SIST EN 1457:1999/AC:2006
(Amendment)Chimneys - Clay/Ceramic Flue Liners - Requirements and test methods
Chimneys - Clay/Ceramic Flue Liners - Requirements and test methods
TC - Various modifications throughout text
Abgasanlagen - Keramik-Innenrohre - Anforderungen und Prüfungen
Conduits de fumée - Conduits intérieurs en terre cuite/ceramique - Exigences et méthodes d'essai
Dimniki – Keramične tuljave – Zahteve in preskusne metode
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Chimneys - Clay/Ceramic Flue Liners - Requirements and test methodsConduits de fumée - Conduits intérieurs en terre cuite/ceramique - Exigences et méthodes d'essaiAbgasanlagen - Keramik-Innenrohre - Anforderungen und PrüfungenTa slovenski standard je istoveten z:EN 1457:1999/AC:2006SIST EN 1457:1999/AC:2006en,fr,de91.060.40Dimniki, jaški, kanaliChimneys, shafts, ductsICS:SIST EN 1457:1999/AC:19991DGRPHãþDSLOVENSKI
STANDARDSIST EN 1457:1999/AC:200601-oktober-2006
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1457:1999/ACMay 2006Mai 2006Mai 2006ICS 91.060.40English versionVersion FrançaiseDeutsche FassungChimneys - Clay/Ceramic Flue Liners - Requirements and test methodsConduits de fumée - Conduits intérieurs enterre cuite/ceramique - Exigences etméthodes d'essaiAbgasanlagen - Keramik-Innenrohre -Anforderungen und PrüfungenThis corrigendum becomes effective on 17 May 2006 for incorporation in the three official languageversions of the EN.Ce corrigendum prendra effet le 17 mai 2006 pour incorporation dans les trois versions linguistiquesofficielles de la EN.Die Berichtigung tritt am 17.Mai 2006 zur Einarbeitung in die drei offiziellen Sprachfassungen der ENin Kraft.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members.Tous droits d'exploitation sous quelque forme et de quelque manière que ce soit réservés dans le monde entier auxmembres nationaux du CEN.Alle Rechte der Verwertung, gleich in welcher Form und in welchem Verfahren, sind weltweit den nationalen Mitgliedernvon CEN vorbehalten.Ref. No.:EN 1457:1999/AC:2006 D/E/F
EN 1457:1999/AC:2006 (E/F/D) 2
English version
Foreword second paragraph last line, replace “July 1999“ by “January 2000“.
Table 1
line 16 Column 4 (Soot fire resistance)
Type of flue liner D1 N2 delete “No (O)” replace with “Yes (G)”
Table 1
line 17 Column 4 (Soot fire resistance)
Type of flue liner D1 N1 delete “No (O)” replace with “Yes (G)”
Table 1 line 18
Column 4 (Soot fire resistance)
Type of flue liner D2 N2 delete “Yes (G)” replace with “No (O)”
Table 1 line 19
Column 4 (Soot fire resistance)
Type of flue liner D1 N1 delete “Yes (G)” replace with “No (O)”
Sub-clause 9.1 first paragraph first line delete “16.8.2” replace with “16.8.3”
Sub-clause 9.1 second paragraph first line delete “16.8.2” replace with “16.8.3”
Sub-clause 9.2 in title at the end insert “(sootfire)”
Table 3
line 16 Column 2 (Test temperature)
Type of flue liner D1 N2 delete “250” replace with “1 000”
Table 3
line 17 Column 2 (Test temperature)
Type of flue liner D1 N1 delete “250” replace with “1 000”
Table 3
line 18 Column 2 (Test temperature)
Type of flue liner D2 N2 delete
“1 000” replace with “250”
Table 3
line 19 Column 2 (Test temperature)
Type of flue liner D2 N1 delete
“1 000” replace with “250”
Table 5
line 1 Column 3 (Type tests) delete “9.1” replace with “9.3”
Table 6
line 16 Column 2 (Test temperature)
Type of flue liner D1 N2 delete “250” replace with “1 000” and column 4 (Time to test……) delete “2,5” replace with “10”
Table 6
line 17 Column 2 (Test temperature)
Type of flue liner D1 N1 delete “250” replace with “1 000” and column 4 (Time to test……) delete “2,5” replace with “10”
Table 6
line 18 Column 2 (Test temperature)
Type of flue liner D2 N2 delete
“1 000” replace with “250” and column 4 (Time to test……) delete “10” replace with “2,5”
Table 6
line 19 Column 2 (Test temperature)
Type of flue liner D2 N1 delete
“1 000” replace with “250” and column 4 (Time to test……) delete “10” replace with “2,5”
Sub-clause 16.8.6
Line 2 delete “cross-sectional” replace with “surface”
Figure A.1
second statement on left hand side “RESUBMIT IF APPROPRIATE…………”
remove
arrowhead
from horizontal line drawn from the statement
Table ZA.1 Line 1
Column 2 “Requirement clauses in the standard” for intended use “Gas tightness/leakage” insert “9.2”
Table ZA.1 Line 4
Column 2 “Requirement clauses in the standard” for intended use “Resistance to fire” delete “9.3” insert “9.2”
EN 1457:1999/AC:2006 (E/F/D) 3 Version française
Avant-propos, deuxième paragraphe dernière ligne remplacer « juillet 1999 » par « janvier 2000 ».
Tableau 1 ligne 16 colonne 4 (résistance au feu de cheminée) Type de conduit D1 N2, remplacer « Non (O) » par « Oui (G) »
Tableau 1 ligne 17 colonne 4 (résistance au feu de cheminée) Type de conduit D1 N1, remplacer « Non (O) » pa
...