SIST EN 13126-6:2009
(Main)Building hardware - Requirements and test methods for windows and doors height windows - Part 6: Variable geometry stay hinges (with or without a friction stay)
Building hardware - Requirements and test methods for windows and doors height windows - Part 6: Variable geometry stay hinges (with or without a friction stay)
This part of prEN 13126 specifies requirements and test methods for durability, strength, security and function of mechanically operated variable geometry stay hinges (with or without a friction system).
By means of this European Standard, the user of recognized tested hardware can assume that with correct usage, the variable geometry stay hinges (with or without a friction system) for windows conform to prescribed requirements.
NOTE 1 This European Standard is applicable to variable geometry stay hinges (with or without a friction system) whether fitted with integral restrictors or not.
NOTE 2 Balancing stay arms/hinges do not represent a friction system.
NOTE 3 For the purposes of this European Standard, the friction system is achieved by friction pads or similar.
Baubeschläge - Anforderungen und Prüfverfahren für Fenster und Fenstertüren - Teil 6: Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem)
Dieser Teil von EN 13126 legt die Anforderungen und Prüfverfahren für die Dauerfunktionstüchtigkeit, Festigkeit, Schutzwirkung und Funktionsweise von mechanisch betätigten Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem) fest.
Mit Hilfe dieser Europäischen Norm kann der Anwender von anerkannten geprüften Baubeschlägen davon ausgehen, dass die Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem) für Fenster bei richtigem Gebrauch die vorgeschriebenen Anforderungen erfüllen.
ANMERKUNG 1 Diese Europäische Norm ist für Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem) anwendbar, die mit eingebauten Vorrichtungen zur Begrenzung des Öffnungswinkels versehen sein können, aber nicht müssen.
ANMERKUNG 2 Aussteller/Ausstellscheren stellen kein Friktionssystem dar.
ANMERKUNG 3 Für die Anwendung dieser Europäischen Norm wird das Friktionssystem durch Bremsplatten oder etwas Gleichartiges erreicht.
Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 6: Compas à friction à géométrie variable
La présente partie de l’EN 13126 spécifie les exigences et les méthodes d’essai relatives à l’endurance, à la résistance, à la sécurité des biens et au fonctionnement des compas mécaniques à friction à géométrie variable (avec ou sans système de friction).
La présente Norme européenne permet à l’utilisateur d’une ferrure éprouvée par essai de considérer que lorsqu’ils sont utilisés correctement, les compas à friction à géométrie variable (avec ou sans système de friction) des fenêtres, sont conformes aux exigences spécifiées.
NOTE 1 La présente Norme européenne est applicable aux compas à friction à géométrie variable (avec ou sans système de friction) qu’ils soient équipés ou non de limitateurs d’ouverture intégrés.
NOTE 2 Les compas ou bras de compas d’équilibrage ne constituent pas un système de friction.
NOTE 3 Pour les besoins de la présente Norme européenne, la friction est réalisée par des patins de friction ou des pièces similaires.
Stavbno okovje - Zahteve in preskusne metode za okna in zastekljena vrata - 6. del: Oporni tečaji z različno geometrijo (s sistemom trenja ali brez njega)
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baubeschläge - Anforderungen und Prüfverfahren für Fenster und Fenstertüren - Teil 6: Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem)Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 6: Compas à friction à géométrie variableBuilding hardware - Requirements and test methods for windows and doors height windows - Part 6: Variable geometry stay hinges (with or without a friction stay)91.190Stavbna opremaBuilding accessoriesICS:Ta slovenski standard je istoveten z:EN 13126-6SIST EN 13126-6:2009en,fr,de01-marec-2009SIST EN 13126-6:2009SLOVENSKI
STANDARDSIST-TS CEN/TS 13126-6:20051DGRPHãþD
SIST EN 13126-6:2009
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13126-6November 2008ICS 91.190Supersedes CEN/TS 13126-6:2004
English VersionBuilding hardware - Requirements and test methods for windowsand doors height windows - Part 6: Variable geometry stayhinges (with or without a friction stay)Quincaillerie pour le bâtiment - Exigences et méthodesd'essai des ferrures de fenêtres et portes-fenêtres - Partie6: Compas à friction à géométrie variable (avec ou sanssystème de friction)Baubeschlage - Beschläge für Fenster und Fenstertüren -Anforderungen und Prüfverfahren - Teil 6: Scheren mitveränderlicher Geometrie (mit oder ohne Friktionssystem);Deutsche Fassung EN 13126-6:2008This European Standard was approved by CEN on 5 October 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13126-6: ESIST EN 13126-6:2009
EN 13126-6:2008 (E) 2 Contents Page Foreword.4 1 Scope.6 2 Normative references.6 3 Terms and definitions.6 4 Classification.7 4.1 General.7 4.2 Category of use (1 – first digit).7 4.3 Durability (2 – second digit).7 4.4 Mass (3 – third digit).7 4.5 Fire resistance (4 – fourth digit).7 4.6 Safety in use (5 – fifth digit).7 4.7 Corrosion resistance (6 – sixth digit).8 4.8 Security (7 – seventh digit).8 4.9 Application (8 – eighth digit).8 4.10 Test sizes – size limitations (9 – ninth digit).8 4.11 Example of classification for variable geometry stay hinges (with or without a friction system – EN 13126-6).9 5 Requirements.10 5.1 General.10 5.2 Integrated restrictors.10 5.3 Additional requirements.10 5.3.1 Pull-in and pull-in abuse test.10 5.3.2 Friction test (where applicable).10 5.3.3 Obstructed track test.11 5.3.4 Ease of sash movement test.11 5.3.5 Durability test.11 5.3.6 Durability pull-in test.12 5.3.7 Simulated negative pressure test.12 5.3.8 Static load test.13 5.3.9 Additional load test.13 6 Test apparatus.13 6.1 General.13 6.2 Assembly.13 6.2.1 General.13 6.2.2 Fixing.13 6.3 Additional equipment.14 6.3.1 Block for pull-in abuse test.14 6.3.2 Steel cross for simulated negative pressure test.14 7 Test methods.14 7.1 Samples.14 7.2 Pull-in test.14 7.2.1 General.14 7.2.2 Pull-in test procedure.14 7.3 Friction test.15 7.3.1 General.15 7.3.2 Friction test procedure.15 7.4 Obstructed track test procedure.15 7.5 Pull-in abuse test.16 SIST EN 13126-6:2009
EN 13126-6:2008 (E) 3 7.6 Ease of sash movement test procedure.16 7.7 Durability test.16 7.7.1 General.16 7.7.2 Durability pull-in test procedure.17 7.8 Simulated negative pressure test.17 7.9 Static load test procedure.18 7.10 Additional load test procedure.18 7.11 Corrosion resistance.18 Annex A (normative)
Types of variable geometry stay hinges (with or without a friction system).19 Annex B (informative)
Test method diagrams.20 Annex C (normative)
Flow chart of test procedures.25
SIST EN 13126-6:2009
EN 13126-6:2008 (E) 4 Foreword This document (EN 13126-6:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. This document supersedes CEN/TS 13126-6:2004. This European Standard is one of a series of European Standards dedicated to building hardware products. A full contribution to the preparation of this European Standard has been made by the European manufacturers´ organization “ARGE” and national standards bodies. EN 13126 Building hardware — Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all types of hardware Part 2: Casement fastener handles1) Part 3: Manoeuvring fittings for espagnolette bolts/sliding button1) Part 4: Espagnolette bolts1) Part 5: Devices that restrict the opening of windows1) Part 6: Variable geometry stay hinges (with or without a friction system) Part 7: Finger catches Part 8: Tilt&Turn, Tilt-First and Turn-Only hardware Part 9: Pivot hinges1) Part 10: Arm balancing systems Part 11: Top hung projecting reversible hardware Part 12: Side hung projecting reversible hardware Part 13: Sash balances1) Part 14: Sash fasteners1) Part 15: Rollers for horizontal sliding and sliding folding windows and doors
1) To be revised, for the time being CEN/TS. SIST EN 13126-6:2009
EN 13126-6:2008 (E) 5 Part 16: Hardware for Lift&Slide windows and doors Part 17: Hardware for Tilt&Slide windows and doors Part 18: Fan light openers for windows and door height windows Part 19: Sliding Closing Devices (SCD) for windows and door height windows Informative Annex A of EN 13126-1:2006 gives detailed schedules of the elements of components of the 17 first parts of this European Standard. Informative Annex B of EN 13126-1:2006 gives schedules of the elements of components used on the 21 types of window opening functions. The performance tests incorporated in this European Standard are considered to be reproducible and as such will provide a consistent and objective assessment of the performance of these products throughout CEN Member States. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 13126-6:2009
EN 13126-6:2008 (E) 6 1 Scope This part of EN 13126 specifies requirements and test methods for durability, strength, security and function of mechanically operated variable geometry stay hinges (with or without a friction system). By means of this European Standard, the user of recognized tested hardware can assume that with correct usage, the variable geometry stay hinges (with or without a friction system) for windows conform to prescribed requirements. NOTE 1 This European Standard is applicable to variable geometry stay hinges (with or without a friction system) whether fitted with integral restrictors or not. NOTE 2 Balancing stay arms/hinges do not represent a friction system. NOTE 3 For the purposes of this European Standard, the friction system is achieved by friction pads or similar. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Building hardware — Corrosion resistance — Requirements and test methods EN 12519:2004, Windows and pedestrian doors — Terminology EN 13126-1:2006, Building hardware — Requirements and test methods for windows and doors height windows — Part 1: Requirements common to all types of hardware CEN/TS 13126-5, Building hardware — Requirements and test methods for windows and doors height windows — Part 5: Devices that restrict the opening of windows ISO 4520:1981, Chromate conversion coatings on electroplated zinc and cadmium coatings 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13126-1:2006 and
EN 12519:2004 and the following apply. NOTE The following terms and definitions apply to windows made of wood, PVC-u, aluminium or steel and their appropriate material combinations. 3.1 variable geometry stay hinge (with or without a friction system) hinge mechanism which has one or more link arms connecting the frame to the opening casement; the point about which the casement pivots being near the outer end of a link arm. The freedom of movement of the variable geometry stay hinge system is controlled by the friction between some or all of its moveable components NOTE Friction is usually applied either at the pivot points or between a sliding shoe and its track. SIST EN 13126-6:2009
EN 13126-6:2008 (E) 7 3.2 working stack height perpendicular distance between the outer faces of the frame plate and casement plate of a variable geometry stay hinge (with or without a friction system) 3.3 pull-in characteristic of the design of the variable geometry stay hinge (with or without a friction system), which maintains the non-locking edge of a casement in contact with the window frame or weather stripping when the casement fastener is closed 3.4 integrated restrictor mechanism that is an integral part of the variable geometry stay hinge (with or without a friction system) that limits the initial opening of the window 3.5 declared minimum opening distance measured between the nearest adjacent edges of the sash and frame as the outward movement, from fully closed to where the friction in a variable geometry stay hinge with a friction system is sufficient to conform to the requirements of 7.3 4 Classification 4.1 General The classification for variable geometry stay hinge (with or without a friction system) shall be in accordance with the requirements of EN 13126-1:2006, Clause 4. 4.2 Category of use (1 – first digit) No marking is required for the category of use in accordance with EN 13126-1:2006, 4.2. 4.3 Durability (2 – second digit) Grades shall be in accordance with EN 13126-1:2006, 4.3. 4.4 Mass (3 – third digit) Grades shall be in accordance with EN 13126-1:2006, 4.4. 4.5 Fire resistance (4 – fourth digit) One grade shall be identified in accordance with EN 13126-1:2006, 4.5. grade 0: no requirements. 4.6 Safety in use (5 – fifth digit) One grade shall be identified in accordance with EN 13126-1:2006, 4.6. grade 1: hardware shall conform to the requirements of EN 13126-1 and EN 13126-6. SIST EN 13126-6:2009
EN 13126-6:2008 (E) 8 4.7 Corrosion resistance (6 – sixth digit) Grades shall be in accordance with EN 13126-1:2006, 4.7. 4.8 Security (7 – seventh digit) No marking is required for the category of security in accordance with EN 13126-1:2006, 4.8. 4.9 Application (8 – eighth digit) The eighth digit shows “6/1”, “6/2” or “6/3” indicating the part of the standard which was used for testing the variable geometry stay hinges (with or without a friction system) and their common application to the following window assemblies in accordance with EN 13126-1:2006, 4.9. Three grades are identified: grade 6/1: indicating window operates on a horizontal axis of rotation: type C: bottom-hung window, inward opening or outward opening; type D: top-hung window, inward opening or outward opening; type H: projecting top-hung window, inward or outward opening; type J: projecting bottom-hung window, inward or outward opening; type U: top-hung, inward opening window multi-light; type V: bottom-hung, inward opening window multi-light; grade 6/2: indicating window operates on a vertical axis of rotation: type A: side-hung window inward opening; type B: side-hung window outward opening; grade 6/3: indicating the window operates on both horizontal and vertical axis of rotation. 4.10 Test sizes – size limitations (9 – ninth digit) The ninth digit shows the test sizes in accordance with EN 13126-1:2006, 4.10 as follows: S.W. 2) in mm / S.H. 3) in mm – tolerance of -2 mm/+0 mm EXAMPLE 1 200 S.W. × 900 S.H. Where a variable geometry stay hinge (with or without friction) operates on a horizontal axis of rotation, the test size is determined in accordance with Table 1. Where a variable geometry stay hinge (with or without friction) operates on a vertical axis of rotation, the test size is determined in accordance with Table 2.
2) S.W. = sash width 3) S.H. = sash height SIST EN 13126-6:2009
EN 13126-6:2008 (E) 9 Table 1 — Test window size for top hung variable geometry stay hinges Overall length of variable geometry stay hinge (mm) Sash width (mm) Sash height (mm) < 250 1 200 300 ≥ 251 ≤ 350 1 200 450 ≥ 351 ≤ 450 1 200 600 ≥ 451 ≤ 550 1 200 750 ≥ 551 ≤ 750 1 200 900 ≥ 751 1 200 1 200
Where a manufacturer specifies the maximum height of the casement on which the variable geometry stay hinge (with or without a friction system) is to be used, the variable geometry stay hinge (with or without a friction system) shall be tested on the largest size up to and including that height. Table 2 — Test window size for side hung variable geometry stay hinges Overall length of variable geometry stay hinge (mm) Sash width (mm) Sash height (mm) < 250 600 1 200 ≥ 251 ≤ 500 750 1 200 ≥ 501 900 1 200
Where a manufacturer specifies the maximum width of the casement on which the variable geometry stay hinge (with or without a fr
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Building hardware - Requirements and test methods for windows and doors height windows - Part 6: Variable geometry stay hinges (with or without a friction stay)Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 6: Compas à friction à géométrie variableBaubeschläge - Anforderungen und Prüfverfahren für Fenster und Fenstertüren - Teil 6: Scheren mit veränderlicher Geometrie (mit oder ohne Friktionssystem)91.190Stavbna opremaBuilding accessoriesICS:kSIST prEN 13126-6:2008en,fr,deTa slovenski standard je istoveten z:prEN 13126-601-junij-2008kSIST prEN 13126-6:2008SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMFINAL DRAFTprEN 13126-6April 2008ICS 91.190Will supersede CEN/TS 13126-6:2004
English VersionBuilding hardware - Requirements and test methods for windowsand doors height windows - Part 6: Variable geometry stayhinges (with or without a friction stay)Quincaillerie pour le bâtiment - Exigences et méthodesd'essai des ferrures de fenêtres et portes-fenêtres - Partie6: Compas à friction à géométrie variableBaubeschläge - Anforderungen und Prüfverfahren fürFenster und Fenstertüren - Teil 6: Scheren mitveränderlicher Geometrie (mit oder ohne Friktionssystem)This draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the TechnicalCommittee CEN/TC 33.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations whichstipulate the conditions for giving this European Standard the status of a national standard without any alteration.This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other languagemade by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has thesame status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice andshall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. prEN 13126-6:2008: E
prEN 13126-6:2008 (E) 2 Contents Page Foreword.4 1 Scope.6 2 Normative references.6 3 Terms and definitions.6 4 Classification.7 4.1 General.7 4.2 Category of use (1 – first digit).7 4.3 Durability (2 – second digit).7 4.4 Mass (3 – third digit).7 4.5 Fire resistance (4 – fourth digit).7 4.6 Safety in use (5 – fifth digit).7 4.7 Corrosion resistance (6 – sixth digit).8 4.8 Security (7 – seventh digit).8 4.9 Application (8 – eighth digit).8 4.10 Test sizes – size limitations (9 – ninth digit).8 4.11 Example of classification for variable geometry stay hinges (with or without a friction system – EN 13126-6).9 5 Requirements.10 5.1 General.10 5.2 Integrated restrictors.10 5.3 Additional requirements.10 5.3.1 Pull-in and pull-in abuse test.10 5.3.2 Friction test (where applicable).10 5.3.3 Obstructed track test.11 5.3.4 Ease of sash movement test.11 5.3.5 Durability test.11 5.3.6 Durability pull-in test.12 5.3.7 Simulated negative pressure test.12 5.3.8 Static load test.13 5.3.9 Additional load test.13 6 Test apparatus.13 6.1 General.13 6.2 Assembly.13 6.2.1 General.13 6.2.2 Fixing.13 6.3 Additional equipment.14 6.3.1 Block for pull-in abuse test.14 6.3.2 Steel cross for simulated negative pressure test.14 7 Test methods.14 7.1 Samples.14 7.2 Pull-in test.14 7.2.1 General.14 7.2.2 Pull-in test procedure.14 7.3 Friction test.15 7.3.1 General.15 7.3.2 Friction test procedure.15 7.4 Obstructed track test procedure.15 7.5 Pull-in abuse test.16
prEN 13126-6:2008 (E) 3 7.6 Ease of sash movement test procedure.16 7.7 Durability test.16 7.7.1 General.16 7.7.2 Durability pull-in test procedure.17 7.8 Simulated negative pressure test.17 7.9 Static load test procedure.18 7.10 Additional load test procedure.18 7.11 Corrosion resistance.18 Annex A (normative)
Types of variable geometry stay hinges (with or without a friction system).19 Annex B (informative)
Test method diagrams.20 Annex C (normative)
Flow chart of test procedures.25
prEN 13126-6:2008 (E) 4 Foreword This document (prEN 13126-6:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This document is currently submitted to the Unique Acceptance Procedure. A full contribution to the preparation of this European Standard has been made by the European manufacturers´ organization “ARGE” and national standards bodies. EN 13126 Building hardware — Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all types of hardware Part 2: Casement fastener handles1) Part 3: Manoeuvring fittings for espagnolette bolts/sliding button1) Part 4: Espagnolette bolts1) Part 5: Devices that restrict the opening of windows1) Part 6: Variable geometry stay hinges (with or without a friction system)1) Part 7: Finger catches Part 8: Tilt&Turn, Tilt-First and Turn-Only hardware Part 9: Pivot hinges1) Part 10: Arm balancing systems1) Part 11: Top hung projecting reversible hardware1) Part 12: Side hung projecting reversible hardware1) Part 13: Sash balances1) Part 14: Sash fasteners1) Part 15: Rollers for horizontal sliding and sliding folding windows and doors Part 16: Hardware for Lift&Slide windows and doors Part 17: Hardware for Tilt&Slide windows and doors Informative Annex A of EN 13126-1:2006 gives detailed schedules of the elements of components of the 17 parts of this European Standard.
1) To be revised, for the time being CEN/TS.
prEN 13126-6:2008 (E) 5 Normative Annex B of EN 13126-1:2006 gives schedules of the elements of components used on the 21 types of window opening functions. The performance tests incorporated in this European Standard are considered to be reproducible and as such will provide a consistent and objective assessment of the performance of these products throughout CEN Member States.
prEN 13126-6:2008 (E) 6 1 Scope This part of prEN 13126 specifies requirements and test methods for durability, strength, security and function of mechanically operated variable geometry stay hinges (with or without a friction system). By means of this European Standard, the user of recognized tested hardware can assume that with correct usage, the variable geometry stay hinges (with or without a friction system) for windows conform to prescribed requirements. NOTE 1 This European Standard is applicable to variable geometry stay hinges (with or without a friction system) whether fitted with integral restrictors or not. NOTE 2 Balancing stay arms/hinges do not represent a friction system. NOTE 3 For the purposes of this European Standard, the friction system is achieved by friction pads or similar. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Building hardware — Corrosion resistance — Requirements and test methods EN 12519:2004, Windows and pedestrian doors — Terminology EN 13126-1:2006, Building hardware — Requirements and test methods for windows and doors height windows — Part 1: Requirements common to all types of hardware CEN/TS 13126-5, Building hardware — Requirements and test methods for windows and doors height windows — Part 5: Devices that restrict the opening of windows ISO 4520:1981, Chromate conversion coatings on electroplated zinc and cadmium coatings 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13126-1:2006 and
EN 12519:2004 and the following apply. NOTE The following terms and definitions apply to windows made of wood, PVC-u, aluminium or steel and their appropriate material combinations. 3.1 variable geometry stay hinge (with or without a friction system) hinge mechanism which has one or more link arms connecting the frame to the opening casement; the point about which the casement pivots being near the outer end of a link arm. The freedom of movement of the variable geometry stay hinge system is controlled by the friction between some or all of its moveable components NOTE Friction is usually applied either at the pivot points or between a sliding shoe and its track.
prEN 13126-6:2008 (E) 7 3.2 working stack height perpendicular distance between the outer faces of the frame plate and casement plate of a variable geometry stay hinge (with or without a friction system) 3.3 pull-in characteristic of the design of the variable geometry stay hinge (with or without a friction system), which maintains the non-locking edge of a casement in contact with the window frame or weather stripping when the casement fastener is closed 3.4 integrated restrictor mechanism that is an integral part of the variable geometry stay hinge (with or without a friction system) that limits the initial opening of the window 3.5 declared minimum opening distance measured between the nearest adjacent edges of the sash and frame as the outward movement, from fully closed to where the friction in a variable geometry stay hinge with a friction system is sufficient to conform to the requirements of 7.3 4 Classification 4.1 General The classification for variable geometry stay hinge (with or without a friction system) shall be in accordance with the requirements of EN 13126-1:2006, Clause 4. 4.2 Category of use (1 – first digit) No marking is required for the category of use in accordance with EN 13126-1:2006, 4.2. 4.3 Durability (2 – second digit) Grades shall be in accordance with EN 13126-1:2006, 4.3. 4.4 Mass (3 – third digit) Grades shall be in accordance with EN 13126-1:2006, 4.4. 4.5 Fire resistance (4 – fourth digit) One grade shall be identified in accordance with EN 13126-1:2006, 4.5. grade 0: no requirements. 4.6 Safety in use (5 – fifth digit) One grade shall be identified in accordance with EN 13126-1:2006, 4.6. grade 1: The hardware shall conform to the requirements of EN 13126-1 and EN 13126-6.
prEN 13126-6:2008 (E) 8 4.7 Corrosion resistance (6 – sixth digit) Grades shall be in accordance with EN 13126-1:2006, 4.7. 4.8 Security (7 – seventh digit) No marking is required for the category of security in accordance with EN 13126-1:2006, 4.8. 4.9 Application (8 – eighth digit) The eighth digit shows “6/1”, “6/2” or “6/3” indicating the part of the standard which was used for testing the variable geometry stay hinges (with or without a friction system) and their common application to the following window assemblies in accordance with EN 13126-1:2006, 4.9. Three grades are identified: grade 6/1: indicating window operates on a horizontal axis of rotation: type C: bottom-hung window, inward opening or outward opening; type D: top-hung window, inward opening or outward opening; type H: projecting top-hung window, inward or outward opening; type J: projecting bottom-hung window, inward or outward opening; type U: top-hung, inward opening window multi-light; type V: bottom-hung, inward opening window multi-light; grade 6/2: indicating window operates on a vertical axis of rotation: type A: side-hung window inward opening; type B: side-hung window outward opening; grade 6/3: indicating the window operates on both horizontal and vertical axis of rotation. 4.10 Test sizes – size limitations (9 – ninth digit) The ninth digit shows the test sizes in accordance with EN 13126-1:2006, 4.10 as follows: S.W. 2) in mm / S.H. 3) in mm – tolerance of -2 mm/+0 mm EXAMPLE 1 200 S.W. × 900 S.H. Where a variable geometry stay hinge (with or without friction) operates on a horizontal axis of rotation, the test size is determined in accordance with Table 1. Where a variable geometry stay hinge (with or without friction) operates on a vertical axis of rotation, the test size is determined in accordance with Table 2.
2) S.W. = sash width 3) S.H. = sash height
prEN 13126-6:2008 (E) 9 Table 1 — Test window size for top hung variable geometry stay hinges Overall length of variable geometry stay hinge (mm) Sash width (mm) Sash height (mm) < 250 1 200 300 ≥ 251 ≤ 350 1 200 450 ≥ 351 ≤ 450 1 200 600 ≥ 451 ≤ 550 1 200 750 ≥ 551 ≤ 750 1 200 900 ≥ 751 1 200 1 200
Where a manufacturer specifies the maximum height of the casement on which the variable geometry stay hinge (with or without a friction system) is to be used, the variable geometry stay hinge (with or without a friction system) shall be tested on the largest size up to and including that height. Table 2 — Test window size for side hung variable geometry stay hinges Overall length of variable geometry stay hinge (mm) Sash width (mm) Sash height (mm) < 250 600 1 200 ≥ 251 ≤ 500 750 1 200 ≥ 501 900 1 200
Where a manufacturer specifies the maximum width of the casement on which the variable geometry stay hinge (with or without a friction system) is to be used, the variable geometry stay hinge (with or without a friction system) shall be tested on the largest size up to and including that width. 4.11 Example of classification for variable geometry stay hinges (with or without a friction system – EN 13126-6) An example classification is shown in Table 3. Table 3 — Example of classification for variable geometry stay hinges 1 2 3 4 5 6
...