Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz - 40 GHz)

This basic standard applies to radio base stations and fixed terminal stations for wireless telecommunication systems as defined in Clause 4, operating in the frequency range 110 MHz to 40 GHz. The objective of the standard is to specify, for such equipment, the method for assessment of compliance distances according to the basic restrictions (directly or indirectly via compliance with reference levels) related to human exposure to radio frequency electromagnetic fields.

Grundnorm für die Berechnung und Messung der elektromagnetischen Feldstärke und SAR in Bezug auf die Sicherheit von Personen in elektromagnetischen Feldern von Mobilfunk-Basisstationen und stationären Teilnehmergeräten von schnurlosen Telekommunikationsanlagen (110 MHz bis 40 GHz)

Norme de base pour le calcul et la mesure des champs électromagnétiques et SAR associés à l'exposition des personnes provenant des stations de base radio et des stations terminales fixes pour les systèmes de radiotélécommunications (110 MHz - 40 GHz)

Osnovni standard za izračunavanje in merjenje moči elektromagnetnega polja in SAR v povezavi z izpostavljenostjo ljudi sevanjem zaradi radijskih baznih postaj in fiksnih terminalskih postaj za brezžične telekomunikacijske sisteme (110 MHz - 40 GHz)

Ta osnovni standard velja za radijske bazne postaje in fiksne terminalske postaje za brezžične telekomunikacijske sisteme, kot je določeno v Klavzuli 4, ki delujejo v frekvenčnem razponu od 100 MHz do 40 GHz. Namen tega standarda je za takšno opremo določiti metodo za ocenjevanje dogovorjene razdalje v skladu z osnovnimi omejitvami (neposredno ali posredno s skladnostjo z referenčnimi stopnjami), povezanimi s človeško izpostavljenostjo elektromagnetnim poljem radijske frekvence.

General Information

Status
Withdrawn
Publication Date
11-Jul-2010
Withdrawal Date
18-Oct-2020
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
16-Oct-2020
Due Date
08-Nov-2020
Completion Date
19-Oct-2020

Relations

Buy Standard

Standard
EN 50383:2010 - BARVE
English language
79 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50383:2010
01-september-2010
1DGRPHãþD
SIST EN 50383:2003
2VQRYQLVWDQGDUG]DL]UDþXQDYDQMHLQPHUMHQMHPRþLHOHNWURPDJQHWQHJDSROMDLQ
6$5YSRYH]DYL]L]SRVWDYOMHQRVWMROMXGLVHYDQMHP]DUDGLUDGLMVNLKED]QLKSRVWDMLQ
ILNVQLKWHUPLQDOVNLKSRVWDM]DEUH]åLþQHWHOHNRPXQLNDFLMVNHVLVWHPH 0+]
*+]
Basic standard for the calculation and measurement of electromagnetic field strength
and SAR related to human exposure from radio base stations and fixed terminal stations
for wireless telecommunication systems (110 MHz - 40 GHz)
Grundnorm für die Berechnung und Messung der elektromagnetischen Feldstärke und
SAR in Bezug auf die Sicherheit von Personen in elektromagnetischen Feldern von
Mobilfunk-Basisstationen und stationären Teilnehmergeräten von schnurlosen
Telekommunikationsanlagen (110 MHz bis 40 GHz)
Norme de base pour le calcul et la mesure des champs électromagnétiques et SAR
associés à l'exposition des personnes provenant des stations de base radio et des
stations terminales fixes pour les systèmes de radiotélécommunications (110 MHz - 40
GHz)
Ta slovenski standard je istoveten z: EN 50383:2010
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.070.01 Mobilni servisi na splošno Mobile services in general
SIST EN 50383:2010 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50383:2010

---------------------- Page: 2 ----------------------

SIST EN 50383:2010

EUROPEAN STANDARD
EN 50383

NORME EUROPÉENNE
June 2010
EUROPÄISCHE NORM

ICS 17.220.20; 33.070.01 Supersedes EN 50383:2002


English version


Basic standard for the calculation and measurement of electromagnetic
field strength and SAR related to human exposure from radio base
stations and fixed terminal stations for wireless telecommunication
systems (110 MHz - 40 GHz)



Norme de base pour le calcul et la mesure Grundnorm für die Berechnung und
des champs électromagnétiques et SAR Messung der elektromagnetischen
associés à l'exposition des personnes Feldstärke und SAR in Bezug auf die
provenant des stations de base radio Sicherheit von Personen
et des stations terminales fixes pour in elektromagnetischen Feldern
les systèmes de radiotélécommunications von Mobilfunk-Basisstationen
(110 MHz - 40 GHz) und stationären Teilnehmergeräten
von schnurlosen
Telekommunikationsanlagen
(110 MHz bis 40 GHz)


This European Standard was approved by CENELEC on 2010-06-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50383:2010 E

---------------------- Page: 3 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 2 -
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 106X,
Electromagnetic fields in the human environment. It was submitted to the Unique Acceptance Procedure
as a draft amendment and approved by CENELEC as a new edition on 2010-06-01.
This European Standard supersedes EN 50383:2002.
The main changes compared to EN 50383:2002 are as follows (minor changes are not listed):
− the frequency range has been extended to cover 300 MHz to 6 GHz now, was 300 MHz to 3 GHz
before
− the references to EN 50361 have been updated with referring to EN 62209-2:2010 now and
paragraphs have been removed, that are covered by EN 62210-2
− the former Annex A "Boundaries between field regions" has been replaced by an Annex
"Considerations for using far-field method"
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
− latest date by which the EN has to be implemented

at national level by publication of an identical
national standard or by endorsement (dop) 2011-06-01
− latest date by which the national standards conflicting
(dow) 2013-06-01
with the EN have to be withdrawn
__________

---------------------- Page: 4 ----------------------

SIST EN 50383:2010
- 3 - EN 50383:2010
1 Scope
This basic standard applies to radio base stations and fixed terminal stations for wireless
telecommunication systems as defined in Clause 4, operating in the frequency range 110 MHz to
40 GHz.

The objective of the standard is to specify, for such equipment, the method for assessment of compliance
distances according to the basic restrictions (directly or indirectly via compliance with reference levels)
related to human exposure to radio frequency electromagnetic fields.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

EN 62209-2:2010, Human exposure to radio frequency fields from hand-held and body-mounted wireless
communication devices – Human models, instrumentation, and procedures – Part 2: Procedure to
determine the specific absorption rate (SAR) for mobile wireless communication devices used in close
proximity to the human body (frequency range of 30 MHz to 6 GHz

ISO/IEC 17025:1999, General requirements for the competence of testing and calibration laboratories

ISO/IEC Guide 98-3:2008, Uncertainty of measurement – Part 3: Guide to the expression of uncertainty in
measurement (GUM:1995)

Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public
to electromagnetic fields (0 Hz to 300 GHz) (Official Journal L 197 of 30 July 1999)

International Commission on Non-Ionizing Radiation Protection (1998), Guidelines for limiting exposure in
time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). Health Physics 74, 494-522.

---------------------- Page: 5 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 4 -
3 Physical quantities, units and constants
3.1.1 Quantities
The internationally accepted SI-units are used throughout the standard.
Quantity Symbol Unit Dimensions
2
Current density J ampere per square metre A/m

Electric field strength E volt per metre V/m
2
Electric flux density D coulomb per square metre C/m
Electric conductivity siemens per metre S/m
σ
Frequency f hertz Hz
Magnetic field strength H ampere per metre A/m
2
Magnetic flux density B tesla (Vs/m) T
3
Mass density ρ kilo per cubic metre kg/m
Permeability µ henry per metre H/m
Permittivity ε farad per metre F/m
Specific absorption rate SAR watt per kilogram W/kg
Wavelength λ metre m
Temperature T kelvin K

3.1.2 Constants
Physical constant Magnitude
8
Speed of light in a vacuum c 2,997 x 10 m/s
-12
Permittivity of free space ε 8,854 x 10 F/m
0
-7
Permeability of free space µ 4π x 10 H/m
0
Impedance of free space η 120π (approx. 377) Ω
0
4 Terms and definitions
4.1
antenna
device that serves as a transducer between a guided wave (e.g. coaxial cable) and a free space wave, or
vice versa

---------------------- Page: 6 ----------------------

SIST EN 50383:2010
- 5 - EN 50383:2010
4.2
average (temporal) absorbed power
P
avg
the time-averaged rate of energy transfer defined by:

t
2
_
1
=
P P(t)dt

avg

t t
2 1
t
   1    (1)

where t and t are the start and stop time of the exposure. The period t – t is the exposure duration time
1 2 2 1


4.3
averaging time
t
avg
the appropriate time over which exposure is averaged for purposes of determining compliance with the
limits

4.4
base station
BS
in this standard, the term “Base Station” (BS) covers radio base stations as well as fixed terminal stations
intended for use in wireless telecommunications networks

4.5
basic restriction
restrictions on exposure to time-varying electric, magnetic and electromagnetic fields that are based
directly on established health effects. In the frequency range from 110 MHz to 10 GHz, the physical
quantity used is the specific absorption rate. Between 10 GHz and 40 GHz, the physical quantity is the
power density

4.6
compliance boundary
volume outside which any point of investigation is deemed to be compliant. Outside the compliance
boundary, the exposure levels do not exceed the basic restrictions irrespective of the time of exposure

4.7
conductivity
σ
ratio of the conduction-current density in a medium to the electric field strength. Conductivity is expressed
in units of siemens per metre (S/m)

4.8
continuous exposure
exposure for a duration exceeding the averaging time

4.9
duty factor (duty cycle)
ratio of the pulse duration to the pulse period of a periodic pulse train. A duty factor of unity corresponds
to continuous-wave operation

4.10
electric field strength
E
the magnitude of a field vector at a point that represents the force (F) on a positive small charge (q)
divided by the charge:
F
   E =     (2)
q
Electric field strength is expressed in units of volt per metre (V/m)

---------------------- Page: 7 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 6 -
4.11
electric flux density
D
the magnitude of a field vector that is equal to the electric field strength (E) multiplied by the permittivity
(ε ):
   D = εE    (3)
2
Electric flux density is expressed in units of coulomb per square metre (C/m )

4.12
equipment under test
EUT
device (such as transmitter, base station or antenna as appropriate) that is the subject of the specific test
investigation being described

4.13
fixed terminal station
a fixed terminal station, usually associated with the user, comprises the hardware, including transceivers,
necessary to transmit and receive radio signals. Fixed terminal stations with integrated antennas, fixed
terminal stations with connectors for external antennas and fixed terminal stations intended for use with
external antennas not supplied by the same manufacturer are covered.

In this standard, the fixed terminal stations are covered by the term “base station”

4.14
intrinsic impedance (of free space η )
0
η
the ratio of the electric field strength to the magnetic field strength of a propagating electromagnetic wave.
The intrinsic impedance of a plane wave in free space is 120 π (approximately 377) ohm

4.15
isotropy
deviation of the measured value with regard to various angles of incidence of the measured signal. In this
document, it is defined for incidences covering a hemisphere centred at the tip of the probe, with an
equatorial plane normal to the probe and expanding outside the probe.

The axial isotropy is defined by the maximum deviation of the measured quantity when rotating the probe
along its main axis with the probe exposed to a reference wave with normal incidence with regard to the
axis of the probe. The hemispherical isotropy is defined by the maximum deviation of the measured
quantity when rotating the probe along its main axis with the probe exposed to a reference wave with
varying angles of incidences with regard to the axis of the probe in the half space in front of the probe

4.16
linearity
maximum deviation over the measurement range of the measured quantity from the closest linear
reference curve defined over a given interval

4.17
loss tangent
the loss tangent tan(δ) is the ratio of the imaginary part of the complex dielectric constant of a material to
its real part

4.18
magnetic flux density
B
the magnitude of a field vector that is equal to the magnetic field strength H multiplied by the permeability
(µ) of the medium:
B = µ H    (4)


Magnetic flux density is expressed in units of tesla (T)

---------------------- Page: 8 ----------------------

SIST EN 50383:2010
- 7 - EN 50383:2010
4.19
magnetic field strength
H
the magnitude of a field vector in a point that results in a force ( F) on a charge q moving with the
velocity v
:
F = q (v × µ H)    (5)


The magnetic field strength is expressed in units of ampere per metre (A/m)

4.20
multi-band
a multi-band equipment is operating in more than one frequency band, e.g. GSM 900 and GSM 1800

4.21
multi-mode
a multi-mode equipment is operating with various radio communication systems, e.g. GSM and DECT

4.22
permeability
µ
the magnetic permeability of a material is defined by the magnetic flux density B divided by the magnetic
field strength H:
B
µ =
     (6)
H

where
µ is the permeability of the medium expressed in Henry per metre (H/m)

4.23
permittivity
ε
the property of a dielectric material (e.g. biological tissue) defined by the electrical flux density D divided
by the electrical field strength E:
D
ε =
     (7)
E


The permittivity is expressed in units of farad per metre (F/m)

4.24
phantom
in this context, a phantom is a simplified representation or a model similar in appearance to the human
anatomy and composed of materials with electrical properties similar to the corresponding tissues

4.25
point of investigation
POI
the location in space at which the value of E-field, H-field, Power flux density or SAR is evaluated. This
location is defined in Cartesian, cylindrical or spherical co-ordinates relative to the reference point on the
EUT

4.26
power flux density
S
power per unit area normal to the direction of electromagnetic wave propagation

4.27
radio base station
a radio base station, usually associated with the network, comprises the hardware, including transceivers,
necessary to transmit and receive radio signals. Radio base stations with integrated antennas, radio base
stations with connectors for external antennas and radio base stations intended for use with external
antennas not supplied by the same manufacturer are covered.

---------------------- Page: 9 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 8 -
In this standard, the radio base stations are covered by the term “base station”

4.28
radio frequency
RF
for purposes of these safety considerations, the frequency range of interest is 110 MHz to 40 GHz

4.29
relative permittivity
ε
r
the ratio of the permittivity of a dielectric material to the permittivity of free space i.e.

ε
ε =   (8)
r
ε

0

4.30
root-mean-square
rms
value obtained by taking the square root of the average of the square of the value of the periodic function
taken throughout one period

4.31
root-sum-square
rss
the rss value or the Hermitian magnitude of a vector v is obtained by the square root of the sum of the
squared rms values of all three orthogonal components of vector v. The rss value is proportional to the
joule heating and can be quite different from the rms amplitude of vector v

4.32
scanning system
the scanning system is the positioning system capable of placing the measurement probe at the specified
positions

4.33
specific absorption rate
SAR
the time derivative of the incremental energy (dW) absorbed by (dissipated in) an incremental mass (dm)
contained in a volume element (dV) of given mass density (ρ )



d dW d dW


 
SAR = = (9)
 
dt dm dt ρdV


SAR is expressed in units of watt per kilogram (W/kg)

---------------------- Page: 10 ----------------------

SIST EN 50383:2010
- 9 - EN 50383:2010
NOTE SAR can be calculated by:

2
σ E
i
SAR =
      (10)
ρ

d T
1)
  SAR = c     (11)
i
dt
(time = 0)


where

E rms value of the electric field strength in the tissue in V/m
i
σ conductivity of body tissue in S/m
3
ρ density of body tissue in kg/m
c heat capacity of body tissue in J/kg K
i
dT
time derivative of temperature in body tissue in K/s
dt


4.34
transmitter
device to generate radio frequency power for the purpose of communication but on its own is not intended
to radiate it


5 Applicability of compliance assessment methods
5.1.1 Introduction
Guidelines and recommended limits on human exposure to radio waves give basic restrictions in terms of
SAR or power flux density and also reference levels in terms of field strengths in the absence of the body.

The compliance boundary defines the volume outside which the exposure levels do not exceed the basic
restrictions irrespective of the time of exposure for the specific operating conditions of the EUT. The
compliance boundary is determined via a procedure where sufficient points of investigation are assessed.

It is technically possible to determine the compliance boundary through measurements or calculations of
SAR or electromagnetic fields relating to basic restrictions or reference levels, since compliance to the
reference levels guarantees compliance to the basic restrictions. However, the choice of the most
appropriate assessment method depends on a variety of other considerations.

Where the assessment is made through SAR, it should be noted that both localised and whole-body basic
restrictions must be considered. Spatial averaging may be used with field strength assessments in order
to assess whole-body SAR, however this approach may not be conservative over localised SAR, which
shall be assessed separately.

5.2 Assessment procedure
5.2.1 Reference and alternative methodologies
This standard describes measurement and calculation methodologies that may be used to establish the
compliance boundary. The current best evaluation techniques are assigned as the "reference"
methodologies to be applied in the case of dispute.


1)
This equation does not address thermal regulation in a live person.

---------------------- Page: 11 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 10 -
However, simpler-to-apply alternative methodologies may provide more restrictive results than the
reference methods and are therefore also acceptable. Compliance at a point of investigation may
therefore be established via any of the described methods.

Table 1 establishes the reference and alternative methodologies as described in this specification.

Table 1 – Reference and alternative methodologies
a,b
Applicable methodologies for each antenna region (see 8.2)
Reactive near-field Radiating near-field Far-field
Reference SAR evaluation SAR evaluation E-field or H-field
c,d c,d
Clause 7 Clause 7 calculation
f
Clause 8
First alternative E-field and H-field E-field or H-field E-field or H-field
measurement measurement measurement
e e
Clause 6 Clause 6 Clause 6
Second alternative E-field and H-field E-field or H-field None
calculation calculation
f e
Clause D.1 Clause 8
a
The reference methodology may be more complex to implement than the alternatives.
b
The alternative methodologies give valid conservative compliance assessments.
c
Methodology is not currently specified for whole body SAR evaluation above restricted power limits (see 7.1.2).
d
Localised SAR evaluation currently limited to
• 110 MHz ≤ frequency < 6 000 MHz,
• for investigation distances ≤ 400 mm.
e
Spatial averaging (Clause 9) provides a more accurate whole body evaluation of EM compliance than peak values, provided
localised SAR compliance is assessed.
f
See general investigation methods for E & H calculations in Clause D.1.
5.2.2 Alternative routes to determine compliance distances
Any of the alternative routes described in Figure 1 shall be used in accordance with Table 1 to establish if
a point of investigation is compliant or not. Any completed route can be demonstrated to assure
compliance to the "basic restriction" either directly or indirectly via compliance with the "reference level".

---------------------- Page: 12 ----------------------

SIST EN 50383:2010
- 11 - EN 50383:2010

Start
EM SAR
Evaluate by
SAR or EM
Reference
Level?
Assessment
within reactive
near-field of
Y
antenna?
N
Perform E, H, S measurement (6)
and/or calculation (8)
Y
% Compliance
Peak E, H, S
limit
value =
Reference
Level?
N
SAR
Select Whole
Body SAR or Perform Whole Body SAR
spatial Evaluation (7.1)
average?
Spatial
Ave.
Determine spatial average (9)
Whole Body
N
SAR = basic
restriction?
Spatial Ave.
N
2 2
E , H , S value
= Ref. Level?
Y
Y
Perform localised SAR
Evaluation (7.2)
Y
% Compliance
Localised
limit
N
SAR = basic
restriction?
Compliant at Non-Compliant
point of
at point of
investigation
investigation

Figure 1 - Alternative routes to establish compliance at a point of investigation

---------------------- Page: 13 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 12 -
5.2.3 Multiple Frequency bands
Where the EUT can be simultaneously operated on multiple frequency bands, the fractions of the
exposure limit shall be established on each band. The sum of all these fractions must be less than one for
overall compliance at the point of investigation to be established as described in normative references
(Clause 2). When this principle is applied to multi-band data, it will provide a clear algorithm specific for
the case under investigation that may provide a number of compliant solutions with different power
applied to each band for any given compliance boundary.

5.2.4 General requirements
The antenna is referenced by the centre of the rear reflector, in case of panel antennas, and by the centre
of the antenna in case of omni-directional antennas. For other configurations, appropriate references
must be defined.

Compliance boundary shall be established at least for the centre, the low-end and high-end frequencies
of each frequency band.

5.2.5 Compliance boundary
The compliance boundary may have a simple (e.g. parallelepiped, sphere or cylinder) or a more complex
shape. In any case, the points of investigation outside the compliance boundary shall be in compliance
with the limits. Moreover, the shape of the compliance boundary shall be accurately described in the
assessment report (Clause 10).
6 Electromagnetic field measurement
6.1 Introduction
This section describes the measurement procedures that may be used to assess, at points of
investigation, the electromagnetic field components (E and H and therefore the power density) radiated by
antennas.

The field measurements can be obtained either by surface or volume scanning.

The methods used are to measure directly or indirectly the E-field or H-field strength, deduce the field
distribution for a given input power and frequency.
6.2 Surface scanning method
6.2.1 Introduction
Methods to perform surface scanning could be, but are not limited to, far-field, compact range, and
planar, cylindrical or spherical near-field as long as the methodology is accurately defined and the
uncertainty criteria (Annexes B and E) are fulfilled.

---------------------- Page: 14 ----------------------

SIST EN 50383:2010
- 13 - EN 50383:2010
6.2.2 Spherical scanning method
6.2.2.1 General
Measurements of electric field amplitude, phase and polarisation are made at sufficient points on the
surface of a sphere surrounding the EUT to establish the parameters to model a set of isotropic sources
on that surface that will produce at the point of investigation the same field as the EUT. To make this
valid, the scanned spherical surface shall contain all the relevant energy that is radiated from the EUT.
The parameters of this set of isotropic-radiators are then used to calculate the field at the points of
investigation required in order to establish the compliance boundary.

The principle steps are summarised in Figure 2.


Start
Determine scanning radius & spherical sampling angles, set up test equipment
(6.2.2)
Measure phase & amplitude and polarization of EUT signals over a spherical surface of radius
R .
mes
(6.2.3)
Establish characteristics of equivalent isotropic-radiators on surface of radius R and determine
mes
E/H at point of investigation scaled for appropriate EUT power level(s)
(6.2.4)
Review uncertainty
(6.2.5)
Return field value at point of investigation
Chart 5.1

Figure 2 – Outline of the surface scanning methodology
6.2.3 Measurement equipment
6.2.3.1.1 General description
The surface scanning consists of an Equipment Under Test (EUT) mounted on an azimuthal positioner
and the probe(s) mounted on a support structure at distance R from the EUT. This method requires the
mes
ability to measure the phase of the signal. Detection shall consist of either one probe moved mechanically
along the structure or one probe array switched electronically in order to perform an angular elevation
scan of the electromagnetic fields.

Alternatively, the EUT can be moved to different elevation angles by means of an additional elevation
positioner.

The near-field antenna measurement system shall be configured according to Figure 3.

---------------------- Page: 15 ----------------------

SIST EN 50383:2010
EN 50383:2010 - 14 -

EUT
Z
Probe
(0, 0, 0)
Y
R mes
X
Positioner
Amp lifier Probep ositioning system Vector-receiver
control
synthesizer
Data acquisition
and PC co ntrol

Figure 3 – Block diagram of the near-field antenna measurement system

The following equipment is required:
- anechoic chamber;
- electric probe(s) (antenna(s));
- support structure for probe(s);
- supporting structure;
- vector receiver;
- synthesiser and amplifier(s);
- probe positioning system or probe array controller system;
- EUT positioning system.

A computer controls the measurement equipment located in the anechoic chamber. The computer shall
be placed so as not to influence the measurements.

The test shall be performed using probe antennas providing electric field measurements. The probe
antennas shall be accurately positioned to measure the electric field distributions in a spherical surface
around the EUT.

The measurement shall be carried out with a minimum of reflections from the environment in order to
simulate free space conditions.
6.2.3.1.2 Scanning equipment: positioning and orientation requirements
6.2.3.1.2.1 General criteria

The measurement system shall be able to scan a specified spherical surface of the test environment. In
order to provide sufficient data required combined with the resolution and accuracy needed for post-
processing;

− the radius R between the reference point of the EUT (0, 0, 0) and the probe(s) at each of the
mes
measurement points shall be chosen to satisfy the radius criteria (ref. 6.2.2.2.2.2) and shall be

established within λ/72 m i.e. a phase accuracy of better than 5 degrees [see reference Clause B.3].

---------------------- Page: 16 ----------------------

SIST EN 50383:2010
- 15 - EN 50383:2010
− the measurement system shall be able to provide measurements every δθ in elevation and δφ in
azimuth to satisfy the sampling criterion as defined in 6.2.2.2.2.3 with an angular accuracy better than
0,5 degrees.

The sampling of the whole spherical surface is achieved through the rotation of the EUT or the structure
supporting the probe(s). Several types of positioning systems are proposed in Annex B.

6.2.3.1.2.2 Radius criteria

R the distance between the reference point of the EUT at origin of rotation and the measurement
mes
probe(s) shall be the greater of

− R in order to minimise the impact of the non-radiating near fields where R depends upon the
min min
maximum dimension of the EUT and the wavelength λ Figure 4; and
− the distance required to ensure that the probes and measurement equipment is operating within
their calibrated level range for the power specifications of the EUT.


θ = 90° θ = 90°
Φ = 90° Φ = 90°
θ = 0° θ = 0°
λ R
min R
min
θ = 90° θ = 90°
a a
Φ = 0° Φ = 0°
Reference point Reference point
of the EUT
of the EUT
When a > λ, R = a + λ When a ≤ λ, R = 2λ
min min

Where:
a = the minimum radius of a sphere, centred at reference point, that will encompass the EUT.
Figure 4 – Minimum radius constraint


6.2.3.1.2.3 Sampling criterion

The sampling criterion (also commonly called Nyquist criteria) requires a maximum angular spacing of the
measurement points of λ/2 over the sphere circumscribing the EUT with radius R .
mes

The angles δφ (azimuth) and δθ (elevation) between adjacent measurements depend on the system but
shall compl
...