Railway applications - Fixed installations - D.C. switchgear -- Part 7: Measurement, control and protection devices for specific use in d.c. traction systems -- Section 3: Isolating voltage transducers and other voltage measuring devices

EN 50123-7-3 gives the requirements for isolating voltage transducers and other voltage measuring devices used in d.c. railway applications, fixed installations. This transducer is normally positioned between the voltage sensor on the live switchboard conductor or rail and the secondary device, giving galvanic insulation between the input and the output

Bahnanlagen - Ortsfeste Anlagen - Gleichstrom-Schalteinrichtungen -- Teil 7: Meß-, Steuer- und Schutzeinrichtungen in Gleichstrom-Bahnanlagen -- Hauptabschnitt 3: Spannungswandler und andere Meßeinrichtungen

Applications ferroviaires - Installations fixes - Appareillage à courant continu -- Partie 7: Appareils de mesure, de commande et de protection pour utilisation spécifique dans les systèmes de traction à courant continu -- Section 3: Transducteurs et autres appareils de mesure de la tension

Railway applications - Fixed installation - D.C. switchgear - Part 7: Measurement, control and protection devices for specific use in d.c. traction systems -Section 3: Isolating voltage transducers and other voltage mesuring devices

General Information

Status
Withdrawn
Publication Date
30-Nov-1999
Withdrawal Date
30-Apr-2003
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-May-2003
Due Date
01-May-2003
Completion Date
01-May-2003

Relations

Buy Standard

Standard
EN 50123-7-3:1999
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50123-7-3:1999
01-december-1999
Railway applications - Fixed installation - D.C. switchgear - Part 7: Measurement,
control and protection devices for specific use in d.c. traction systems -Section 3:
Isolating voltage transducers and other voltage mesuring devices
Railway applications - Fixed installations - D.C. switchgear -- Part 7: Measurement,
control and protection devices for specific use in d.c. traction systems -- Section 3:
Isolating voltage transducers and other voltage measuring devices
Bahnanlagen - Ortsfeste Anlagen - Gleichstrom-Schalteinrichtungen -- Teil 7: Meß-,
Steuer- und Schutzeinrichtungen in Gleichstrom-Bahnanlagen -- Hauptabschnitt 3:
Spannungswandler und andere Meßeinrichtungen
Applications ferroviaires - Installations fixes - Appareillage à courant continu -- Partie 7:
Appareils de mesure, de commande et de protection pour utilisation spécifique dans les
systèmes de traction à courant continu -- Section 3: Transducteurs et autres appareils de
mesure de la tension
Ta slovenski standard je istoveten z: EN 50123-7-
...