Fixed capacitors for use in electronic equipment -- Part 4: Sectional specification - Aluminium electrolytic capacitors with solid (MnO2) and non-solid electrolyte

This part of IEC 60384 applies to aluminium electrolytic capacitors with solid (MnO2) and nonsolid electrolyte primarily intended for d.c. applications for use in electronic equipment. It covers capacitors for long-life applications and capacitors for general-purpose applications. Capacitors for special-purpose applications may need additional requirements. Capacitors for fixed surface mount aluminium electrolytic capacitors are not included but they are covered by IEC 60384-18.

Festkondensatoren zur Verwendung in Geräten der Elektronik - Teil 4: Rahmenspezifikation - Aluminium-Elektrolyt-Kondensatoren mit festen (MnO2) und flüssigen Elektrolyten

Condensateurs fixes utilisés dans les équipements électroniques - Partie 4: Spécification intermédiaire - Condensateurs électrolytiques en aluminium à électrolyte solide (MnO2) et non solide

La CEI 60384-4:2007 s'applique aux condensateurs électrolytiques à l'aluminium, à électrolyte solide (MnO2) et non solide, destinés principalement aux applications en courant continu dans des équipements électroniques. Elle couvre les condensateurs utilisés dans des applications de longue durée de vie et les condensateurs utilisés dans des applications d'usage général. Les condensateurs pour des applications d'usage spécial peuvent nécessiter des exigences supplémentaires. Cette quatrième édition annule et remplace la troisième édition publiée en 1998, ainsi que son amendement 1 (2000). Cette édition constitue une révision mineure des tableaux, valeurs et références. La présente version bilingue, publiée en 2008, correspond à la version anglaise. Elle comprend le Corrigendum 1 (2007).

Fiksni kondenzatorji za uporabo v elektronski opremi – 4. del: Področna specifikacija - Aluminijski elektrolitski kondenzatorji s trdim (MnO2) in netrdim elektrolitom (IEC 60384-4:2007)

General Information

Status
Withdrawn
Publication Date
07-Nov-2007
Withdrawal Date
10-Oct-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
11-Oct-2019
Due Date
03-Nov-2019
Completion Date
11-Oct-2019

Relations

Buy Standard

Standard
EN 60384-4:2008
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60384-4:2008
01-januar-2008
)LNVQLNRQGHQ]DWRUML]DXSRUDERYHOHNWURQVNLRSUHPL±GHO3RGURþQD
VSHFLILNDFLMD$OXPLQLMVNLHOHNWUROLWVNLNRQGHQ]DWRUMLVWUGLP 0Q2 LQQHWUGLP
HOHNWUROLWRP ,(&
Fixed capacitors for use in electronic equipment - Part 4: Sectional specification -
Aluminium electrolytic capacitors with solid (MnO2) and non-solid electrolyte (IEC 60384-
4:2007)
Festkondensatoren zur Verwendung in Geräten der Elektronik - Teil 4:
Rahmenspezifikation - Aluminium-Elektrolyt-Kondensatoren mit festen (MnO2) und
flüssigen Elektrolyten (IEC 60384-4:2007)
Condensateurs fixes utilisés dans les équipements électroniques - Partie 4: Spécification
intermédiaire - Condensateurs électrolytiques en aluminium a électrolyte solide (MnO2)
et non solide (IEC 60384-4:2007)
Ta slovenski standard je istoveten z: EN 60384-4:2007
ICS:
31.060.50 Aluminijski elektrolitni Aluminium electrolytic
kondenzatorji capacitors
SIST EN 60384-4:2008 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 60384-4

NORME EUROPÉENNE
May 2007
EUROPÄISCHE NORM

ICS 31.060.50 Supersedes EN 130300:1998


English version


Fixed capacitors for use in electronic equipment -
Part 4: Sectional specification -
Aluminium electrolytic capacitors
with solid (MnO ) and non-solid electrolyte
2
(IEC 60384-4:2007)


Condensateurs fixes utilisés  Festkondensatoren zur Verwendung
dans les équipements électroniques - in Geräten der Elektronik -
Partie 4: Spécification intermédiaire - Teil 4: Rahmenspezifikation -
Condensateurs électrolytiques Aluminium-Elektrolyt-Kondensatoren
en aluminium à électrolyte solide (MnO ) mit festen (MnO ) und
2 2
et non solide flüssigen Elektrolyten
(CEI 60384-4:2007) (IEC 60384-4:2007)




This European Standard was approved by CENELEC on 2007-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60384-4:2007 E

---------------------- Page: 2 ----------------------

EN 60384-4:2007 - 2 -

Foreword
The text of document 40/1759/CDV, future edition 4 of IEC 60384-4, prepared by IEC TC 40, Capacitors
and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel Unique Acceptance
Procedure and was approved by CENELEC as EN 60384-4 on 2007-04-01.
This European Standard supersedes EN 130300:1998.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2008-01-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-04-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60384-4:2007 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 60384-4:2007
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

1)
IEC 60063 - Preferred number series for resistors and - -
capacitors


1) 2)
IEC 60068-1 - Environmental testing - EN 60068-1 1994
Part 1: General and guidance


1) 2)
IEC 60068-2-17 - Environmental testing - EN 60068-2-17 1994
Part 2-17: Tests - Test Q: Sealing


1) 2)
IEC 60068-2-54 - Environmental testing - EN 60068-2-54 2006
Part 2-54: Tests - Test Ta: Solderability
testing of electronic components by the
wetting balance method


IEC 60384-1 (mod) 1999 Fixed capacitors for use in electronic EN 60384-1 2001
equipment - + corr. October 2001
Part 1: Generic specification


1) 2)
IEC 60384-4-1 - Fixed capacitors for use in electronic EN 60384-4-1 2007
equipment -
Part 4-1: Blank detail specification - Fixed
aluminium electrolytic capacitors with
non-solid electrolyte - Assessment level EZ


1) 2)
IEC 60384-4-2 - Fixed capacitors for use in electronic EN 60384-4-2 2007
equipment -
Part 4-2: Blank detail specification - Fixed
aluminium electrolytic capacitors with solid
(MnO ) electrolyte - Assessment level EZ
2


1)
ISO 3 - Preferred numbers - Series of preferred - -
numbers




1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 4 ----------------------

INTERNATIONAL IEC


STANDARD 60384-4


QC 300300



Fourth edition

2007-03

Fixed capacitors for use in electronic equipment –
Part 4:
Sectional specification –
Aluminium electrolytic capacitors with
solid (MnO ) and non-solid electrolyte
2
© IEC 2007 ⎯ Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale W
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

---------------------- Page: 5 ----------------------

– 2 – 60384-4 © IEC:2007(E)
CONTENTS
FOREWORD.4

1 General .6
1.1 Scope.6
1.2 Object .6
1.3 Normative references .6
1.4 Information to be given in a detail specification .7
1.5 Terms and definitions .8
1.6 Marking .8
2 Preferred ratings and characteristics .9
2.1 Preferred characteristics .9
2.2 Preferred values of ratings .9
3 Quality assessment procedures.11
3.1 Primary stage of manufacture.11
3.2 Structurally similar components.11
3.3 Certified records of released lots.11
3.4 Qualification approval procedures .11
3.5 Quality conformance inspection.24
4 Test and measurement procedures.26
4.1 Pre-conditioning (for non-solid electrolyte capacitors only) .26
4.2 Visual examination and check of dimensions.26
4.3 Electrical tests.26
4.4 Robustness of terminations .29
4.5 Resistance to soldering heat .29
4.6 Solderability .29
4.7 Rapid change of temperature .30
4.8 Vibration.30
4.9 Bump .30
4.10 Shock.31
4.11 Climatic sequence .31
4.12 Damp heat, steady state.32
4.13 Endurance.32
4.14 Surge .33
4.15 Reverse voltage (if required by the detail specification) .34
4.16 Pressure relief (if required by the detail specification) .34
4.17 Storage at high temperature .35
4.18 Storage at low temperature (for non-solid electrolyte capacitors only) .35
4.19 Characteristics at high and low temperature .35
4.20 Charge and discharge (if required by the detail specification).35
4.21 High surge current (for solid electrolyte capacitors only and if required by the
detail specification) .36
4.22 Voltage transient overload.36

---------------------- Page: 6 ----------------------

60384-4 © IEC:2007(E) – 3 –

Table 1 – Fixed sample size test plan for qualification approval, assessment level EZ .13
Table 2 – Test schedule for qualification approval.14
Table 3 – Lot-by-lot inspection .25
Table 4 – Periodic inspection .25
Table 5 – Leakage current requirements .26
Table 6 – Amplitude and acceleration options .30
Table 7 – Preferred severities .31

---------------------- Page: 7 ----------------------

– 4 – 60384-4 © IEC:2007(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –

Part 4: Sectional specification –
Aluminium electrolytic capacitors with solid (MnO )
2
and non-solid electrolyte


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60384-4 has been prepared by IEC technical committee 40:
Capacitors and resistors for electronic equipment.
This fourth edition cancels and replaces the third edition published in 1998 and its
amendment 1 (2000). This edition constitutes a minor revision related to tables, figures and
references.
The text of this standard is based on the following documents:
CDV Report on voting
40/1759/CDV 40/1819/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

---------------------- Page: 8 ----------------------

60384-4 © IEC:2007(E) – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The QC number that appears on the front cover of this publication is the specification number
in the IEC Quality Assessment System for Electronic Components (IECQ).
The list of all parts of the IEC 60384 series, under the general title Fixed capacitors for use in
electronic equipment, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
The contents of the corrigendum of June 2007 have been included in this copy.

---------------------- Page: 9 ----------------------

– 6 – 60384-4 © IEC:2007(E)
FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –

Part 4: Sectional specification –
Aluminium electrolytic capacitors with solid (MnO )
2
and non-solid electrolyte



1 General
1.1 Scope
This part of IEC 60384 applies to aluminium electrolytic capacitors with solid (MnO ) and non-
2
solid electrolyte primarily intended for d.c. applications for use in electronic equipment. It
covers capacitors for long-life applications and capacitors for general-purpose applications.
Capacitors for special-purpose applications may need additional requirements.
Capacitors for fixed surface mount aluminium electrolytic capacitors are not included but they
are covered by IEC 60384-18.
1.2 Object
The principal object of this standard is to prescribe preferred ratings and characteristics and
to select from IEC 60384-1 the appropriate quality assessment procedures, tests and
measuring methods and to give general performance requirements for this type of capacitor.
Test severities and requirements prescribed in detail specifications referring to this sectional
specification shall be of equal or higher performance level, because lower performance levels
are not permitted.
1.3 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60063, Preferred number series for resistors and capacitors
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-17, Environmental testing – Part 2-17: Tests – Test Q: Sealing
IEC 60068-2-54, Environmental testing – Part 2-54: Tests – Test Ta: Solderability testing of
electronic components by the wetting balance method
IEC 60384-1:1999, Fixed capacitors for use in electronic equipment – Part 1: Generic
specification
IEC 60384-4-1, Fixed capacitors for use in electronic equipment – Part 4-1: Blank detail
specification – Fixed aluminium electrolyte capacitors with non-solid electrolyte – Assessment
level EZ
IEC 60384-4-2, Fixed capacitors for use in electronic equipment – Part 4-2: Blank detail
specification – Fixed aluminium electrolyte capacitors with solid (MnO2) electrolyte –
Assessment level EZ
ISO 3, Preferred numbers – Series of preferred numbers

---------------------- Page: 10 ----------------------

60384-4 © IEC:2007(E) – 7 –
1.4 Information to be given in a detail specification
Detail specifications shall be derived from the relevant blank detail specification.
Detail specifications shall not specify requirements inferior to those of the generic, sectional
or blank detail specification. When more severe requirements are included, they shall be
listed in 1.9 of the detail specification and indicated in the test schedules, for example, by an
asterisk.
NOTE The information given in 1.4.1 may, for convenience, be presented in tabular form.
The following information shall be given in each detail specification and the values quoted
shall preferably be selected from those given in the appropriate clause of this sectional
specification.
1.4.1 Outline drawing and dimensions
There shall be an illustration of the capacitor as an aid to easy recognition and for comparison
of the capacitor with others.
Dimensions and their associated tolerances, which affect interchangeability and mounting,
shall be given in the detail specification. All dimensions shall preferably be stated in
millimeters; however, when the original dimensions are given in inches, the converted metric
dimensions in millimetres shall be added.
Normally, the numerical values shall be given for the length of the body, the width and height
of the body and the wire spacing, or for cylindrical types, the body diameter, and the length
and diameter of the terminations. When necessary, for example, when a number of items
(capacitance values/voltage ranges) are covered by a detail specification, the dimensions and
their associated tolerances shall be placed in a table below the drawing.
When the configuration is other than described above, the detail specification shall state such
dimensional information as will adequately describe the capacitor. When the capacitor is not
designed for use on printed boards, this shall be clearly stated in the detail specification.
1.4.2 Mounting
The detail specification shall specify the method of mounting to be applied for normal use and
for the application of the vibration and the bump or shock tests. The capacitors shall be
mounted by their normal means. The design of the capacitor may be such that special
mounting fixtures are required in its use. In this case, the detail specification shall describe
the mounting fixtures and they shall be used in the application of the vibration and bump or
shock tests.
1.4.3 Ratings and characteristics
The ratings and characteristics shall be in accordance with the relevant clauses of this
specification, together with the following.
1.4.3.1 Rated capacitance range
See 2.2.1.
NOTE When products approved to the detail specification have different ranges, the following statement should
be added: "The range of values available in each voltage range is given in IEC QC 001005.".

---------------------- Page: 11 ----------------------

– 8 – 60384-4 © IEC:2007(E)
1.4.3.2 Particular characteristics
Additional characteristics may be listed when they are considered necessary to specify
adequately the component for design and application purposes.
1.4.3.3 Soldering
The detail specification shall prescribe the test methods, severities and requirements
applicable for the solderability and the resistance to soldering heat test.
1.4.4 Marking
The detail specification shall specify the content of the marking on the capacitor and on the
package. Deviations in 1.6 of this sectional specification shall be specifically stated.
1.5 Terms and definitions
For the purposes of this document, the following terms and definitions, in addition to the
applicable terms and definitions of IEC 60384-1, apply.
1.5.1
capacitance of an electrolytic capacitor
capacitance of an equivalent circuit having capacitance and resistance in series measured
with alternating current approximately sinusoidal waveform at a specified frequency
1.5.2
long-life grade capacitors
capacitors intended for applications where a high degree of stability of characteristics over a
long life is essential. The materials are chosen and the manufacture carried out so that
improved performance is obtained with consequent increase in life
1.5.3
general-purpose grade capacitors
capacitors intended for applications where the high performance level of long-life grade
capacitors is not required
1.5.4
reverse voltage (for polar capacitors only)
voltage applied to the capacitor terminals in the reverse polarity direction
1.6 Marking
According to 2.4 of IEC 60384-1, with the following details.
1.6.1 The information given in the marking is normally selected from the following list; the
relative importance of each item is indicated by its position in the list:
a) rated capacitance;
b) rated voltage (d.c. voltage may be indicated by the symbol:       or     );
c) category voltage and category temperatures (for long-life grade capacitors only);
d) polarity of the terminations: for multi-section capacitors, the rated capacitance and rated
voltage of the sections connected to each termination shall be shown in an unambiguous
way. The termination of a capacitor section which is intended for direct connection to the
rectifier (so-called reservoir section) shall be marked with the number 1 or with the colour
red;
e) tolerance on rated capacitance;

---------------------- Page: 12 ----------------------

60384-4 © IEC:2007(E) – 9 –
f) reference to the grade (for long-life grade capacitors only). The abbreviation LL may be
used for marking purposes;
g) year and month (or week) of manufacture;
h) manufacturer's name or trade mark;
i) climatic category;
j) manufacturer's type designation;
k) reference to the detail specification.
1.6.2 The capacitor shall be clearly marked with a), b), c), d), e) and f) above with as many
as possible of the remaining items as is considered necessary. Any duplication of information
in the marking on the capacitor should be avoided.
1.6.3 The package containing the capacitor(s) shall be clearly marked with all the
information listed in 1.6.1.
1.6.4 Any additional marking shall be so applied that no confusion can arise.
2 Preferred ratings and characteristics
2.1 Preferred characteristics
The values given in detail specifications shall preferably be selected from the following.
2.1.1 Preferred climatic categories
The capacitors covered by this specification are classified into climatic categories according
to the general rules given in IEC 60068-1.
The lower and upper category temperature and the duration of the damp-heat steady-state
test shall be chosen from the following.
Lower category temperature: –55 °C, –40 °C, –25 °C and –10 °C
Upper category temperature: +85 °C, +100 °C, +105 °C and +125 °C
Duration of the damp-heat steady-state test: 10, 21 and 56 days
The severities for the cold and dry heat tests are the lower and upper category temperatures
respectively.
2.2 Preferred values of ratings
2.2.1 Rated capacitance (C )
R
Preferred values of rated capacitance are chosen from the E3 series of IEC 60063 and their
decimal multiples.
If other values are needed, they shall preferably be chosen from the E6 series.

---------------------- Page: 13 ----------------------

– 10 – 60384-4 © IEC:2007(E)
2.2.2 Tolerance on rated capacitance
Preferred values of tolerances on rated capacitance are:
–10/+10 % –10/+75 %
–10/+30 % –10/+100 %
–10/+50 % –20/+20 %
2.2.3 Rated voltage (U )
R
Preferred values of rated direct voltages taken from the R5 and R10 series of ISO 3 are:
For voltage values <250 V: 1 V, 1,6 V, 2,5 V, 4 V, 6,3 V and their decimal
multiples (R5 series), also 35 V, 50 V, 80 V and
200 V;
For voltage values ≥250 V: 250 V, 315 V, 350 V, 400 V, 450 V and 500 V
(250 V, 315 V, 400 V and 500 V are in accordance
with the R10 series; 350 V and 450 V are permitted
in addition).
2.2.4 Category voltage (U )
C
The category voltage is equal to the rated voltage, unless otherwise stated in the detail
specification.
2.2.5 Ripple voltage
An alternating voltage may be applied provided that the peak voltage resulting from the
alternating voltage superimposed on the direct voltage does not exceed the value of rated
direct voltage and that the rated ripple current (see 2.2.8) and the permissible reverse voltage
(see detail specification) are not exceeded.
2.2.6 Reverse voltage
The permissible reverse voltage shall be given in the detail specification.
2.2.7 Surge voltage ratio
The surge voltage shall be 1,15 times the rated or category voltage for rated voltages ≤315 V
or 1,10 times the rated or category voltage for rated voltages >315 V.
See also 4.14.
2.2.8 Rated ripple current
The rated ripple current at 100 Hz or 120 Hz and at upper category temperature shall be
given in the detail specification. Alternatively, for capacitors for switched mode power supply
application, the rated ripple current shall be stated at the relevant frequency.
NOTE This value is determined by the dimensions of the capacitor and several other factors, for example, the
tangent of loss angle and the permissible temperature rise.