Resilient floor coverings - Specification for floor panels for loose laying

This European Standard specifies requirements and test methods for floor panels, which have surface layers consisting of resilient floor covering. The floor panels are considered suitable for domestic and commercial levels of use.
This European Standard is not applicable to floor panels that are subject to frequent wetting, such as bathrooms, laundry rooms and saunas.
This European Standard also specifies the requirements for marking and packaging.

Elastische Bodenbeläge - Spezifikation für Fußbodenpaneele für lose Verlegung

Diese Europäische Norm legt Anforderungen und Prüfverfahren an Fußbodenpaneele fest, deren Oberschichten
aus elastischen Bodenbelägen bestehen. Die Fußbodenpaneele werden für private und gewerbliche
Bereiche als geeignet angesehen.
Dieses Dokument gilt nicht für Bereiche, die einer häufigen Nässe ausgesetzt sind, wie z. B. Badezimmer,
Waschräume und Saunen.
Dieses Dokument legt auch die Anforderungen an Kennzeichnung und Verpackung fest.

Revêtements de sol résilients - Spécification des panneaux de plancher pour pose flottante

La présente Norme européenne spécifie les exigences et les méthodes d’essai relatives aux panneaux de
plancher dont les couches de surface sont constituées d’un revêtement de sol résilient. Ces panneaux de
plancher sont considérés comme étant appropriés à des niveaux d’utilisation domestique et commerciale.
La présente Norme européenne ne s’applique pas aux panneaux de plancher soumis fréquemment à des
conditions de forte humidité, comme les salles de bain, les buanderies et les saunas.
La présente norme européenne comprend également les exigences relatives au marquage et à l’emballage.

Netekstilne talne obloge - Specifikacija talnih plošč za prosto položeno inštalacijo

Ta evropski standard določa zahteve in preskusne metode za talne plošče, katerih vrhnje plasti so sestavljene iz odpornih talnih oblog. Talne plošče veljajo za primerne za domačo in gospodarsko stopnjo uporabe.
Ta evropski standard ne velja za talne plošče, ki so izpostavljene pogostemu močenju, kot so kopalnice, pralnice in savne.
Ta evropski standard prav tako določa zahteve za označevanje in pakiranje.

General Information

Status
Withdrawn
Publication Date
03-Oct-2011
Withdrawal Date
23-Oct-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
24-Oct-2018
Due Date
16-Nov-2018
Completion Date
24-Oct-2018

Relations

Buy Standard

Standard
EN 14085:2011
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Elastische Bodenbeläge - Spezifikation für Fußbodenpaneele für lose VerlegungRevêtements de sol résilients - Spécification des panneaux de plancher pour pose flottanteResilient floor coverings - Specification for floor panels for loose laying97.150Netekstilne talne oblogeNon-textile floor coveringsICS:Ta slovenski standard je istoveten z:EN 14085:2010SIST EN 14085:2011en,fr,de01-november-2011SIST EN 14085:2011SLOVENSKI
STANDARDSIST EN 14085:20031DGRPHãþD



SIST EN 14085:2011



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14085
April 2010 ICS 97.150 Supersedes EN 14085:2003English Version
Resilient floor coverings -Specification for floor panels for loose laying
Revêtements de sol résilients - Spécification des panneaux de plancher pour pose flottante
Elastische Bodenbeläge - Spezifikation für Fußbodenpaneele für lose Verlegung This European Standard was approved by CEN on 27 February 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14085:2010: ESIST EN 14085:2011



EN 14085:2010 (E) 2 Contents Page Foreword .31 Scope .42 Normative references .43 Terms and definitions .54 Requirements .54.1 General requirements for the floor panels .54.2 Resilient floor coverings .74.3 General requirements for the surface layer .74.3.1 General .74.3.2 Residual indentation .74.3.3 Colour fastness to artificial light .74.3.4 Hardness of rubber surface .74.4 Classification requirements .74.4.1 General .74.4.2 Classification requirements for the surface layer .95 Marking and packaging .95.1 Marking .95.2 Packaging . 10Annex A (normative)
Determination of flatness . 11A.1 Sampling . 11A.2 Conditioning . 11A.3 Apparatus . 11A.3.1 Dial gauge . 11A.3.2 Rigid surface . 11A.3.3 Thickness gauge . 11A.4 Procedure . 12A.4.1 Determination of width flatness (fw) . 12A.4.2 Determination of length flatness (fl). 13A.5 Recording and expression of results . 14A.5.1 General . 14Annex B (normative)
Determination of openings and height differences between floor panels . 15B.1 Sampling . 15B.2 Conditioning . 15B.3 Apparatus . 15B.3.1 Thickness gauges . 15B.3.2 Calliper gauge . 15B.3.3 Test surface . 15B.4 Procedure . 15B.4.1 Assembly . 15B.4.2 Determination of openings between panels . 16B.4.3 Determination of height difference . 16B.5 Calculation and expression of results . 16Annex C (normative)
Determination of dimensional variations caused by changes in humidity . 17C.1 General . 17C.2 Sampling . 17C.3 Conditioning . 17C.4 Procedure . 18C.5 Calculation and expression of results . 18Annex D (normative)
Test report for tests carried out in accordance with Annexes A, B and C . 19Annex E (informative)
Optional properties . 20Bibliography . 21 SIST EN 14085:2011



EN 14085:2010 (E) 3 Foreword This document (EN 14085:2010) has been prepared by Technical Committee CEN/TC 134 “Resilient, textile and laminate floor coverings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2010, and conflicting national standards shall be withdrawn at the latest by October 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14085:2003. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 14085:2011



EN 14085:2010 (E) 4
1 Scope This European Standard specifies requirements and test methods for floor panels, which have surface layers consisting of resilient floor covering. The floor panels are considered suitable for domestic and commercial levels of use. This European Standard is not applicable to floor panels that are subject to frequent wetting, such as bathrooms, laundry rooms and saunas. This European Standard also specifies the requirements for marking and packaging. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references only the edition cited applies. For undated references the latest edition of the referenced document (including any amendments) applies. EN 309:2005, Particleboards – Definition and classification EN 316:2009, Wood fibre boards – Definition, classification and symbols EN 424, Resilient floor coverings – Determination of the effect of simulated movement of a furniture leg EN 425, Resilient and laminate floor coverings – Castor chair test EN 427, Resilient floor coverings – Determination of the side length, squareness and straightness of tiles EN 428, Resilient floor coverings – Determination of overall thickness EN 548, Resilient floor coverings – Specification for plain and decorative linoleum EN 649, Resilient floor coverings – Homogeneous and heterogeneous polyvinyl chloride floor coverings – Specification EN 651, Resilient floor coverings — Polyvinyl chloride floor coverings with foam layer – Specification EN 652, Resilient floor coverings – Polyvinyl chloride floor coverings with cork-based backing – Specification EN 653, Resilient floor coverings – Expanded (cushioned) polyvinyl chloride floor coverings – Specification EN 655, Resilient floor coverings – Tiles of agglomerated composition cork with polyvinyl chloride wear layer – Specification EN 669:1997, Resilient floor coverings – Determination of dimensional stability of linoleum tiles caused by changes in atmospheric humidity EN 685, Resilient, textile and laminate floor coverings - Classification EN 1817, Resilient floor coverings – Specification for homogeneous and heterogeneous smooth rubber floor coverings EN 12104, Resilient floor coverings – Cork floor tiles – Specification EN 12199, Resilient floor coverings – Specifications for homogeneous and heterogeneous relief rubber floor coverings SIST EN 14085:2011



EN 14085:2010 (E) 5 EN 12466:1998, Resilient floor coverings – Vocabulary EN 13845, Resilient floor coverings – Polyvinyl chloride floor coverings with particle based enhanced slip resistance – Specification EN 14565, Resilient floor coverings – Floor coverings based upon synthetic thermoplastic polymers – Specification ISO 24336, Laminate floor coverings – Determination of thickness swelling after partial immersion in water 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 309:2005, EN 316:2009, EN 12466:1998 and the following apply. 3.1
floor panel product generally of rectangular form consisting of a compact layer of a substrate and a surface layer of a resilient floor covering 3.2
substrate core material of the floor panel, which is tongued and grooved or otherwise constructed to allow the panels to be assembled together using an appropriate glue or by other assembling techniques. NOTE 1 The substrate might include a backing. NOTE 2 The substrate is generally a particleboard, as defined in EN 309, or a Medium Density Fibreboard or High Density Fibreboard (MDF or HDF) as defined in EN 316. 3.3 surface layer upper decorative layer of one of the specified resilient floor coverings, which is bonded to the substrate directly or as total product and is intended to be the visible side when the floor is installed.
4 Requirements 4.1 General requirements for the floor panels All classes of floor panels including the surface layer shall conform to the requirements specified in Table 1 when tested in accordance with the test methods specified in Table 1. SIST EN 14085:2011



EN 14
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.