Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore assembly, screened (braided) and jacketed - Operating temperatures between - 65 °C and 260 °C - Part 001: Technical specification

This document specifies the required characteristics and test procedures for fire resistant or fire proof electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of 600 VAC, a frequency of maximum 2 000 Hz and a long-term temperature of up to 260 °C (ambient temperature plus temperatures rise in conductor).
These cables shall also maintain a specific dielectric strength when they are subjected to a flame of 1 100 °C after five minutes (fire resistant) or 15 minutes (fire proof) exposure.

Luft- und Raumfahrt - Feuerberständige elektrische Leitungen - Einzel- und mehradrig verdrillte Leitungen, geschirmt (Geflecht) und ummantelt - Betriebstemperaturen zwischen - 65 °C und 260 °C - Teil 001: Technische Lieferbedingungen

Dieses Dokument legt die Anforderungen an und Prüfverfahren für feuerbeständige oder feuerfeste elektri¬sche Leitungen zur Verwendung in elektrischen Bordnetzen fest. Sie sind bei einer Nennwechselspannung von 600 VAC, einer Frequenz von höchstens 2 000 Hz sowie einer Langzeittemperatur von bis zu 260 °C (Umgebungstemperatur zuzüglich Temperaturanstieg im Leiter) zu betreiben.
Diese Leitungen müssen außerdem eine bestimmte Spannungsfestigkeit beibehalten, wenn sie 5 min (feuer¬beständig) oder 15 min (feuerfest) einer Flamme von 1 100 °C ausgesetzt sind.

Série aérospatiale - Câbles électriques blindés résistant au feu - Simple et multifilaire blindé (tresse) gainé - Températures de fonctionnement comprises entre - 65 °C et 260 °C - Partie 001 : Spécification technique

Aeronavtika - Električni, ognjevzdržni kabli - Enožilni in večžilni prepleteni kabli, oklopljeni (opleteni) in oplaščeni - Delovne temperature med -65 °C in 260 °C - 001. del: Tehnična specifikacija

General Information

Status
Withdrawn
Publication Date
14-May-2009
Withdrawal Date
01-Jul-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
02-Jul-2019
Due Date
25-Jul-2019
Completion Date
02-Jul-2019

Relations

Buy Standard

Standard
EN 4608-001:2009
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 4608-001:2009
01-julij-2009
$HURQDYWLND(OHNWULþQLRJQMHY]GUåQLNDEOL(QRåLOQLLQYHþåLOQLSUHSOHWHQLNDEOL
RNORSOMHQL RSOHWHQL LQRSODãþHQL'HORYQHWHPSHUDWXUHPHGƒ&LQƒ&
GHO7HKQLþQDVSHFLILNDFLMD
Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore
assembly, screened (braided) and jacketed - Operating temperatures between - 65 °C
and 260 °C - Part 001: Technical specification
Luft- und Raumfahrt - Feuerberständige elektrische Leitungen - Einzel- und mehradrig
verdrillte Leitungen, geschirmt (Geflecht) und ummantelt - Betriebstemperaturen
zwischen - 65 °C und 260 °C - Teil 001: Technische Lieferbedingungen
Série aérospatiale - Câbles électriques blindés résistant au feu - Simple et multifilaire
blindé (tresse) gainé - Températures de fonctionnement comprises entre - 65 °C et 260 °
C - Partie 001 : Spécification technique
Ta slovenski standard je istoveten z: EN 4608-001:2006
ICS:
13.220.99 Drugi standardi v zvezi z Other standards related to
varstvom pred požarom protection against fire
49.060 /HWDOVNDLQYHVROMVND Aerospace electric
HOHNWULþQDRSUHPDLQVLVWHPL equipment and systems
SIST EN 4608-001:2009 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 4608-001:2009

---------------------- Page: 2 ----------------------

SIST EN 4608-001:2009


EUROPEAN STANDARD EN 4608-001

NORME EUROPÉENNE

EUROPÄISCHE NORM June 2006
ICS 49.060
English Version
Aerospace series - Cable, electrical, fire resistant - Single and
twisted multicore assembly, screened (braided) and jacketed -
Operating temperatures between - 65 °C and 260 °C - Part 001:
Technical specification
Série aérospatiale - Câbles électriques blindés résistant au Luft- und Raumfahrt - Feuerberständige elecktrische
feu - Simple et multifilaire blindé (tresse) gainé -
Leitungen - Einzel- und mehradrig verdrillte Leitungen,
Températures de fonctionnement comprises entre - 65 °C geschirmt (Geflecht) und ummantelt - Betriebstemperaturen
et 260 °C - Partie 001 : Spécification technique zwischen - 65 °C und 260 °C - Teil 001: Technische
Lieferbedingungen
This European Standard was approved by CEN on 20 April 2006.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.

CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.






EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2006 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4608-001:2006: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 4608-001:2009
EN 4608-001:2006 (E)
Contents Page
Foreword.3
1 Scope .4
2 Normative references .4
3 Terms and definitions .4
4 Materials and construction of cables .5
5 Required characteristics.5
6 Tests methods.6
7 Qualification and acceptance conditions.10
8 Identification, marking . 12
9 Packaging, labelling and delivery length . 12

2

---------------------- Page: 4 ----------------------

SIST EN 4608-001:2009
EN 4608-001:2006 (E)
Foreword
This European Standard (EN 4608-001:2006) has been prepared by the European Association of Aerospace
Manufacturers - Standardization (AECMA-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of
AECMA, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by December 2006, and conflicting national standards shall be withdrawn
at the latest by December 2006.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
Switzerland and the United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 4608-001:2009
EN 4608-001:2006 (E)
1 Scope
This document specifies the required characteristics and test procedures for fire resistant or fire proof
electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of
600 VAC, a frequency of maximum 2 000 Hz and a long-term temperature of up to 260 °C (ambient
temperature plus temperatures rise in conductor).
These cables shall also maintain a specific dielectric strength when they are subjected to a flame of 1 100 °C
after five minutes (fire resistant) or 15 minutes (fire proof) exposure.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
These references are not fully applicable. The present specification defines the field of application of each
document.
ISO 2574, Aircraft — Electrical cables — Identification marking.
EN 2234, Aerospace series — Cable, electrical, fire resistant — Technical specification.
EN 2235, Aerospace series — Single and multicore electrical cables, screened and jacketed — Technical
specification.
*
EN 3475-100 , Aerospace series — Cables, electrical, aircraft use — Test methods — Part 100: General.
1)
EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables.
EN 4608-002, Aerospace series — Cable, electrical, fire resistant — Single and twisted multicore assembly,
screened (braided) and jacketed — Operating temperatures between − 65 °C and 260 °C — Part 002:

General.
EN 4608-005, Aerospace series — Cable, electrical, fire resistant — Single and twisted multicore assembly,
screened (braided) and jacketed — Operating temperatures between − 65 °C and 260 °C — Part 005: DW
1)
family — lightweight two-core gauge 24 for data transmission — UV laser printable — Product standard.
EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace
standard parts.
3 Terms and definitions
For the purposes of this European Standard, the terms and definitions given in EN 3475-100 apply.

*
And all parts quoted in Table 1.
1) Published as AECMA Prestandard at the date of publication of this standard.
4

---------------------- Page: 6 ----------------------

SIST EN 4608-001:2009
EN 4608-001:2006 (E)
4 Materials and construction of cables
4.1 General
4.1.1 Materials
The material shall conform to the applicable product standard.
The materials used shall have no corrosive effect upon the conductors and screens and shall not be
susceptible to attack by mould and other microorganisms.
4.1.2 Individual cores
The individual cores shall conform to EN 2234 and applicable product standard.
4.1.3 Construction
The construction shall conform to EN 2234.
4.2 Construction of cables
4.2.1 Assembly
The lay length of the outer layer shall not be less than 8 times and not more than 16 times the nominal
diameter of the cabled cores. The cores shall not be spliced.
4.2.2 Screened cables
Shielding shall conform to EN 2235.
Efficiency of shielding is not required during the flame exposure.
4.3 Colour
The colour of the outer layer and stripes shall be in accordance with EN 4608-002.
5 Required characteristics
The required characteristics for cables tested according to 6.1 shall conform to the values specified in the
product standard or in this specification
5

------------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.