inhalation of airborne dust meeting the respirable convention of ISO 7708 in work activities that involve excavation, earth moving, and drilling plant operations. Elevated exposures to respirable CS are often found in confined spaces, such as in mining and tunnelling. Knowing the mass fraction of CS in construction materials and natural rocks or soils contributes to the characterization of potential sources of airborne dust and allows planning of risk management measures in order to reduce potential exposures to airborne dust.
The methods in this document can also be used for the analysis of samples, which have been collected for the purpose of classification and labelling of chemicals according to the Globally Harmonized System (GHS), when a CS phase is found as a “substance”, or in “mixtures” and “articles”, as defined in the GHS. As is necessary in any good routine type analysis, especially where the results can have legal implications, it is useful to establish standard procedures for analysing the specimens. There are several methods mentioned in the literature for the determination of quartz, and many procedures can be developed, but no single procedure is applicable to all situations. Standardizing procedures for X-ray powder diffraction (XRPD) analysis of bulk materials, which are applicable to all materials, is difficult because of the variability of the matrices and their potential interferences. Therefore, the method chosen for the analysis should be carefully tested in the laboratory for the specific conditions. The problems of processing samples containing either quartz or cristobalite, or both is essentially the same as processing samples of bulk materials in general, and the major problem is preparing a specimen that is representative of the bulk material. The potential accuracy obtainable from a sub-sample or specimen of bulk material is related to the effective number of particles interrogated by the X-ray beam, which is related to the distribution of particles sizes and their absorption coefficients.
International Standard ISO 6868:2026(en) Workplace air — Quantitative determination of quartz and cristobalite in bulk materials by X-ray powder diffraction methods
1 Scope
This document specifies three methods for quantitative measurement of crystalline silica (CS) major polymorphs (quartz and cristobalite) mass percentage content in bulk samples using X-ray powder diffraction (XRPD). This document also provides general information about the capabilities and limitations of relevance to laboratories working for routine testing.
Only X-ray diffractometers with Bragg-Brentano geometry are considered. XRPD techniques are used to characterize specimens in the form of loose powders, where the median grain size is between 1 μm and 10 μm physical diameter. Block specimens are not considered.
Although a number of methods of analysis are considered in this document, other XRPD methods of analysis can be considered if they are demonstrated to give equivalent results.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 14488, Particulate materials — Sampling and sample splitting for the determination of particulate properties ISO 18158, Workplace air — Terminology
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 18158 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 block
self-adhering single piece of interconnected particles or crystallites [2] [SOURCE: EN 13925-1:2003, 3.2 ]
3.2 specimen
portion of the sample in the specific form used in the diffraction instrument for a given data collection process [2] [SOURCE: EN 13925-1:2003, 3.3 ]
ISO 6868:2026(en)
3.3 phase
crystallographic phase thermodynamic phase portion of a physical system sharing a common molecular and inter-molecular structure irrespective of any subdivision by size distribution or shape [2] [SOURCE: EN 13925-1:2003, 3.4 ]
3.4 diffraction line
peak reflection Bragg reflection region of the diffraction pattern containing an intensity maximum and corresponding to diffraction from a set of lattice planes [2] [SOURCE: EN 13925-1:2003, 3.5 ]
4 Principle
The experimental technique used in this document to determine the diffraction pattern of a specimen is the “angular dispersive technique”, where the X-rays are monochromatic and the measurement is made by scanning the diffraction angle. Diffractometers with Bragg-Brentano geometry working in reflection geometry are to be used with this document; transmission geometry is not considered. Two types of powder specimens are considered in relation to their thickness:
- specimens of “infinite thickness”;
- “thin layer” specimens deposited on filters.
NOTE “Infinite thickness” and “thin layer” are defined by the preparation steps in this document. Phase identification is a preliminary step in every quantitative phase analysis and provides information necessary to make a decision regarding the selection of procedure for quantitative analysis. The identification of both quartz and cristobalite in an unknown specimen by XRPD is based on visual or computer-assisted comparisons of portions of its X-ray powder pattern that should include at least two main peaks, compared to the experimental patterns of quartz and cristobalite reference materials. In quantitative phase analysis, the percentages by mass of quartz and cristobalite are determined based on the integrated intensities of one or more individual diffraction lines of each phase. These intensities are compared to the corresponding values from calibration specimens. Three methods are considered:
- external standard method, for thin layer specimens deposited on filters (comparison of the response obtained with the specimen to the response in a calibration line for quartz or cristobalite reference material, see 8.4.4);
- internal standard method, for specimens of infinite thickness (addition of a known amount of a crystalline phase material that has been shown not present in the original sample, see 8.4.5);
- spiking method, also known as standard addition method, for specimens of infinite thickness and quartz contents below approximately 20 %, depending on the matrix (addition of a known amount of quartz or cristobalite to the sample being studied, see 8.4.6).
Multiple methods applied to a single sample can be used to verify analyses. Whole powder pattern analysis and standard free methods (e.g. the Rietveld method) are not considered in this document.
ISO 6868:2026(en)
5 Equipment
5.1 Diffraction system
5.1.1 Diffractometer
This document has been prepared to be used with a diffractometer employing the Bragg-Brentano parafocusing geometry, where the specimen and the receiving slit all lay on the focusing circle. The vertical θ:θ or θ:2θ configurations are most advantageous for handling powder specimens. A diffractometer generally comprises:
- goniometer;
- X-ray source that includes a line-voltage supply, a high-voltage generator and a X-ray tube; a conventional X-ray sealed tube source is often used and the most commonly used tube anode material is copper;
- incident beam optics, that can include monochromatisation or filtering, collimation and focusing or parallelism of the beam;
- specimen stage; the specimen is contained in a specimen holder, which is constructed to allow specimen rotation around the appropriate axis;
- diffracted beam optics, that can include monochromatisation or filtering, collimation and focusing or parallelism of the beam;
- detector;
- data collection system.
Procedures for instrument alignment and performance characterisation of Bragg-Brentano diffractometers [3] are given in EN 13925-3 .
5.1.2 Specimen holders
Several types of specimen holders can be used for diffraction analysis. The following standard circular specimen holders are recommended when the analytical methods described in this document are used. - Specimen holder for loose powder with cavity mount; top, back or side loaded. For back-loading of powder, a specimen holder consists of a bottom plate, which supports the powder, and a ring. The diameter of the cavity to be filled generally varies between 15 mm and 30 mm, and the powder thickness is a minimum of 1 mm (for infinite thickness specimen).
- Specimen holder for 25-mm filter (for thin layer specimen), where the support base of the filter, or the filter itself, is a disc made of a metal (e.g. silver, zinc or aluminium).
5.2 Balance
A microbalance capable of weighing ±1 μg or better over the range 0 g to 5 g is required for the preparation of specimens deposited on 25-mm filters (thin layer). For the preparation of specimens of infinite thickness, by mixing of powders, the materials should be weighed in glass weighing bottles with lids; capacities of 5 ml to 15 ml are generally required, so that the total mass exceeds 5 g, therefore, the balance operational range should span up to 20 g, and an analytical sensitivity of 10 μg is sufficient. An electrostatic eliminator is needed when weighing.
5.3 Reference materials
5.3.1 Quartz and cristobalite
Pure quartz and cristobalite reference materials with a median size of particles in the range 1 μm to 10 μm, preferably smaller than 5 μm, and similar to the median size of particles in the specimens, are to be used.
ISO 6868:2026(en) Reference materials can be prepared in the laboratory from pure quartz and cristobalite crystals, if the correct particle size is achieved and phase purity is characterized. NOTE United States National Institute of Science and Technology (NIST) have developed Standard Reference Materials (SRM’s) for respirable quartz (1878 series) and respirable cristobalite (1879 series) with certified phase 1) purity.
5.3.2 Internal standard
For the internal standard method, the chosen mineral phase should have a fully resolved diffraction line, not overlapping any lines of the CS phases, and free from microabsorption (i.e. be of very small particle size or have an absorption similar to the specimen) and extinction. Hence, it is essential that internal standard powder crystallite size be in the range 1 μm to 10 μm, preferably smaller than 5 μm, and similar to the median size of particles in the specimens. Internal standard, quartz and cristobalite reference materials are generally prepared in the laboratory from pure crystals milled until the optimum size range is reached. A sufficient amount of each reference material should be prepared, tested, stored and added to the specimens for analyses.
NOTE 1 The definition of “fully resolved” line is beyond the scope of this document. The experience of the analyst can guide in assessing and addressing this aspect of the analysis. NOTE 2 Grain size can be measured by using one of the techniques described in 7.3 NOTE 4, and purity characterized by XRPD.
NOTE 3 Corundum is a mineral phase often used as an internal standard. NIST SRM 676a is a corundum structure- 2) alumina powder intended primarily for use as an internal standard for quantitative determinations by XRPD.
5.3.3 XRD drift correction disc
An aluminium or silicon polycrystalline disc or another suitable robust material, should be used to correct for the drift in XRD radiation intensity over time.
3) NOTE The sintered alumina disc NIST SRM 1976b is frequently used.
5.4 Equipment for the preparation of specimens of infinite thickness
5.4.1 Laboratory drying oven
For ovens of the forced-draft type, the air circulation should not be so strong that any transport of particles can take place.
5.4.2 Masonry hammer, jaw crusher or similar device
Initial processing is often needed to reduce the material to the required size for milling. Fractionation (e.g. use of a masonry hammer or jaw crusher) of the material into smaller pieces can be performed dry, although processing involving a grinding rather than a crushing action should be performed ‘wet’ to reduce the potential for a deterioration of crystalline structure.
5.4.3 Laboratory mill
Several types of mechanical grinding devices, driven by a motor, can produce the required grinding action by freely moving milling pieces (i.e. balls and rods) in a cylindrical grinding chamber completely encapsulated. 1) This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the products named. Equivalent products may be used if they can be shown to lead to the same results. 2) This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results. 3) This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.
ISO 6868:2026(en) The device rotates at a given speed, and size reduction is achieved by impact and shear between the milling pieces, whose effectiveness is improved by vibration. Chamber and milling pieces made of the same material should be used. Hard materials such as tungsten carbide, silicon nitride, zirconium oxide and corundum are recommended, while agate should be avoided because of potential contamination. Grinding chambers can typically have volumes between 80 ml and 500 ml, and the material filling can generally range between 15 % and 50 % of the volume (the instruction of the manufacturer should be followed). A so-called “micronizing” mill can also be used. This mill generally uses corundum cylindrical grinding elements in a small airtight polypropylene jar that handle a sample volume of 4 ml (or 10 g). Wet grinding (water, 2-propanol or cyclohexane) is the preferred grinding method for a micronizing mill. NOTE The minimum quantity of material that can be ground is an important parameter. For example, if a 250 ml grinding chamber is used, a minimum filling of 30 ml is generally suggested. This minimum volume corresponds to a
mass of approximately 40 g for a fine sand sample of average density (2,6 g cm ). Therefore, if the sample mass is less than 40 g, it cannot be ground in the described chamber.
5.4.4 Other equipment
5.4.4.1 Mortar and pestle for hand grinding and mixing. They are manufactured out of many different materials, but hard mortar types such as boron carbide, are recommended, while agate can introduce contamination and should be avoided.
5.4.4.2 Preparation kit for mounting the powder in the specimen holder. The kit generally comprises a specimen “preparation table” onto which a specimen holder ring is clamped, a powder press block, and a spatula to remove the surplus powder (see 7.6).
5.4.4.3 Stainless steel test sieves used to verify fragments size before grinding them in the laboratory mill; a receiving pan is used to collect the passing material. NOTE Fragment sizes of less than 10 mm can generally be milled, but a smaller initial size improves the result of grinding. The use of a test sieve with aperture size between 2,0 mm to 2,8 mm is suggested when a ball or rod mill is used. If a “micronizing” mill is used, the sample can be passed through a 0,4 mm aperture sieve prior to grinding.
5.5 Equipment for the preparation of thin thickness specimens
5.5.1 Filters for analysis
Filters shall be of a 25 mm diameter. The filter types generally used for the XRPD analysis of CS, and their advantages and disadvantages, are listed in Table 1. These filter materials generally do not interfere with the measurement of the major reflections of quartz (101), (100), and (112), and cristobalite (101), (200 and 112), and (102). In any case, batches of filters should be tested to detect potential interferences, because impurities can be introduced during the filter manufacturing process. These tests are also useful to verify the background fluctuation levels, since they have an effect on the readability of diffraction peaks, worsening the limit of detection for CS. Silver filters exhibit the least variability and lowest background levels and thus are useful in situations where low limits of detection are required. However, cristobalite combined reflections (200 and 112) can sometimes be difficult to measure because they are located in the tail at the side of silver reflection (100). Silver and mixed esters of cellulose filters are rigid and easy to handle when weighing and loading in the sample holder. PVC and especially polycarbonate filters are flexible and require careful handling. A silver filter used for analysis allows an effective correction for absorption (see 8.4.4.3). When an organic filter with high or medium transparency to X-ray radiation (see Table 1) is used for analysis, an effective correction for absorption can still be carried out by measuring the intensity of a reflection of the underlying metallic (e.g. silver, zinc or aluminium) support base.
ISO 6868:2026(en) Table 1 — Examples of filters for CS analysis Background Mass absorption Interfering peak fluctuation correction b index a Filter material and pore size Quartz Cristobalite Quartz Filter transparency
index 101 100 112 101 200 102 101 100 Silver (Ag) 0,45 μm no no no no yes no 1 1 1 d Polyvinyl chloride (PVC) 5 μm no no no no yes no 1,5 1 0,72 Mixed esters of cellulose (MCE) d no no no no yes no 2,4 1,7 0,78 0,8 μm d Polycarbonate (PC) 0,4 μm no no no no yes no 1,3 2,2 0,98 Polytetrafluoroethylene (PTFE) d no yes no yes yes no 2,5 ND 0,74 0,5 μm a The analyst should be aware that for any filter pore size the recovery will possibly not be complete. b Background fluctuation index IF= /F where F and F are the standard deviations of XRD BF Bf,,ilterB Ag BA, g Bf, ilter intensities measured in the ranges of primary (Qz1) and secondary (Qz2) quartz peak profiles (Cu anode) on a blank silver filter, and on a blank filter of the material under testing placed on a silver filter, respectively. I =1 is used as a reference for silver BF filters.
...
Contents
- Introduction
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 bloc
- 3.2 échantillon (analysé)
- 3.3 phase
- 3.4 raie
- 4 Principe
- 5 Matériel
- 5.1 Système de diffraction
- 5.2 Balance
- 5.3 Matériaux de référence
- 5.4 Matériel pour la préparation d'échantillons d'épaisseur infinie
- 5.5 Matériel pour la préparation des échantillons de faible épaisseur
- 5.6 Matériel pour le traitement des échantillons et réactifs
- 6 Échantillonnage
- 7 Préparation de l’échantillon à analyser
- 7.1 Généralités
- 7.2 Concassage
- 7.3 Broyage
- 7.4 Séchage
- 7.5 Pré-concentration et élimination des phases interférentes
- 7.6 Pesée et mise en place d’un échantillon d'épaisseur infinie
- 7.7 Pesée et dépôt de l’échantillon à couche mince sur le filtre
- 8 Analyse
- 8.1 Symboles
- 8.2 Paramètres d'une raie de diffraction
- 8.3 Conditions de mesure de l’instrument
- 8.4 Méthodes d’analyse
- 9 Caractéristiques de performance des méthodes
- 9.1 Limites de détection et de quantification
- 9.2 Incertitude de mesure
- 9.3 Équivalence des méthodes et exactitude interlaboratoires
- 10 Rapport d’essai
- 10.1 Exigences minimales pour le rapport
- 10.2 Données à archiver par le laboratoire
- Annexe A
- Annexe B
- Annexe C
- Annexe D
- Annexe E
- Bibliographie
Introduction
L’exposition à la silice cristalline (SC) dans la fraction respirable de la poussière en suspension dans l’air inhalée présente un danger pour la santé des travailleurs de nombreuses industries. Pour les besoins du présent document, "SC" désigne les deux polymorphes les plus courants que sont le quartz et la cristobalite. Pour évaluer l’exposition d’une personne, des échantillons d’air individuels sont prélevés au cours d’une activité de travail, puis la quantité de SC alvéolaire est ensuite mesurée. En plus des procédures permettant de déterminer la concentration de la SC alvéolaire dans l’air en suspension dans l’atmosphère d'un lieu de travail, il peut être utile, voire exigé, d’évaluer la teneur en SC des matériaux en vrac qui présentent potentiellement le risque d’être respirés lorsqu’ils sont broyés ou manipulés. Le présent document s’applique à l’analyse d’un matériau sélectionné pour être représentatif d’un produit, d’un sol, d’une roche, d’un minéral ou d’un déchet, selon la nature de l’investigation. Les matériaux en vrac existent généralement à l’état solide, mais peuvent aussi être constitués de mélanges aqueux de matières insolubles (barbotines, boues). Les matériaux en vrac peuvent avoir une diversité d’origines, de compositions, de tailles et de formes, telles que des blocs solides, des fragments, des plaques, du sable, des poudres et des farines.
La connaissance de la teneur en SC des roches naturelles et des sols est utile, par exemple, lors de l’évaluation de l’exposition potentielle par inhalation de poussière en suspension dans l’air conformément à la convention [1] alvéolaire de l’ISO 7708 dans les activités de travail qui impliquent des opérations d’installations d’excavation, de terrassement et de forage. Des expositions élevées à la SC alvéolaire sont souvent détectées dans les espaces confinés, tels que dans les mines et les tunnels. Le fait de connaître la fraction massique de SC dans les matériaux de construction et les roches ou sols naturels contribue à la caractérisation des sources potentielles de poussière en suspension dans l’air et permet de planifier des mesures de gestion des risques afin de réduire l’exposition potentielle à la poussière en suspension dans l’air. Les méthodes décrites dans le présent document peuvent également être utilisées pour l’analyse d’échantillons, qui ont été collectés à des fins de classification et d’étiquetage des produits chimiques conformément au Système général harmonisé (SGH), lorsqu’une phase de SC est trouvée sous forme de "substance", ou dans des "mélanges" et des "articles", tels que définis dans le SGH. Comme cela est nécessaire dans toute bonne analyse de routine, notamment lorsque les résultats peuvent avoir des incidences juridiques, il est utile d’établir des procédures normalisées pour analyser les échantillons. La littérature technique mentionne plusieurs méthodes pour la détermination du quartz et de nombreuses procédures peuvent être élaborées, mais aucune procédure unique n’est applicable à toutes les situations. Il est difficile de normaliser des procédures pour l’analyse des matériaux en vrac par diffraction des rayons X sur poudre (XRPD), qui soient applicables à tous les matériaux, en raison de la variabilité des matrices et de leurs interférences potentielles. Par conséquent, il convient de soumettre la méthode choisie à des essais rigoureux en laboratoire dans les conditions spécifiques. Le problème lié au traitement d’échantillons contenant du quartz ou de la cristobalite, ou les deux, est pratiquement identique à celui du traitement des échantillons de matériaux en vrac en général, et le problème majeur réside dans la préparation d’un sous-échantillon qui soit représentatif du matériau en vrac. L’exactitude potentielle pouvant être obtenue à partir d’un sous-échantillon de matériau en vrac est liée au nombre effectif de particules détectées par le faisceau de rayons X, qui dépend de la distribution granulométrique des particules et de leurs coefficients d’absorption.
Norme internationale ISO 6868:2026(fr) Air des lieux de travail — Détermination quantitative du quartz et de la cristobalite dans les matériaux en vrac par des méthodes de diffraction des rayons X sur poudre
1 Domaine d’application
Le présent document spécifie trois méthodes de mesure quantitative du pourcentage de teneur en masse des principaux polymorphes (quartz et cristobalite) de la silice cristalline (SC) dans les échantillons en vrac, en utilisant la diffraction des rayons X sur poudre (XRPD). Ce document fournit également des informations générales sur les capacités et les limites de pertinence des laboratoires travaillant dans le cadre des essais de routine.
Seuls les diffractomètres à rayons X à géométrie de Bragg-Brentano sont pris en compte. Les techniques XRPD sont utilisées pour caractériser les échantillons se présentant sous forme de poudres libres, lorsque la granulométrie médiane est comprise entre 1 μm et 10 μm de diamètre physique. Les échantillons massifs ne sont pas étudiés.
Bien qu’un certain nombre de méthodes d’analyse soient considérées dans le présent document, d’autres méthodes d’analyse par XRPD peuvent être envisagées, sous réserve de démontrer qu’elles produisent des résultats équivalents.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y compris les éventuels amendements).
ISO 14488, Matériaux particulaires — Échantillonnage et division des échantillons pour la caractérisation des propriétés particulaires ISO 18158, Qualité de l’air — Terminologie
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de l’ISO 18158 ainsi que les suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
- IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
3.1 bloc
pièce massive composée de particules ou de cristallites agrégées [2] [SOURCE: EN 13925-1:2003, 3.2]
ISO 6868:2026(fr)
3.2 échantillon (analysé)
sous-échantillon portion d’échantillon tel qu’il va être utilisé sur le diffractomètre pour une procédure d’acquisition de données spécifique [2] [SOURCE: EN 13925-1:2003, 3.3, modifié — Le terme "prise d’essai" a été remplacé par "échantillon (analysé)" et "sous-échantillon".]
3.3 phase
phase cristallographique phase thermodynamique partie d’un système physique ayant une structure moléculaire et intermoléculaire commune quelle que soit sa distribution morphologique et granulométrique [2] [SOURCE: EN 13925-1:2003, 3.4]
3.4 raie
pic réflexion réflexion de Bragg région d’un diffractogramme contenant un maximum d’intensité et correspondant à la diffraction par une famille de plans cristallins [2] [SOURCE: EN 13925-1:2003, 3.5]
4 Principe
La technique expérimentale utilisée dans le présent document pour déterminer le diffractogramme d’un échantillon est la "technique de dispersion angulaire", dans laquelle les rayons X sont monochromatiques et la mesure est effectuée en balayant l'angle de diffraction. Les diffractomètres à géométrie de Bragg- Brentano travaillant en géométrie de réflexion doivent être utilisés avec le présent document; la géométrie de transmission n'est pas prise en compte.
Deux types d’échantillons de poudre sont examinés en ce qui concerne leur épaisseur:
- les échantillons à "épaisseur infinie";
- les échantillons à "couche mince" déposés sur des filtres.
NOTE Les termes "épaisseur infinie" et "couche mince" sont définis par les étapes de préparation dans le présent document.
L'identification des phases est une étape préliminaire à toute analyse quantitative des phases et fournit les informations nécessaires à la prise de décision concernant la sélection de la procédure d'analyse quantitative. L'identification du quartz et de la cristobalite dans un échantillon inconnu par XRPD repose sur des comparaisons visuelles ou assistées par ordinateur de parties de son diffractogramme de rayons X sur poudre qui devrait inclure au moins deux pics principaux, par rapport aux diffractogrammes expérimentaux des matériaux de référence de quartz et de cristobalite.
Dans l'analyse quantitative des phases, les pourcentages en masse de quartz et de cristobalite sont déterminés sur la base des intensités intégrées d'une ou plusieurs raies individuelles de chaque phase. Ces intensités sont comparées aux valeurs correspondantes des échantillons étalon. Trois méthodes sont décrites:
- méthode de l'étalon externe pour les échantillons à couche mince déposés sur des filtres (comparaison de la réponse de l'échantillon avec la réponse de la courbe d'étalonnage pour le matériau de référence de quartz ou de cristobalite, voir 8.4.4);
ISO 6868:2026(fr) - méthode de l'étalon interne, pour les échantillons d'épaisseur infinie (ajout d'une quantité connue d'un matériau en phase cristalline dont il a été démontré qu'il n'était pas présent dans l'échantillon d'origine, voir 8.4.5); - méthode de dopage, également appelée méthode des ajouts dosé", pour les échantillons d'épaisseur infinie et les teneurs en quartz inférieures à environ 20 %, en fonction de la matrice (ajout d'une quantité connue de quartz ou de cristobalite à l'échantillon étudié, voir 8.4.6). Plusieurs méthodes appliquées à un seul échantillon peuvent être utilisées pour vérifier les analyses. L'analyse du diffractogramme complet de la poudre et les méthodes de référence (méthode Rietveld, par exemple) ne sont pas examinées dans le présent document.
5 Matériel
5.1 Système de diffraction
5.1.1 Diffractomètre
Le présent document a été élaboré pour être utilisé avec un diffractomètre à géométrie de parafocalisation Bragg-Brentano, où l'échantillon et la fente de réception se situent toutes sur le cercle de focalisation. Les configurations θ:θ ou θ:2θ verticales sont les plus avantageuses pour la manipulation des échantillons de poudre. Un diffractomètre comporte généralement:
- un goniomètre;
- une source de rayons X qui comprend l'alimentation en tension, le générateur de haute tension et le tube à rayons X. Un tube scellé à rayons X conventionnel est souvent utilisé, et le matériau d'anode du tube le plus couramment utilisé est le cuivre;
- une optique de faisceau incident, qui peut comprendre la monochromatisation ou le filtrage, la collimation et la focalisation ou le parallélisme du faisceau;
- la platine porte-échantillon: l’échantillon est contenu dans un porte-échantillon, qui est conçu pour permettre une rotation de l'échantillon autour de l'axe approprié;
- une optique de faisceau diffracté, qui peut comprendre la monochromatisation ou le filtrage, la collimation et la focalisation ou le parallélisme du faisceau;
- un détecteur;
- un système d’acquisition de données.
Les procédures d'alignement des instruments et de caractérisation des performances des diffractomètres [3] de Bragg-Brentano sont décrites dans l’EN 13925-3 .
5.1.2 Porte-échantillon
Plusieurs types de porte-échantillons peuvent être utilisés pour l'analyse par diffraction. Les porteéchantillons circulaires standard suivants sont recommandés lorsque les méthodes d'analyse décrites dans le présent document sont utilisées.
- Porte-échantillons pour poudre libre avec cavité; chargement par le haut, l'arrière ou le côté. Pour le chargement de la poudre par l’arrière, un porte-échantillons se compose d'une plaque inférieure qui supporte la poudre, et d'un anneau. Le diamètre de la cavité à remplir varie généralement entre 15 mm et 30 mm, et l'épaisseur de la poudre est au minimum de 1 mm (pour un échantillon d'épaisseur infinie).
- Porte-échantillons pour filtre de 25 mm (pour les échantillons à couche mince), où la base de support du filtre, ou le filtre lui-même, est un disque en métal (argent, zinc ou aluminium, par exemple).
ISO 6868:2026(fr)
5.2 Balance
Une microbalance capable de peser ±1 μg ou offrant une meilleure précision sur la plage de 0 g à 5 g est requise pour la préparation d’échantillons déposés sur des filtres de 25 mm (couche mince). Pour la préparation d’échantillons d'épaisseur infinie, par mélange de poudres, il convient de peser les matériaux dans des flacons tarés en verre munis de couvercles; des capacités de 5 ml à 15 ml sont généralement requises, de sorte que la masse totale dépasse 5 g. Par conséquent, il convient que la plage opérationnelle de la balance s'étende jusqu'à 20 g, et une sensibilité analytique de 10 μg est suffisante. Un dispositif de neutralisation des charges électrostatiques est nécessaire lors de la pesée.
5.3 Matériaux de référence
5.3.1 Quartz et cristobalite
Il faut utiliser des matériaux de référence de quartz et de cristobalite purs dont la taille médiane des particules est comprise entre 1 μm et 10 μm, de préférence inférieure à 5 μm, et similaire à la taille médiane des particules contenues dans les échantillons. Les matériaux de référence peuvent être préparés en laboratoire à partir de cristaux de quartz et de cristobalite purs, à condition que la taille des particules obtenues soit correcte et que la pureté des phases soit caractérisée. NOTE L’Institut national américain des sciences et technologies (NIST) a élaboré des matériaux de référence normalisés (SRM) pour le quartz alvéolaire (série 1878) et la cristobalite alvéolaire (série 1879) avec une pureté de 1) phase certifiée .
5.3.2 Étalon interne
Pour la méthode de l'étalon interne, il convient que la phase minérale choisie présente une raie entièrement résolue, ne chevauchant aucune raie des phases de la SC et exempte de micro-absorption (c'est-à-dire qu'elle doit présenter des particules de très petite taille ou une absorption similaire à celle de l’échantillon) et d'extinction. Il est donc essentiel que la taille de la cristallite de la poudre de l’étalon interne soit comprise entre 1 μm et 10 μm, de préférence inférieure à 5 μm, et similaire à la taille médiane des particules contenues dans les échantillons. Les matériaux de référence pour l'étalon interne, le quartz et la cristobalite sont généralement préparés en laboratoire à partir de cristaux purs broyés jusqu'à ce que la classe granulométrique optimale soit atteinte. Il convient de préparer une quantité suffisante de chaque matériau de référence, puis de les soumettre à essai, de les stocker et de les ajouter aux échantillons à analyser. NOTE 1 La définition d’une raie "entièrement résolue" n’entre pas dans le domaine d’application du présent document. L'expérience de l'analyste peut l'aider à évaluer et traiter cet aspect de l'analyse. NOTE 2 La granulométrie peut être mesurée en utilisant l'une des techniques décrites en 7.3 NOTE 4, et la pureté peut être caractérisée par XRPD.
NOTE 3 Le corindon est une phase minérale souvent utilisée comme étalon interne. Le NIST SRM 676a est une poudre d'alumine à structure corindon principalement destinée à être utilisée comme étalon interne pour les 2) déterminations quantitatives par XRPD .
1) Cette information est donnée à l’intention des utilisateurs du présent document et ne signifie nullement que l’ISO approuve l’emploi du produit ainsi désigné. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils aboutissent aux mêmes résultats.
2) Cette information est donnée à l’intention des utilisateurs du présent document et ne signifie nullement que l’ISO approuve l’emploi du produit ainsi désigné. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils aboutissent aux mêmes résultats.
ISO 6868:2026(fr)
5.3.3 Disque de correction de la dérive XRD
Il convient d’utiliser un disque polycristallin en aluminium ou silicium, ou en tout autre matériau robuste adapté, pour corriger la dérive de l'intensité du rayonnement XRD au fil du temps. 3) NOTE Le disque d'alumine frittée NIST SRM 1976b est fréquemment utilisé.
5.4 Matériel pour la préparation d'échantillons d'épaisseur infinie
5.4.1 Étuve de laboratoire
Pour les étuves à tirage forcé, il convient que la circulation de l'air ne soit pas trop importante pour éviter le transport de particules.
5.4.2 Marteau de maçonnerie, concasseur à mâchoires ou dispositif similaire
Un traitement initial est souvent nécessaire pour réduire le matériau à la taille requise pour le broyage. Un fractionnement (à l'aide d'un marteau de maçonnerie ou d'un concasseur à mâchoires, par exemple) du matériau en plus petits morceaux peut être effectué à sec, bien qu’il convienne d’effectuer un traitement impliquant un broyage "en voie humide" plutôt qu'une action de concassage afin de réduire le risque de détérioration de la structure cristalline.
5.4.3 Broyeur de laboratoire
Plusieurs types de dispositifs de broyage mécanique, entraînés par un moteur, peuvent produire l'action de broyage requise en déplaçant librement des pièces de broyage (c'est-à-dire des billes et des tiges) dans une chambre de broyage cylindrique entièrement fermée. Le dispositif tourne à une vitesse donnée et la réduction de la taille est obtenue par impact et cisaillement entre les pièces de broyage, dont l'efficacité est améliorée par vibration. Il convient que le matériau de la chambre et des pièces de broyage soit identique. Les matériaux durs tels que le carbure de tungstène, le nitrure de silicium, l'oxyde de zirconium et le corindon sont recommandés, alors qu’il convient d’éviter l'agate en raison d'une contamination potentielle. Les chambres de broyage ont généralement un volume compris entre 80 ml et 500 ml, et le matériau de remplissage peut généralement représenter entre 15 et 50 % du volume de la chambre (il convient de respecter les instructions du fabricant). Un broyeur dit de "micronisation" peut également être utilisé. Ce broyeur utilise généralement des éléments de broyage cylindriques en corindon dans un petit pot en polypropylène étanche à l'air qui permet de traiter un volume d'échantillon de 4 ml (ou 10 g). Le broyage en voie humide (eau, 2-propanol ou cyclohexane) est la méthode de broyage préférée pour un broyeur de micronisation.
NOTE La quantité minimale de matériau qui peut être broyée est un paramètre important. Par exemple, si une chambre de broyage de 250 ml est utilisée, un remplissage minimum de 30 ml est généralement suggéré. Ce volume
minimal correspond à une masse d'environ 40 g pour un échantillon de sable fin de densité moyenne (2,6 g cm ). Par conséquent, si la masse de l'échantillon est inférieure à 40 g, il ne peut pas être broyé dans la chambre décrite.
5.4.4 Autre matériel
5.4.4.1 Mortier et pilon pour broyage et mélange manuels. Ils sont fabriqués à partir de nombreux
matériaux différents, mais les mortiers en matériaux durs, tels que le carbure de bore, sont recommandés, tandis que l'agate peut introduire une contamination et il convient donc de l’éviter. 5.4.4.2 Kit de préparation pour la mise en place de la poudre dans le porte-échantillons - Ce kit comprend généralement un "support de préparation" de l’échantillon sur laquelle un anneau porte-échantillons est serré, un bloc de compression de poudre et une spatule pour retirer l'excédent de poudre (voir 7.6). 3) Cette information est donnée à l’intention des utilisateurs du présent document et ne signifie nullement que l’ISO approuve l’emploi du produit ainsi désigné. Des produits équivalents peuvent être utilisés s’il est démontré qu’ils aboutissent aux mêmes résultats.
...