SIST CLC/R 013-001:2002
(Main)Electricity metering - Local and remote data exchange - Applications and performance (IEC/TR3 61361:1995)
Electricity metering - Local and remote data exchange - Applications and performance (IEC/TR3 61361:1995)
Corresponding IEC 61361:1995 already withdrawn
Lecture des compteurs électriques - Echanges de données local et à distance - Applications et performance
Cette publication donne des exemples d'exigences de performance concernant l'échange de données local et à distance entre les distributeurs et leurs clients à l'aide de communications bidirectionnelles. Les exigences de performance fournissent des informations aux distributeurs pour la spécification de systèmes satisfaisant leurs exigences. Les principes peuvent s'appliquer aussi au comptage de la chaleur, de l'eau et du gaz.
Electricity metering - Local and remote data exchange - Applications and performance (IEC/TR3 61361:1995)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST CLC/R 013-001:2002
Electricity metering - Local and remote data exchange - Applications and
performance (IEC/TR3 61361:1995)
Electricity metering - Local and remote data exchange - Applications and performance
Lecture des compteurs lectriques - Echanges de donnes local et distance - Applications
et performance
Ta slovenski standard je istov
...
This May Also Interest You
IEC 62057-1:2023 applies to stationary meter test units (MTUs) permanently installed in laboratories, used for testing and calibration of electricity meters, in particular for their type test, acceptance test and verification test. It covers the requirements for automatic MTUs for indoor laboratory application and applies to newly manufactured MTUs to test electricity meters on 50 Hz or 60 Hz networks with an AC voltage up to 600 V (phase to neutral).
If meters are intended for system voltages not specified in this document, special requirements are agreed between the manufacturer and the purchaser.
This document also defines the kind of tests to perform as type tests / routine tests / acceptance tests and commissioning tests for MTUs.
It does not apply to:
• portable reference meters and portable sources;
• electricity meters;
• data interfaces to the meter and test procedures of data interface;
• transformer operated MTUs;
• personal computers supplied together with the MTU.
- Standard80 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62052-41:2022 applies only to newly manufactured multi-energy and/or multi-rate static meters and it applies to their type tests only.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on networks with voltage up to 1 000 V AC, or 1 500 V DC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated displays;
• operate with detached indicating displays, or without an indicating display;
• be installed in a specified matching socket or rack;
• optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with Low Power Instrument Transformers (LPITs as defined in the IEC 61869 series) may be tested for compliance with this document and the relevant IEC 62053 series documents only if such meters and their LPITs are tested together as directly connected meters.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC, or 1 500 V DC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series of standards) when tested without such transformers;
• metering systems comprising multiple devices (except for LPITs) physically remote from one another;
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 62055 applies to newly manufactured, static watt-hour payment meters of
accuracy classes 0,5, 1 and 2 for direct connection, for the measurement of alternating current
electrical energy consumption of a frequency in the range 45 Hz to 65 Hz that include a supply
control switch for the purpose of interruption or restoration of the electricity supply to the load
in accordance with the current value of the available credit maintained in the payment meter. It
does not apply to static watt-hour payment meters where the voltage across the connection
terminals exceeds 1 000 V (line-to-line voltage for meters for polyphase systems).
It applies to payment meters for indoor application, operating under normal climatic conditions
where the payment meter is mounted as for normal service (i.e. together with a specified
matching socket where applicable).
Payment meters are implementations where all the main functional elements are incorporated
in a single enclosure, together with any specified matching socket. There are also multi-device
payment metering installations where the various main functional elements, such as the
measuring element, the user interface unit, token carrier interface, and the supply control switch
are implemented in more than one enclosure, involving additional interfaces.
Functional requirements that apply to payment meters are also defined in this document, and
include informative basic functional requirements and tests for the prepayment mode of
operation in Annex A. Allowances are made for the relatively wide range of features, options,
alternatives, and implementations that may be found in practice. The diverse nature and
functionality of payment meters prevent the comprehensive specification of detailed test
methods for all of these requirements. However, in this case, the requirements are stated in
such a way that tests can then be formulated to respect and validate the specific functionality
of the payment meter being tested.
This document does not cover specific functionality or performance requirements for circuit
protection, isolation or similar purposes that may be specified through reference to other
specifications or standards. Safety requirements removed from Edition 1.0 have been replaced
with references to the safety requirements now contained in IEC 62052-31:2015, the product
safety standard for newly manufactured electricity meters. In-service safety testing (ISST) is
not covered by IEC 62052-31:2015 and is left to national best practice usually as an extension
of existing in-service testing (IST) of metrology stability.
This document does not cover software requirements. This document covers type-testing
requirements only. For acceptance testing, the requirements given in IEC 62058‑11:2008 and
IEC 62058-31:2008 may be used.
Dependability aspects are addressed in the IEC 62059 series of standards. Additional reliability,
availability, maintenance and life cycle aspects are provided by IEC TC 56.
This document does not cover conformity tests and system compliance tests that may be
required in connection with legal or other requirements of some markets
- Standard57 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies a token generation mechanism and token structure for smart
prepayment functionality in markets where IEC 62055-41 compliant systems are not used, and
where a different security mechanism is required by project-specific or national requirements.
This document specifies token structure, authentication and an anti-replay mechanism, token
operating model, and protocol.
This document is informed by the STS Association key management services, and by the key
management mechanisms used within the DLMS/COSEM security model within IEC 62056‑6‑2.
Reference is made to the international STS token standards (IEC 62055-41, IEC 62055-51 and
IEC 62055-52) for payment metering systems, and interworking has been considered where
appropriate in terms of token carrier ranges in the decimal domain. IEC 62055-41 tokens and
those described in this document are not interoperable, however their domains are designed to
be mutually exclusive to ensure the two kinds of tokens do not interfere with each other.
Metering application processing and functionality, HAN interface commands and attributes,
WAN interface commands and attributes are outside the scope of this document; however,
reference is made to other standards in this regard.
The mechanism for auditing and retrieving data from the meter relating to tariffication, meter
readings, profile data and other legal metrology information is outside the scope of this
document; however, this is defined as part of any overall metering solution. Such interfaces for
retrieving data from a meter may be defined using suitable protocols such as DLMS/COSEM as
defined in the IEC 62056 series.
- Standard84 pagesEnglish languagesale 10% offe-Library read for×1 day
This document applies only to static watt-hour meters of accuracy classes A, B and C for the measurement of
alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests.
NOTE 1 For general requirements, such as construction, EMC, safety, dependability etc., see the relevant EN 62052
series or EN 62059 series.
This document applies to electricity metering equipment designed to:
— measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
NOTE 2 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal
voltages. See EN 62052-31:2016, Table 7. EN 62052-31:2016 covers AC voltages only up to 600 V and Ed. 2 of
EN IEC 62052-31 will cover AC voltages up to 1000 V.
— have all functional elements, including add-on modules, enclosed in, or forming a single meter case with
exception of indicating displays;
— operate with integrated or detached indicating displays;
— be installed in specified matching sockets or racks;
— optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with low power instrument transformers (LPITs as defined in the EN 61869
series) can be tested for compliance with this document only if such meters and their LPITs are tested together
and meet the requirements for directly connected meters.
NOTE 3 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude,
current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions;
delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions.
The relevant standards for these functions could apply in addition to the requirements of this document. However, the
requirements for such functions are outside the scope of this document.
NOTE 4 Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as
voltage magnitude, current magnitude, power, frequency, etc., are covered in EN 61557-12:2008. However, devices
compliant with EN 61557-12:2008 are not intended to be used as billing meters unless they are also compliant with the
EN IEC 62052-11:2021/A11:2022 and EN 50470-3:2022 standards.
NOTE 5 Product requirements for power quality instruments (PQIs) are covered in EN 62586-1:2017. Requirements for
power quality measurement techniques (functions) are covered in EN 61000-4-30:2015. Requirements for testing of the
power quality measurement functions are covered in EN 62586-2:2017.
This document does not apply to:
— meters for which the line-to-neutral voltage derived from nominal voltages exceeds 1 000 V AC;
— meters intended for connection with low power instrument transformers (LPITs as defined in the EN 61869
series) when tested without such transformers;
— metering systems comprising multiple devices (except of LPITs) physically remote from one another;
— portable meters;
NOTE 6 Portable meters are meters that are not permanently connected.
— meters used in rolling stock, vehicles, ships and airplanes;
— laboratory and meter test equipment;
reference standard meters;
— data interfaces to the register of the meter;
— matching sockets or racks used for installation of electricity metering equipment;
— any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise
meter’s performance (tampering).
NOTE 7 Nevertheless, specific tampering detection and prevention requirements, and test methods, as relevant for a
particular market are subject to the agreement between the manufacturer and the purchaser.
NOTE 8 Specifying requirements and test methods for fraud detection and prevention would be counterproductive, a
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Jul-2021
- 23-Aug-2022
- 17.220.20
- 91.140.50
- 2014/30/EU
- 2014/32/EU
- TP034
- M/541
- M/552
- MEE
This part of IEC 62052 specifies requirements and associated tests, with their appropriate conditions for type testing of AC and DC electricity meters. This document details functional, mechanical, electrical and marking requirements, test methods, and test conditions, including immunity to external influences covering electromagnetic and climatic environments.
- Amendment15 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Sep-2021
- 17-Aug-2022
- 17.220.20
- 91.140.50
- 2014/30/EU
- 2014/32/EU
- M/541
- M/552
- MEE
This part of IEC 62056 describes two sets of profiles: the first set of profiles allows a
bidirectional communication between a client and a server. This set of profiles is made of three
profiles allowing local bus data exchange with stations either energized or not. For nonenergized
stations, the bus supplies energy for data exchange. Three different profiles are
supported:
• base profile: this three-layer profile provides remote communication services;
NOTE 1 This first profile was published in IEC 61142:1993 and became known as the Euridis standard.
• profile with DLMS: this profile allows using DLMS services as specified in IEC 61334-4-41;
NOTE 2 This second profile was published in IEC 62056-31:1999.
• profile with DLMS/COSEM: this profile allows using the DLMS/COSEM Application layer and
the COSEM object model as specified in IEC 62056-5-3 and in IEC 62056-6-2 respectively.
The three profiles use the same physical layer and they are fully compatible, meaning that
devices implementing any of these profiles can be operated on the same bus. The transmission
medium is twisted pair using carrier signalling and it is known as the Euridis Bus.
The second set of profiles allows unidirectional communication between a given Energy
Metering device and a Customer Energy Management System. This second set is made up of
three profiles.
Subclause 4.2.1 to Clause 8 included specify the bidirectional communication using twisted pair
signalling and Clause 9 to 9.5 the unidirectional communication using twisted pair signalling.
- Standard129 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 62053 applies only to transformer operated static watt-hour meters of accuracy classes 0,1S, 0,2S and 0,5S for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Oct-2021
- 17.220.20
- 91.140.50
- 2014/30/EU
- M/552
- MEE
This part of IEC 62053 applies only to static var-hour meters of accuracy classes 0,5S, 1S, 1, 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Oct-2021
- 17.220.20
- 91.140.50
- 2014/30/EU
- M/552
- MEE
This part of IEC 62053 applies only to static watt-hour meters of accuracy classes 0,5, 1 and 2 for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Oct-2021
- 17.220.20
- 91.140.50
- 2014/30/EU
- M/552
- MEE
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.