SIST EN 14420-6:2013
(Main)Hose fittings with clamp units - Part 6: TW tank truck couplings
Hose fittings with clamp units - Part 6: TW tank truck couplings
This European Standard specifies the fitting combinations, design, materials and dimensions for hose fittings with couplings for tank trucks (TW couplings). Couplings for tank trucks in accordance with this document are intended to link hoses with connections for the transport of liquids, solid matters and gases with the exception of liquid gas and steam. They can be employed in a working pressure range of -0,8 bar1) up to 16 bar at working temperatures of -20 °C up to +65 °C. Couplings for tank trucks for other operating conditions are subject to agreement.
Schlaucharmaturen mit Klemmfassungen - Teil 6: TW Tankwagen-Kupplungen
Diese Europäische Norm legt die Konstruktion, Werkstoffe und Maße für Schlaucharmaturen mit Kupplungen für Tankwagen (TW-Kupplungen) fest.
Kupplungen für Tankwagen nach dieser Norm dienen der Verbindung von Schläuchen mit Anschlüssen zum Fördern von Flüssigkeiten, Feststoffen und Gasen, ausgenommen Flüssiggas und Dampf. Die Kupplungen können in einem Arbeitsdruckbereich von –0,8 bar bis 16 bar bei Arbeitstemperaturen von –20 °C bis 65 °C verwendet werden. Tankwagen-Kupplungen für andere Betriebsbedingungen nach Vereinbarung.
WARNUNG — Vater- und Mutterteil-Blindkupplungen sind druckbeständige Verschlüsse. Sie über-nehmen jedoch nicht die Funktion eines Absperrorgans, das in jedem Fall vorgeschaltet sein sollte, solange Leitungen unter Druck stehen.
Raccords pour flexibles avec demi-coquille - Partie 6: Raccords TW pour camion-citerne
La présente norme européenne spécifie les prescriptions applicables à la conception, aux matériaux et aux dimensions des raccords pour flexibles avec raccordements pour camions citernes (raccords TW).
Les raccordements pour camions citernes conformes au présent document sont destinés à relier les tuyaux munis de raccordements pour le transport de liquides, de matières solides et de gaz, à l'exception des gaz liquéfiés et de la vapeur. Ils sont utilisables dans une plage de pression de service de 0,8 bar à 16 bar pour des températures de service de 20 °C à 65 °C. Les raccordements pour camions citernes utilisés dans d'autres conditions de service font l'objet d'un accord.
AVERTISSEMENT : Les raccordements anti-poussière mâles et femelles sont des capuchons résistant à la pression. Ils ne fonctionnent pas comme un dispositif de verrouillage de sorte que, si les canalisations restent sous pression, il faut les compléter par un dispositif d'arrêt.
Cevni fitingi z objemkami - 6. del: Spojke za TW cisterne
Ta evropski standard določa kombinacije, načrtovanje, materiale in dimenzije fitingov za cevne fitinge s spojkami za TW cisterne. V skladu s tem dokumentom so spojke za TW cisterne namenjene povezovanju cevi s priključki za prevoz tekočin, trdnih snovi in plinov, razen tekočega plina in pare. Uporabljajo se lahko pri delovnem tlaku od -0,8 bara1) do 16 barov pri delovni temperaturi od -20 °C do +65 °C. Glede spojk za TW cisterne za delovanje pod drugačnimi obratovalnimi razmerami se je treba dogovoriti.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Cevni fitingi z objemkami - 6. del: Spojke za TW cisterneSchlaucharmaturen mit Klemmfassungen - Teil 6: TW Tankwagen-KupplungenRaccords pour flexibles avec demi-coquille - Partie 6: Raccords TW pour camion-citerneHose fittings with clamp units - Part 6: TW tank truck couplings23.040.60Prirobnice, oglavki in spojni elementiFlanges, couplings and jointsICS:Ta slovenski standard je istoveten z:EN 14420-6:2013SIST EN 14420-6:2013en,fr,de01-september-2013SIST EN 14420-6:2013SLOVENSKI
STANDARDSIST EN 14420-6:2005+A1:20071DGRPHãþD
SIST EN 14420-6:2013
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14420-6
July 2013 ICS 23.040.70 Supersedes EN 14420-6:2004+A1:2007English Version
Hose fittings with clamp units - Part 6: TW tank truck couplings Raccords pour flexibles avec demi-coquille - Partie 6: Raccords TW pour camion-citerne
Schlaucharmaturen mit Klemmfassungen - Teil 6: TW Tankwagen-Kupplungen This European Standard was approved by CEN on 15 May 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14420-6:2013: ESIST EN 14420-6:2013
EN 14420-6:2013 (E) 2 Contents Page Foreword .3 1 Scope .5 2 Normative references .5 3 Terms and definitions .6 4 Fitting combinations .6 5 Dimensions, designations .6 5.1 Hose fittings with TW couplings .6 5.2 Male coupling (type VK) . 10 5.3 Female coupling (type MK) . 15 5.4 Dust cap (type MB) . 23 5.5 Dust plug (type VB). 27 6 Materials . 31 6.1 General . 31 6.2 Hose tail types MKST and VKST . 31 6.3 Protecting rings of hose tail type MKST and VKST . 31 6.4 Thread gasket of male coupling type VK . 32 6.5 Fastening component of female coupling type MK . 32 6.6 Main gasket of female coupling type MK . 32 7 Design . 32 8 Fitting of hose couplings . 33 9 Marking . 33 10 Type testing and quality control . 33 Annex A (normative)
Gauges for TW tank truck couplings . 34 A.1 General . 34 A.2 Design; designation, dimensions and materials . 34 A.3 Marking . 49 Bibliography . 50
SIST EN 14420-6:2013
EN 14420-6:2013 (E) 3 Foreword This document (EN 14420-6:2013) has been prepared by Technical Committee CEN/TC 218 “Rubber and plastics hoses and hose assemblies”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2014, and conflicting national standards shall be withdrawn at the latest by January 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14420-6:2004+A1:2007. In comparison to EN 14420-6:2004+A1:2007, the following changes have been made: In Clause 1, the warning paragraph has been revised. In Clause 2, the normative references have been updated. A new Clause 3 "Terms and definitions" has been added. The term "sealing ring" has been replaced by "gasket" (main gasket/thread gasket). Clause 4 "Survey" has been renamed "Fitting combinations". In 5.2.2.3, the body designation of a male coupling (DN 100) has been changed. In 5.4.2.3, the designation of a dust cap has been changed. In 5.5.2.3, the designation of a dust plug has been changed. The requirements on thread gasket materials in 6.4 and main gasket materials in 6.6 have been revised. In Clause 9, the requirements for marking have been reviewed. Content of Clause 10 "Type testing and quality control" has been replaced by a reference to EN 14420-1. The standard has been revised editorially. EN 14420, Hose fittings with clamp units consists of the following parts: Part 1: Requirements, types of fixing and connection, designation and testing Part 2: Hose side parts of hose tail Part 3: Clamp units, bolted or pinned Part 4: Flange connections Part 5: Threaded connections SIST EN 14420-6:2013
EN 14420-6:2013 (E) 4 Part 6: TW tank truck couplings Part 7: Cam locking couplings Part 8: Symmetrical half couplings (Guillemin system) According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 14420-6:2013
EN 14420-6:2013 (E) 5 1 Scope This European Standard specifies the fitting combinations, design, materials and dimensions for hose fittings with couplings for tank trucks (TW couplings). Couplings for tank trucks in accordance with this document are intended to link hoses with connections for the transport of liquids, solid matters and gases with the exception of liquid gas and steam. They can be employed in a working pressure range of –0,8 bar1) up to 16 bar at working temperatures of –20 °C up to +65 °C. Couplings for tank trucks for other operating conditions are subject to agreement. WARNING — Male and female dust couplings are pressure resistant plugs. They do not fulfil the function of a locking device, which should be installed in any case as long as the hose assembly is under pressure. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 586-2, Aluminium and aluminium alloys — Forgings — Part 2: Mechanical properties and additional property requirements EN 10083-2, Steels for quenching and tempering — Part 2: Technical delivery conditions for non alloy steels EN 10088-1, Stainless steels — Part 1: List of stainless steels EN 10213, Steel castings for pressure purposes EN 12420, Copper and copper alloy — Forgings EN 14420-1:2013, Hose fittings with clamp units — Part 1: Requirements, types of fixing and connection, designation and testing EN 14420-2, Hose fittings with clamp units — Part 2: Hose side parts of hose tail EN 14420-3, Hose fittings with clamp units — Part 3: Clamp units, bolted or pinned EN 14420-5: 2013, Hose fittings with clamp units — Part 5: Threaded connections EN 22768-1, General tolerances — Part 1: Tolerances for linear and angular dimensions without individual tolerance indications (ISO 2768-1) EN 22768-2, General tolerances — Part 2: Geometrical tolerances for features without individual tolerance indications (ISO 2768-2) EN ISO 4042, Fasteners — Electroplated coatings (ISO 4042) EN ISO 8330:2008, Rubber and plastics hoses and hose assemblies — Vocabulary (ISO 8330:2007)
1) 1 bar = 0,1 MPa. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 6 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 8330:2008 and the following apply. 3.1 DN (nominal size) alpha-numeric designation of size for components of a pipework system, which is used for reference purposes. It comprises the letters DN followed by a dimensionless whole number which is indirectly related to the physical size, in millimetres, of the bore or outside diameter of the end connections. Note 1 to entry: The number following the letters DN does not represent a measurable value and should not be used for calculation purposes except where specified in the relevant standard. Note 2 to entry: In those standards which use the DN designation system, any relationship between DN and component dimensions should be given, e.g. DN/OD or DN/ID. [SOURCE: EN ISO 6708:1995, 2.1] 3.2 main gasket interface gasket between the male and female part of a coupling 3.3 thread gasket flat faced gasket for threads according to EN ISO 228-1 3.4 protection ring ring which protects the valve from hitting the ground or draggling on the ground
4 Fitting combinations Hose fittings with TW coupling: Female coupling (Type MKS) and male coupling (Type VKS).
Usual fitting combination for the filling of the storage tank: Female coupling (Type MK) and male coupling (Type VK). Usual fitting combination for closing off the outlet end of the TW: Female coupling (Type MK) and male dust coupling (Type VB). Usual fitting combination for closing off the filling nozzle or the storage tank: Female dust coupling (Type MB) and male coupling (Type VK). 5 Dimensions, designations 5.1 Hose fittings with TW couplings 5.1.1 General A hose fitting with TW coupling for female coupling (type MKS) is shown in Figure 1. A hose fitting with TW coupling for male coupling (type VKS) is shown in Figure 2. A parts list for Figure 1 and Figure 2 is given in Table 1. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 7 Dimensions in millimetres
Figure 1 — Hose fitting with TW coupling for female coupling (type MKS) Figure 2 — Hose fitting with TW coupling for male coupling (type VKS) Table 1 — Parts list Item No. Designation Requirements 1
Tension ring with levers
according to 5.3.4.2 and 5.3.4.3 2
Main gasket
according to 5.3.4.4 3
Hose tail type MKST
according to 5.1.2 4
Clamp unit
according to EN 14420-3 5
Hose tail type VKST
according to 5.1.3 6
Protecting ring
according to 5.1.4 Designation of a complete hose fitting shall be according to EN 14420-1. 5.1.2 Hose tail with female TW coupling Dimensions for a hose tail with female TW coupling (type MKST) are shown in Figure 3; values are given in Table 2. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 8 Type MKST
Key a Coupling side part of the tail; other dimensions and specifications according to 5.3. b Hose side part of the tail; dimensions according to EN 14420-2. Figure 3 — Hose tail type MKST Table 2 — Hose tail type MKST Dimensions in millimetres Nominal size
DN For hose internal
diameter l1 l2 l3 Connection female TW coupling Hose connection min. max. 10+ 50 40 38 68 24 26 50 50 75 — 80 65 63
98 27 35 80 75 102 35 100 100 100 125 27 35,5
Example for an ordering designation of a complete hose tail with female TW coupling (type MKST) with nominal size DN 50 on coupling connection side and nominal size DN 40 on hose connecting side, made of copper-zinc alloy (CW614N): Hose tail EN 14420-6 — MKST — 50 — 40 — CW614N 5.1.3 Hose tail with male TW coupling Dimensions for a hose tail with male TW coupling (type VKST) are shown in Figure 4; values are given in Table 3. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 9 Type VKST
Key a Coupling side part of the tail; other dimensions and specifications according to 5.2. b Hose side part of the tail; dimensions shall be according to EN 14420-2. Figure 4 — Hose tail type VKST Table 3 — Hose tail type VKST Dimensions in millimetres Nominal size
DN For hose internal diameter d1 l4 l5 l6 l7 Connection male TW coupling Hose connection
Tolerances min. ± 0,5 min. max. 50 40 38 45 03,0− 80 37,5 2,5 32 50 50 58 87 3 30 80 65 63 75 110,5 48 4 40 80 75 90 8,03,0+− 115 100 100 100 113 13,0+− 134,5 44,5 4 35
Example for an ordering designation of a complete hose tail with male TW coupling (type VKST) with nominal size DN 80 on coupling connection side and nominal size DN 80 on hose connection side, made of stainless steel (1.4571): Hose tail EN 14420-6 — VKST — 80 — 80 — 1.4571 5.1.4 Protecting ring The protecting ring is intended to prevent the external surface of the male couplings from damage, which may be result of hose pipeline handling, e.g. by falling down to earth. The protecting ring does not have to conform to Figure 5; only fixed dimensions in Table 4 shall be used. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 10
Figure 5 — Protecting ring Table 4 — Protecting rings Dimensions in millimetres Nominal size
DN b d2 d3 Connection male TW coupling Hose connection ± 0,3 5,00+ ± 0,5 50 40 4,5 45,5 90 50 58,5 80 65 6 75,5 122 80 91 100 100 7 114,5 153
Example for an ordering designation of a protecting ring for a hose tail with nominal size DN 50 of the male coupling connection side and nominal size DN 40 on the hose connection side, made of polyamide (PA): Protecting ring EN 14420-6 — 50 — 40 — PA
5.2 Male coupling (type VK) 5.2.1 General A male coupling (type VK) is shown in Figure 6. A parts list for Figure 6 is given in Table 5. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 11
Figure 6 — Male coupling (type VK) Table 5 — Parts list Pos. No. Number of pieces Designation 1 1 Body 8 1 Thread gasketa
a Dimensions according to EN 14420-5.
Example for an ordering designation of a complete male coupling (type VK) with nominal size DN 80 and maximum working pressure 16 bar, made of copper-zinc alloy (CW614N): Coupling EN 14420-6 — VK — 80 — 16 — CW614N For connection with hoses, hose tails according to EN 14420-5 can be screwed into the male coupling (type VK) or one-piece hose fittings in accordance with 5.1 can be used. 5.2.2 Components 5.2.2.1 Body DN 50 and DN 80 (item No. 1) Dimensions for bodies with nominal size DN 50 and DN 80 are shown in Figure 7; values are given in Table 6. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 12
Key a The spatial arrangement do not have to correspond to the drawing. b Marking c Straight knurled portion d Thread according to EN 14420-5 e The angle between cams (90°) shall be checked with a gauge according to Annex A. Figure 7 — Body DN 50 and DN 80 SIST EN 14420-6:2013
EN 14420-6:2013 (E) 13 Table 6 — Dimensions for body DN 50 and DN 80 Dimensions in millimetres Nominal size DN b1 d1 d3 d4 d5 d6 d7 d8 e1 e2 ± 0,2
± 0,5
Tolerances ± 0,4 ± 0,5
± 0,2 ± 0,6 0,50+ 50 6,5 48 67 55,5 4,00+ 60 77 8 60,5 7 2,5 80 8,5 76 100 84,5 ± 0,5 90 110 9 88,5 8 3,5
Nominal size
DN g1 g2
5,00+ h1
± 1 h2
05,0− h3
± 0,2 h4
± 0,5 h5 h6
± 1 h7
min. r Gradient of the curve element 50 4,5 8 39 20 23,5 14,5 3 5 30 3,25 13 80 5 13 48 24 30,5 20 4 5 41 4,25 14 For DN 50 and DN 80, h3 should be checked with a gauge according to Annex A.
SIST EN 14420-6:2013
EN 14420-6:2013 (E) 14 5.2.2.2 Body DN 100 Dimensions for bodies with nominal size DN 100 are shown in Figure 8. Dimensions in millimetres
Key a Marking b The spatial arrangement do not have to correspond to the drawing. c Thread according to EN 14420-5 d Gauge dimension under all three curved elements shall be checked with a gauge according to Annex A. e Gradient 14 mm Figure 8 — Body DN 100
SIST EN 14420-6:2013
EN 14420-6:2013 (E) 15 5.2.2.3 Body designation Example for an ordering designation of a body item No. 1 (type VK) with nominal size DN 80 for a maximum working pressure of 16 bar, made of copper-zinc alloy (CW614N): Body EN 14420-6 — VK — 80 —16 —CW614N Table 7 — General tolerances for body dimensions Dimensions in millimetres Range of nominal sizes (DN) 3 to 6 > 6 to 18 > 18 to 30 > 30 to 50 > 50 to 80 > 80 to 120 > 120 to 200 ± 0,2 ± 0,3 ± 0,4 ± 0,5 ± 0,65 ± 0,8 ± 0,9
5.3 Female coupling (type MK) 5.3.1 Female coupling (type MK) DN 50 and DN 80 A female coupling (type MK) is shown in Figure 9. A parts list for Figure 9 is given in Table 8.
Key For 2, 3, 4, 5, 8 and 9 see Table 8. Figure 9 — Female coupling (type MK) DN 50 and DN 80 NOTE For connection with hoses, hose tails according to EN 14420-5 can be screwed into the female coupling (type MK) or one-piece hose fittings in accordance with 5.1 can be used. SIST EN 14420-6:2013
EN 14420-6:2013 (E) 16 Table 8 — Parts list Item No. Number of pieces Designation 2 1
Gasket fixture 3 1
Tension ring 4 1
Lever 5 1
Main gasket 8 1
Thread gasketa 9 1
Fastening component a Dimensions according to EN 14420-5:2013, 5.5.
SIST EN 14420-6:2013
EN 14420-6:2013 (E) 17 5.3.2 Female coupling (type MK) DN 100 A female coupling (type MK) with nominal size DN 100 is shown in Figure 10. Dimensions in millimetres
Key a Gauge dimension shall be checked with a gauge according to Annex A. b Thread according to EN 14420-5 c Dimensions of lever and lever position are not fixed. The spatial arrangement does not have to correspond to the drawing.
d Gauge dimension at all three claws e Gradient 14 mm Figure 10 — Female coupling (type MK) DN 100 SIST EN 14420-6:2013
EN 14420-6:2013 (E) 18 5.3.3 Designation Example for an ordering designation of a complete female coupling (type MK) with nominal size DN 80, for a maximum working pressure of 16 bar, made of copper-zinc alloy (CW614N): Coupling EN 14420-6 — MK — 80 — 16 —CW614N 5.3.4 Components 5.3.4.1 Gasket fixture DN 50 and DN 80 (item No. 2) Dimensions for gasket fixtures for nominal size DN 50 and DN 80 are shown in Figure 11; values are given in Table 9.
Key a Straight knurled portion b Thread according to EN 14420-5 c Magnified Figure 11 — Gasket fixture SIST EN 14420-6:2013
EN 14420-6:2013 (E) 19 Table 9 — Dimensions of gasket fixturea Dimensions in millimetres Nominal size DN b1
± 0,2 d1 d3 05,0− d4 05,0− d5
± 0,2 d6
± 0,4 d7 d8
± 0,2 d9 03,0− h1 05,0− h2 50 7,5 46 65 69,7 62,5 61 59 60,5 48 20 40,5 80 9,5 74 95 101 93 91 88 88,5 76 24 52
Nominal size DN h3 h4 5,00+ h5
± 0,2 h6 h7 b
max. n1
± 0,2 n2
± 0,2 r1 r2 T
...
Questions, Comments and Discussion