Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 003: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for enclosed applications - UV laser printable - Product standard

This European Standard specifies the characteristics of UV laser printable, tin plated copper conductor electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between - 65 °C and 135 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are for enclosed applications e.g. within equipment or conduit; they are only suitable for open airframe use when provided with additional protection against mechanical abuse. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Teil 003: Kupfer verzinnt - Betriebstemperaturen zwischen - 65 °C und 135 °C - Einfach extrudierte Isolierung für interne (geschützte) Verwendung - UV-Laser bedruckbar - Produktnorm

Diese Europäische Norm legt die Merkmale eines mit UV-Laser bedruckbaren, verzinnten Kupferleiters für
elektrische Leitungen der XLETFE-Familie zur Verwendung im elektrischen Bordnetz von Luftfahrzeugen bei
Betriebstemperaturen zwischen –65 °C und 135 °C, Betriebsspannungen mit einem Effektivwert von nicht
mehr als 600 V und Frequenzen von maximal 2 000 Hz fest. Diese Leitungen dienen zur Verwendung in
umschlossenen Anwendungen, z. B. in Geräten oder Elektroinstallationsrohren; sie sind nur zur Verwendung
in der offenen Zelle geeignet, wenn sie durch zusätzliche Schutzeinrichtungen vor mechanischer Beschädigung
geschützt sind. Bei Widersprüchen zwischen dieser Europäischen Norm und anderen zitierten Dokumenten
gelten die Anforderungen dieser Europäischen Norm.

Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 003 : Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil simple isolé pour applications internes - Marquable au laser UV - Norme de produit

La présente Norme Européenne spécifie les caractéristiques des conducteurs en cuivre étamé, marquables
au laser UV, de la famille des Copolymère Ethylène, Tétra Fluoro Ethylène Réticulé (XLETFE) utilisés dans
les systèmes électriques de bord des aéronefs à une température de fonctionnement comprise entre – 65 °C
et 135 °C, à une tension n’excédant pas 600 V eff. et une fréquence de 2 000 Hz. Ces câbles sont pour des
applications fermées par exemple à l'intérieur d'un équipement ou dans un conduit. Ils sont convenables pour
une utilisation ouverte sur la cellule seulement s'ils ont une protection mécanique supplémentaire. En cas de
conflit entre cette norme et un autre document de référence, les exigences de cette norme doivent être prises
en première considération.

Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina XLETFE - 003. del: Pocinjeni baker - Obratovalne temperature med -65 °C in 135 °C - Enojno ekstrudirana izolacija za notranjo uporabo - Možnost UV-laserskega tiskanja - Standard za izdelek

Ta evropski standard določa lastnosti električnih kablov, potiskljivih z UV-laserjem, z vodnikom iz pocinjenega bakra iz družine kopolimerov, pridobljenih z mrežno polimerizacijo etilena in tetrafluoretilena (XLETFE), za uporabo v električnih sistemih na krovu letal pri obratovalnih temperaturah med –65 in 135 °C, obratovalnih napetostih, ki ne presegajo efektivne vrednosti 600 V, ter frekvencah, ki ne presegajo 2000 Hz. Ti kabli so namenjeni za notranjo uporabo, npr. kot del opreme ali cevi; za odprto uporabo na ogrodjih letal so primerni samo, če so opremljeni z dodatno zaščito proti mehanski obrabi. V primeru neskladja med tem standardom in drugimi navedenimi dokumenti imajo prednost določila tega standarda.

General Information

Status
Withdrawn
Publication Date
01-Apr-2012
Withdrawal Date
02-Jan-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
24-Dec-2018
Due Date
16-Jan-2019
Completion Date
03-Jan-2019

Relations

Buy Standard

Standard
EN 4611-003:2012
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.ODVHUVNHJDLuft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Teil 003: Kupfer verzinnt - Betriebstemperaturen zwischen - 65 °C und 135 °C - Einfach extrudierte Isolierung für interne (geschützte) Verwendung - UV-Laser bedruckbar - ProduktnormSérie aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 003 : Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil simple isolé pour applications internes - Marquable au laser UV - Norme de produitAerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 003: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Single extruded wall for enclosed applications - UV laser printable - Product standard49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4611-003:2012SIST EN 4611-003:2012en,fr,de01-maj-2012SIST EN 4611-003:2012SLOVENSKI
STANDARD



SIST EN 4611-003:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4611-003
February 2012 ICS 49.060 English Version
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 003: Tin plated copper - Operating temperatures, between -65 °C and 135 °C - Single extruded wall for enclosed applications - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 003 : Cuivre étamé - Températures de fonctionnement comprisesentre - 65 °C et 135 °C - Fil simple isolé pour applications internes - Marquable au laser UV - Norme de produit
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Teil 003: Kupfer verzinnt - Betriebstemperaturen zwischen -65 °C und 135 °C - Einfach extrudierte Isolierung für interne (geschützte) Verwendung - UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 17 September 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4611-003:2012: ESIST EN 4611-003:2012



EN 4611-003:2012 (E) 2 Contents Page Foreword .31 Scope .42 Normative references .43 Terms, definitions, symbols and abbreviations .44 Materials and construction .54.1 Materials .54.2 Construction .54.3 Number of cores .64.4 Colour coding of cores .65 Required characteristics .66 Quality assurance . 107 Designation . 108 Identification and marking . 109 Packaging, labelling and delivery lengths . 1010 Technical specification . 10 SIST EN 4611-003:2012



EN 4611-003:2012 (E) 3 Foreword This document (EN 4611-003:2012) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2012, and conflicting national standards shall be withdrawn at the latest by August 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 4611-003:2012



EN 4611-003:2012 (E) 4 1 Scope This European Standard specifies the characteristics of UV laser printable, tin plated copper conductor electrical cables, Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family, for use in the on-board electrical systems of aircraft operating at temperatures between –65 °C and 135 °C, operating at voltages not exceeding
...