kSIST FprEN IEC 60215:201X/oprAA:2019
(Main)Safety requirements for radio transmitting equipment - General requirements and terminology
Safety requirements for radio transmitting equipment - General requirements and terminology
2019-03-15: SR to deliver CMs + Annex ZZ before end of March. Consultant assessment requested.
D161/014 : To be published with the main EN (PR= 25180)
Sicherheitsbestimmungen für Funksender - Allgemeine Anforderungen und Terminologie
Exigences de sécurité relatives aux matériels d'émission radioélectrique - Exigences générales et terminologie
Varnostne zahteve za radijsko oddajniško opremo - Splošne zahteve in terminologija - Dopolnilo AA
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
kSIST FprEN IEC 60215:201X/oprAA:2019
01-september-2019
Varnostne zahteve za radijsko oddajniško opremo - Splošne zahteve in
terminologija - Dopolnilo AA
Safety requirements for radio transmitting equipment - General requirements and
terminology
Sicherheitsbestimmungen für Funksender - Allgemeine Anforderungen und Terminologie
Exigences de sécurité relatives aux matériels d'émission radioélectrique - Exigences
générales et terminologie
Ta slovenski standard je istoveten z: FprEN IEC 60215:201X/prAA
ICS:
33.060.20 Sprejemna in oddajna Receiving and transmitting
oprema equipment
kSIST FprEN IEC en
60215:201X/oprAA:2019
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
---------------------- Page: 2 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
EUROPEAN STANDARD DRAFT
FprEN IEC 60215
NORME EUROPÉENNE
EUROPÄISCHE NORM
prAA
June 2019
ICS
English Version
Safety requirements for radio transmitting equipment - General
requirements and terminology
Exigences de sécurité relatives aux matériels d'émission Sicherheitsbestimmungen für Funksender - Allgemeine
radioélectrique - Exigences générales et terminologie Anforderungen und Terminologie
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2019-09-06.
It has been drawn up by CLC/SR 103.
If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 68767 Ref. No. FprEN IEC 60215:201X/FprAA E
---------------------- Page: 3 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
FprEN IEC 60215:201X/prAA:2019 (E)
1 Contents Page
2 European foreword . 3
3 1 Modification to Clause 2, “Normative references”. 4
4 2 Modifications to Clause 3, “Terms and definitions and symbols” . 5
5 3 Modifications to Clause 4, “Principle of safety” . 5
6 4 Modifications to Clause 5, “Operating conditions” . 5
7 5 Modifications to Clause 6, “Components and construction” . 6
8 6 Modifications to Clause 7, “Protection against harmful electric shock, and radio-
9 frequency skin burns” . 7
10 7 Modifications to Clause 8, “High temperature, fire and miscellaneous hazards” . 7
11 8 Modification to Annex A, “Clearance and creepage distances” . 9
12 9 Modifications to Annex C, “Guidance on safety precautions to be observed by personnel
13 working on radio” . 9
14 10 Modification to Annex ZA, "Normative references to international publications with their
15 corresponding European publications" . 9
16 11 Modifications to the “Bibliography” . 11
17
2
---------------------- Page: 4 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
FprEN IEC 60215:201X/prAA:2019 (E)
18 European foreword
19 This document (FprEN IEC 60215:201X/prAA:2019) has been prepared by CLC/SR 103 “Transmitting
20 equipment for radiocommunication”.
21 This document is currently submitted to the Enquiry.
22 The following dates are proposed:
• latest date by which the existence of this (doa) dor + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)
23 This document has been prepared under a mandate given to CENELEC by the European Commission and the
24 European Free Trade Association, and supports essential requirements of EU Directive(s).
25 For the relationship with EU Directive(s) see informative Annexes ZZA and ZZB, which are an integral part of
26 FprEN IEC 60215:201X.
3
---------------------- Page: 5 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
FprEN IEC 60215:201X/prAA:2019 (E)
27 1 Modification to Clause 2, “Normative references”
28 Replace all of the references in Clause 2 with the following:
29 IEC 60065:2014, Audio, video and similar electronic apparatus - Safety requirements
30 IEC 60068-2-1:2007, Environmental testing - Part 2-1: Tests - Test A: Cold
31 IEC 60112:2003+A1:2009, Method for the determination of the proof and the comparative tracking indices of
32 solid insulating materials
33 IEC 60244-6:1976, Methods of measurement for radio transmitters. Part 6: Cabinet radiation at frequencies
34 between 130 kHz and 1 GHz
35 IEC 60417:2002, Graphical symbols for use on equipment
36 IEC 60529:1989+A1:1999+A2:2013, Degrees of protection provided by enclosures (IP Code)
37 IEC 60695-1-10:2016, Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of
38 electrotechnical products - General guidelines
39 IEC 60695-1-11:2014, Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of
40 electrotechnical products - Fire hazard assessment
41 IEC 60825-1:2014, Safety of laser products - Part 1: Equipment classification and requirements
42 IEC 60825-12:2004, Safety of laser products - Part 12: Safety of free space optical communication systems
43 used for transmission of information
44 IEC 61000-2-2:2002+AMD1:2017+AMD2:2018, Consolidated version, Electromagnetic compatibility (EMC) -
45 Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-
46 voltage power supply systems
47 IEC 62232:2017, Determination of RF field strength, power density and SAR in the vicinity of
48 radiocommunication base stations for the purpose of evaluating human exposure
49 IEC 62311:2007, Assessment of electronic and electrical equipment related to human exposure restrictions for
50 electromagnetic fields (0 Hz - 300 GHz)
51 ISO 1999:2013, Acoustics – Estimation of noise-induced hearing loss
52 EN 50384:2002, Product standard to demonstrate the compliance of radio base stations and fixed terminal
53 stations for wireless telecommunication systems with the basic restrictions or the reference levels related to
54 human exposure to radio frequency electromagnetic fields (110 MHz - 40 GHz) – Occupational
55 EN 50385:2017, Product standard to demonstrate the compliance of base station equipment with
56 radiofrequency electromagnetic field exposure limits (110 MHz - 100 GHz), when placed on the market
57 ISO 7000:2014, Graphical symbols for use on equipment – Registered symbols
4
---------------------- Page: 6 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
FprEN IEC 60215:201X/prAA:2019 (E)
58 2 Modifications to Clause 3, “Terms and definitions and symbols”
59 In 3.1.12, replace the term definition with the following:
60 “equipment with BASIC INSULATION as provision for basic protection, and supplementary insulation as
61 provision for fault protection, or in which basic and fault protection are provided by REINFORCED
62 INSULATION”
63 In 3.2.3, replace the term definition with the following:
64 “IP codes (International Protection Marking, also known as Ingress Protection Marking) are used to indicate
65 the degree of protection against the intrusion of solid particles or water; the first digit of the code indicates the
66 protection against solid particles and the second digit the protection against ingress of water; where no
67 protection is specified for solid particles, this digit is replaced with the letter X.”
68 3 Modifications to Clause 4, “Principle of safety”
69 In 4.1, replace the second paragraph with the following:
70 “Designers shall take into account not only normal operating conditions of the equipment but also fault
71 conditions, reasonable foreseeable misuse and external influences such as temperature, altitude, pollution,
72 moisture and overvoltage on the mains supply. Dimensioning of insulation spacing should take account of
73 possible reductions by manufacturing tolerances, or where deformation could occur due to handling, shock
74 ageing and vibration likely to be encountered during manufacture, transport and normal use.”
75 In the fifth paragraph of 4.2, delete the following:
76 “The tests are neither mandatory nor limiting and may be modified by agreement between manufacturer and
77 purchaser.”
78 4 Modifications to Clause 5, “Operating conditions”
79 In the first paragraph of 5.2, replace
80 “a) The temperature and humidity conditions shall be compliant with the material specification as well as
81 within conditions agreed between manufacturer and purchaser.”
82 with:
83 “a) The temperature and humidity conditions shall be compliant with the material specification and shall be
84 within the following environmental conditions:
85 — temperature: +5 °C to +45 °C;
86 — relative humidity: 45 % to 75 %, without condensation;
87 — air pressure: 86 kPa to 106 kPa (860 mbar to 1 060 mbar).“
88 In the first paragraph of 5.2, replace:
89 “c) Where no specific environmental condition exists, the atmospheric conditions shall be within the following
90 range:
91 — temperature: +5 °C to +45 °C;
92 — relative humidity: 45 % to 75 %, without condensation;
93 — air pressure: 86 kPa to 106 kPa (860 mbar to 1 060 mbar).“
94 with:
5
---------------------- Page: 7 ----------------------
kSIST FprEN IEC 60215:201X/oprAA:2019
FprEN IEC 60215:201X/prAA:2019 (E)
95 “c) For differing conditions extra precautions shall be taken.”
96 In the first paragraph of 5.2, replace:
97 “e) For AC equipment, the waveform of the supply voltage shall be substantially sinusoidal.”
98 with:
99 “e) For AC equipment, the waveform of the supply voltage shall be substantially sinusoidal as defined in
100 IEC 61000-2-2:2002+AMD1:2017+AMD2:2018, Clause 4.3.”
101 In 5.3, replace:
102 “a) short circuits across CREEPAGE DISTANCES, if they are less than the values given in Annex A, unless
103 the insulation materials are resistant to tracking and non-flammable (for details see 7.6)”;
104 with:
105 “a) short circuits across CREEPAGE DISTANCES”;
106 In 5.3, replace:
107 “b) short circuits across CLEARANCES, if they are less than the values given in Annex A.”;
108 with:
109 “b) short circuits across CLEARANCES”;
110 In 5.3, replace:
111 “c) a potentially dangerous failure of any component as determined from inspecting the equipment and
112 studying the circuit diagram, unless the component is known to comply with an IEC test recommendation
113 appropriate to the conditions of use in the equipment”;
114 with:
115 “c) a potentially dangerous failure of any component as determined from inspecting the equipment and
116 studying the circuit diagram”;
117 In 5.4, delete the last paragraph:
118 “Partial deviated test conditions might be mutually agreed between purchaser and supplier.”
119 5 Modifications to Clause 6, “Components and construction”
120 In 6.2.1, delete the last two paragraphs:
121 “Components wh
...
Questions, Comments and Discussion