SIST EN IEC 61753-101-03:2022
(Main)Fibre optic interconnecting devices and passive components performance standard - Part 101-03: Fibre management systems for category OP - Outdoor protected environment (IEC 61753-101-03:2021)
Fibre optic interconnecting devices and passive components performance standard - Part 101-03: Fibre management systems for category OP - Outdoor protected environment (IEC 61753-101-03:2021)
This part of IEC 61753 contains the minimum tests, test severities and measurement
requirements which a fibre management system need to meet in order to be categorised as
meeting the IEC standard, category OP – Outdoor Protected environment, as defined in
IEC 61753-1.
This performance standard for fibre management systems defines the requirements for
standard optical performance under a set of specified conditions. It contains a series or a set
of tests and measurements with clearly stated conditions, severities and pass/fail criteria. The
series of tests, commonly referred to as an operating service environment or performance
category, is intended to be a basis to prove the product’s ability to satisfy the requirements of
a specific application, market sector or user group.
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil 101-3: Einzelfasermanagementsysteme für die Kategorie OP - Geschützte Freiluftanwendungen (IEC 61753-101-03:2021)
Norme de performance pour les dispositifs d’interconnexion et composants passifs fibroniques - Partie 101-03: Systèmes de gestion de fibres pour la catégorie OP - Environnement extérieur protégé (IEC 61753-101-03:2021)
IEC 61753-101-03:2021 contient les essais minimaux, ainsi que les sévérités d’essai et les exigences de mesure minimales auxquels il est nécessaire qu’un système de gestion de fibres satisfasse afin de pouvoir être classé comme satisfaisant à la norme IEC, Catégorie OP – Environnement extérieur protégé, telle qu’elle est définie dans l’IEC 61753-1. La présente norme de qualité de fonctionnement pour les systèmes de gestion de fibres définit les exigences de qualité de fonctionnement optique normalisée selon un ensemble de conditions spécifiées. Elle contient une série ou un ensemble d'essais et de mesurages avec des conditions, des sévérités et des critères d’acceptation/de rejet clairement définis. Les séries d'essais, auxquelles il est généralement fait référence en tant qu'environnement de service de fonctionnement ou en tant que catégorie de qualité de fonctionnement, sont destinées à constituer une base de démonstration de l'aptitude du produit à satisfaire aux exigences d'une application, d'un secteur de marché ou d'un groupe d'utilisateurs spécifiques.
Cette première édition annule et remplace l’IEC 61753-101-3, la première édition parue en 2006. Cette édition constitue une révision technique.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
a) les termes et définitions ont été mis à jour conformément à l’IEC 61753-1:2018 et à l’IEC 61756‑1:2019;
b) les sévérités d’essai ont été mis à jour conformément à l’IEC 61753-1:2018;
c) des essais matériels détaillés pour les moisissures (IEC 60068-2-10) et l'exposition à la lumière UV (ISO 4892-3) ont été ajoutés;
d) des exigences détaillées de qualité de fonctionnement du transport ont été supprimées;
e) des fibres de sous-catégorie B-657 (IEC 60793-2-50) pour les échantillons d’essai (Annexe A)ont été ajoutées.
Tehnični standard za optične spojne elemente in pasivne komponente - 101-03. del: Sistemi za upravljanje optičnih elementov za kategorijo OP - Zunanje zaščiteno okolje (IEC 61753-101-03:2021)
Ta del standarda IEC 61753 vsebuje minimalne zahteve glede preskusov, stopenj zahtevnosti preskusov in merjenja, ki jih mora izpolnjevati sistem za upravljanje optičnih elementov, da ustreza zahtevam kategorije OP v standardu IEC – Zunanje zaščiteno okolje, kot je opredeljeno v standardu IEC 61753-1.
Ta tehnični standard za sisteme za upravljanje optičnih elementov določa zahteve za standardno optično zmogljivost v določenih pogojih. Vsebuje niz oziroma nabor preskusov in meritev z jasno določenimi pogoji, stopnjami zahtevnosti in merili za uspešno/neuspešno opravljen preskus. Niz preskusov, ki se običajno imenuje operativno storitveno okolje ali kategorija učinkovitosti, je namenjen kot podlaga za dokazovanje, ali lahko izdelek izpolnjuje zahteve določenega načina uporabe, tržnega sektorja ali skupine uporabnikov.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN IEC 61753-101-03:2022
01-januar-2022
Nadomešča:
SIST EN 61753-101-3:2008
Tehnični standard za optične spojne elemente in pasivne komponente - 101-03.
del: Sistemi za upravljanje optičnih elementov za kategorijo OP - Zunanje
zaščiteno okolje (IEC 61753-101-03:2021)
Fibre optic interconnecting devices and passive components performance standard -
Part 101-03: Fibre management systems for category OP - Outdoor protected
environment (IEC 61753-101-03:2021)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil
101-3: Einzelfasermanagementsysteme für die Kategorie OP - Geschützte
Freiluftanwendungen (IEC 61753-101-03:2021)
Norme de performance pour les dispositifs d’interconnexion et composants passifs
fibroniques - Partie 101-03: Systèmes de gestion de fibres pour la catégorie OP -
Environnement extérieur protégé (IEC 61753-101-03:2021)
Ta slovenski standard je istoveten z: EN IEC 61753-101-03:2021
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
SIST EN IEC 61753-101-03:2022 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN IEC 61753-101-03:2022
---------------------- Page: 2 ----------------------
SIST EN IEC 61753-101-03:2022
EUROPEAN STANDARD EN IEC 61753-101-03
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2021
ICS 33.180.20 Supersedes EN 61753-101-3:2008 and all of its
amendments and corrigenda (if any)
English Version
Fibre optic interconnecting devices and passive components
performance standard - Part 101-03: Fibre management
systems for category OP - Outdoor protected environment
(IEC 61753-101-03:2021)
Norme de performance pour les dispositifs d'interconnexion Lichtwellenleiter - Verbindungselemente und passive
et composants passifs fibroniques - Partie 101-03: Bauteile - Betriebsverhalten - Teil 101-3:
Systèmes de gestion de fibres pour la catégorie OP - Einzelfasermanagementsysteme für die Kategorie OP -
Environnement extérieur protégé Geschützte Freiluftanwendungen
(IEC 61753-101-03:2021) (IEC 61753-101-03:2021)
This European Standard was approved by CENELEC on 2021-11-01. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61753-101-03:2021 E
---------------------- Page: 3 ----------------------
SIST EN IEC 61753-101-03:2022
EN IEC 61753-101-03:2021 (E)
European foreword
The text of document 86B/4497/FDIS, future edition 1 of IEC 61753-101-03, prepared by SC 86B
“Fibre optic interconnecting devices and passive components” of IEC/TC 86 “Fibre optics” was
submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN IEC 61753-101-03:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2022–08–01
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022–11–01
document have to be withdrawn
This document supersedes EN 61753-101-3:2008 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61753-101-03:2021 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60068-1 NOTE Harmonized as EN 60068-1
IEC 60332 (series) NOTE Harmonized as EN IEC 60332 (series)
IEC 60794-2 NOTE Harmonized as EN 60794-2
IEC 60794-3 NOTE Harmonized as EN 60794-3
IEC 61300 (series) NOTE Harmonized as EN 61300 (series)
2
---------------------- Page: 4 ----------------------
SIST EN IEC 61753-101-03:2022
EN IEC 61753-101-03:2021 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60068-2-10 - Environmental testing - Part 2–10: Tests - EN 60068-2-10 -
Test J and guidance: Mould growth
IEC 60721-3-1 - Classification of environmental conditions - EN IEC 60721-3-1 -
Part 3–1: Classification of groups of
environmental parameters and their
severities - Storage
IEC 60721-3-2 - Classification of environmental conditions - EN IEC 60721-3-2 -
Part 3–2: Classification of groups of
environmental parameters and their
severities – Transportation and handling
IEC 60793-2-50 - Optical fibres - Part 2–50: Product EN IEC 60793-2-50 -
specifications - Sectional specification for
class B single-mode fibres
IEC 61300-1 - Fibre optic interconnecting devices and EN 61300-1 -
passive components - Basic test and
measurement procedures - Part 1: General
and guidance
IEC 61300-2-1 - Fibre optic interconnecting devices and EN 61300-2-1 -
passive components - Basic test and
measurement procedures - Part 2–1: Tests
- Vibration (sinusoidal)
IEC 61300-2-4 - Fibre optic interconnecting devices and EN IEC 61300-2-4 -
passive components - Basic test and
measurement procedures - Part 2–4: Tests
- Fibre or cable retention
IEC 61300-2-9 - Fibre optic interconnecting devices and EN 61300-2-9 -
passive components - Basic test and
measurement procedures - Part 2–9: Tests
- Shock
IEC 61300-2-22 - Fibre optic interconnecting devices and - -
passive components - Basic test and
measurement procedures - Part 2–22:
Tests - Change of temperature
3
---------------------- Page: 5 ----------------------
SIST EN IEC 61753-101-03:2022
EN IEC 61753-101-03:2021 (E)
IEC 61300-2-33 - Fibre optic interconnecting devices and EN 61300-2-33 -
passive components - Basic test and
measurement procedures - Part 2–33:
Tests - Assembly and disassembly of fibre
optic mechanical splices, fibre
management systems and closures
IEC 61300-2-42 - Fibre optic interconnecting devices and EN 61300-2-42 -
passive components - Basic test and
measurement procedures - Part 2–42:
Tests - Static side load for strain relief
IEC 61300-2-46 - Fibre optic interconnecting devices and EN IEC 61300-2-46 -
passive components - Basic test and
measurement procedures - Part 2–46:
Tests - Damp heat, cyclic
IEC 61300-3-1 - Fibre optic interconnecting devices and EN 61300-3-1 -
passive components - Basic test and
measurement procedures - Part 3–1:
Examinations and measurements - Visual
examination
IEC 61300-3-3 - Fibre optic interconnecting devices and EN 61300-3-3 -
passive components - Basic test and
measurement procedures - Part 3–3:
Examinations and measurements - Active
monitoring of changes in attenuation and
return loss
IEC 61300-3-28 - Fibre optic interconnecting devices and EN 61300-3-28 -
passive components - Basic test and
measurement procedures - Part 3–28:
Examinations and measurements -
Transient loss
IEC 61753-1 - Fibre optic interconnecting devices and EN IEC 61753-1 -
passive components - Performance
standard - Part 1: General and guidance
IEC 61756-1 - Fibre optic interconnecting devices and EN IEC 61756-1 -
passive components - Interface standard
for fibre management systems - Part 1:
General and guidance
ISO 4892-3 - Plastics - Methods of exposure to EN ISO 4892-3 -
laboratory light sources - Part 3:
Fluorescent UV lamps
4
---------------------- Page: 6 ----------------------
SIST EN IEC 61753-101-03:2022
IEC 61753-101-03
®
Edition 1.0 2021-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components performance
standard –
Part 101-03: Fibre management systems for category OP – Outdoor protected
environment
Norme de performance pour les dispositifs d’interconnexion et composants
passifs fibroniques –
Partie 101-03: Systèmes de gestion de fibres pour la catégorie OP –
Environnement extérieur protégé
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.180.20 ISBN 978-2-8322-1029-2
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN IEC 61753-101-03:2022
– 2 – IEC 61753-101-03:2021 © IEC 2021
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Abbreviated terms . 8
5 General requirements . 8
5.1 General . 8
5.2 Storage, transportation and packaging . 9
5.3 Installation and intervention . 9
5.4 Marking and identification . 9
5.5 Materials . 9
5.6 Safety . 10
6 Test . 10
6.1 General . 10
6.2 Test sample preparation . 11
6.3 Test and measurement methods . 11
6.4 Sample size . 11
6.5 Pass/fail criteria . 11
6.6 Test report . 11
7 Performance requirements. 12
7.1 Pass/fail criteria . 12
7.2 Performance requirements . 13
Annex A (normative) Sample construction . 16
A.1 Fibre type for test sample . 16
A.2 FMS test sample configuration . 17
A.2.1 FMS test sample configuration with splices only . 17
A.2.2 FMS test sample with splices and connectors . 19
Annex B (normative) Installation test . 21
Annex C (informative) Access and reconfiguration tests . 22
Bibliography . 23
Figure A.1 – Sample configuration with splices only for climatic tests . 17
Figure A.2 – Sample configuration with splices only for mechanical tests . 18
Figure A.3 – Sample configuration with splices and connectors for climatic tests . 19
Figure A.4 – Sample configuration with splices and connectors for mechanical tests . 20
Figure B.1 – Test sample configuration for the installation test . 21
Table 1 – Pass/fail requirements . 12
Table 2 – Performance requirements . 13
Table A.1 – Fibre references for IEC 60793-2-50, subcategory B-652.D . 16
Table A.2 – Fibre references for IEC 60793-2-50, subcategory B-657.A1 . 16
Table A.3 – Fibre references for IEC 60793-2-50, subcategory B-657.A2 . 17
---------------------- Page: 8 ----------------------
SIST EN IEC 61753-101-03:2022
IEC 61753-101-03:2021 © IEC 2021 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING DEVICES AND
PASSIVE COMPONENTS PERFORMANCE STANDARD –
Part 101-03: Fibre management systems for category OP –
Outdoor protected environment
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 61753-101-03 has been prepared by subcommittee 86B: Fibre optic interconnecting
devices and passive components, of IEC technical committee 86: Fibre optics. It is an
International Standard.
This first edition cancels and replaces IEC 61753-101-3 the first edition published in 2006. This
edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) the terms and definitions have been updated according to IEC 61753-1:2018 and
IEC 61756-1:2019;
b) the test severities have been updated according to IEC 61753-1:2018;
c) detailed material tests for mould growth (IEC 60068-2-10) and UV light exposure (ISO 4892-
3) have been added;
---------------------- Page: 9 ----------------------
SIST EN IEC 61753-101-03:2022
– 4 – IEC 61753-101-03:2021 © IEC 2021
d) the detailed transport performance requirements have been removed;
e) IEC 60793-2-50 subcategory B-657 fibres for test samples in Annex A has been added.
The text of this International Standard is based on the following documents:
Draft Report on voting
86B/4497/FDIS 86B/4522/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/standardsdev/publications.
A list of all parts in the IEC 61753 series, published under the general title Fibre optic
interconnecting devices and passive components performance standard, can be found on the
IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 10 ----------------------
SIST EN IEC 61753-101-03:2022
IEC 61753-101-03:2021 © IEC 2021 – 5 –
FIBRE OPTIC INTERCONNECTING DEVICES AND
PASSIVE COMPONENTS PERFORMANCE STANDARD –
Part 101-03: Fibre management systems for category OP –
Outdoor protected environment
1 Scope
This part of IEC 61753 contains the minimum tests, test severities and measurement
requirements which a fibre management system need to meet in order to be categorised as
meeting the IEC standard, category OP – Outdoor Protected environment, as defined in
IEC 61753-1.
This performance standard for fibre management systems defines the requirements for
standard optical performance under a set of specified conditions. It contains a series or a set
of tests and measurements with clearly stated conditions, severities and pass/fail criteria. The
series of tests, commonly referred to as an operating service environment or performance
category, is intended to be a basis to prove the product’s ability to satisfy the requirements of
a specific application, market sector or user group.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60068-2-10, Environmental testing – Part 2-10: Tests – Test J and guidance: Mould growth
IEC 60721-3-1, Classification of environmental conditions – Part 3-1: Classification of groups
of environmental parameters and their severities – Storage
IEC 60721-3-2, Classification of environmental conditions – Part 3-2: Classification of groups
of environmental parameters and their severities – Transportation and handling
IEC 60793-2-50, Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre or cable retention
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature
---------------------- Page: 11 ----------------------
SIST EN IEC 61753-101-03:2022
– 6 – IEC 61753-101-03:2021 © IEC 2021
IEC 61300-2-33, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic
mechanical splices, fibre management systems and closures
IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-42: Tests – Static side load for strain relief
IEC 61300-2-46, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-46: Tests – Damp heat, cyclic
IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-1: Examinations and measurements – Visual examination
IEC 61300-3-3, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of
changes in attenuation and return loss
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-28: Examinations and measurements – Transient loss
IEC 61753-1, Fibre optic interconnecting devices and passive components – Performance
standard – Part 1: General and guidance
IEC 61756-1, Fibre optic interconnecting devices and passive components – Interface standard
for fibre management systems – Part 1: General and guidance
ISO 4892-3, Plastics – Methods of exposure to laboratory light sources – Part 3: Fluorescent
UV lamps
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
excursion loss
change in optical attenuation during the slow variations of environmental parameters
Note 1 to entry: Excursion loss is the ± deviation from the original value of the transmitted power at the start of the
test.
3.2
fibre management system
system to control, protect and store splices, connectors, passive optical components and fibres
from incoming to outgoing cables
Note 1 to entry: A fibre management system is intended for installation within a protective housing.
Note 2 to entry: A fibre management system is often called an "organiser".
[SOURCE: IEC 61756-1:2019, 3.1.2]
---------------------- Page: 12 ----------------------
SIST EN IEC 61753-101-03:2022
IEC 61753-101-03:2021 © IEC 2021 – 7 –
3.3
intervention
gain access to modify, add, remove or repair fibre circuits, splices, connectors or other
components between the incoming and outgoing cables of an existing fibre management system
3.4
installation
activities and handling operations to establish and install a protective housing including the
cables or by adding new circuits, splices, connectors and other components
3.5
installation conditions
circumstances that are fulfilled for an installation, including environmental conditions, size
interface between the protective housing and the fibre management system, optical
performance, additional/special conditions and safety requirements
3.6
multiple element
physical fibre separation level consisting of more than one single element
Note 1 to entry: This separation level has fibres from multiple cable elements on one splice tray and is also called
mass storage. It is the lowest (worst) degree of physical circuit separation.
[SOURCE: IEC 61756-1:2019, 3.1.3]
3.7
multiple ribbon
multiple element consisting of multiple optical fibres (circuits) arranged in ribbons (fibres in
parallel) which are also arranged (for example, in stacks)
[SOURCE: IEC 61756-1:2019, 3.1.5]
3.8
single circuit
physical fibre separation level where the optical circuit consists of one fibre (single fibre), or
more than one fibre, providing all services for one subscriber
Note 1 to entry: This fibre separation level has the fibre(s) of only one customer on one splice tray. It is the highest
(best) degree of physical circuit separation.
[SOURCE: IEC 61756-1:2019, 3.1.7]
3.9
single element
physical fibre separation level in the cable subassembly comprising one or more optical fibres
inside a common covering
Note 1 to entry: A single element provides services to more than one subscriber.
Note 2 to entry: This fibre separation level has all fibres from a cable element (e.g. loose tube) on one splice tray.
It is an intermediate degree of physical circuit separation (between single circuit and multiple element).
Note 3 to entry: Optical fibres in a common covering can be in a tube or inside one groove of a grooved cable
(slotted core cable).
[SOURCE: IEC 61756-1:2019, 3.1.9, modified – The end of the definition has been moved to a
new Note 3 to entry.]
---------------------- Page: 13 ----------------------
SIST EN IEC 61753-101-03:2022
– 8 – IEC 61753-101-03:2021 © IEC 2021
3.10
single ribbon
single element designed to carry all fibres of one ribbon
Note 1 to entry: Depending on the fibres deployment’, a single ribbon can contain all the fibres of one circuit (single
circuit) or the fibres of more than one circuit (single element).
[SOURCE: IEC 61756-1:2019, 3.1.11]
3.11
splice tray
structure that organises and controls storage of fibre splices in an orderly manner, together with
the associat
...