SIST EN 1024:2012
(Main)Clay roofing tiles for discontinuous laying - Determination of geometric characteristics
Clay roofing tiles for discontinuous laying - Determination of geometric characteristics
This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings - Product definitions and specifications.
Tondachziegle für überlappende Verlegung - Bestimmung der geometrischen Kennwerte
Diese Europäische Norm legt die Prüfverfahren für die Bestimmung der geometrischen Kennwerte von Tondachziegeln fest, die in EN 1304, Dachziegel und Formziegel — Begriffe und Produktanforderungen definiert sind.
Tuiles de terre cuite pour pose en discontinu - Détermination des caractéristiques géométriques
La présente Norme européenne spécifie les méthodes de détermination des caractéristiques géométriques des tuiles en terre cuite telles que définies dans l'EN 1304, Tuiles et accessoires en terre cuite - Définitions et spécifications des produits.
Opečni strešniki - Ugotavljanje geometrijskih značilnosti
Ta evropski standard določa metode za ugotavljanje geometrijskih značilnosti opečnih strešnikov, iz standarda EN 1304, Opečni strešniki in fazonski kosi, Definicije in specifikacije izdelkov.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Tondachziegle für überlappende Verlegung - Bestimmung der geometrischen KennwerteTuiles de terre cuite pour pose en discontinu - Détermination des caractéristiques géométriquesClay roofing tiles for discontinuous laying - Determination of geometric characteristics91.100.25Ceramic building productsICS:Ta slovenski standard je istoveten z:EN 1024:2012SIST EN 1024:2012en,fr,de01-julij-2012SIST EN 1024:2012SLOVENSKI
STANDARDSIST EN 1024:19981DGRPHãþD
SIST EN 1024:2012
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1024
March 2012 ICS 91.100.25 Supersedes EN 1024:1997English Version
Clay roofing tiles for discontinuous laying - Determination of geometric characteristics
Tuiles de terre cuite pour pose en discontinu - Détermination des caractéristiques géométriques
Tondachziegle für überlappende Verlegung - Bestimmung der geometrischen Kennwerte This European Standard was approved by CEN on 22 January 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1024:2012: ESIST EN 1024:2012
EN 1024:2012 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Symbols .44Test pieces .55Tests methods .56Test report . 17Annex A (informative)
Example of twist measurement device for tiles with sidelock and headlock, tiles with sidelock only and overlapping tiles . 18 SIST EN 1024:2012
EN 1024:2012 (E) 3 Foreword This document (EN 1024:2012) has been prepared by Technical Committee CEN/TC 128 “Roof covering products for discontinuous laying and products for wall cladding”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2012, and conflicting national standards shall be withdrawn at the latest by September 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1024:1997. This European Standard is one of the series of standards dealing with clay roofing tiles as listed below: EN 1304, Clay roofing tiles and fittings Products definitions and specifications EN 538, Clay roofing tiles for discontinuous laying Flexural strength test EN 539, Clay roofing tiles for discontinuous laying Determination of physical characteristic This European Standard includes: an informative annex Figure A.1 – Example of twist measurement device for tiles with sidelock and headlock, tiles with sidelock only and overlapping tiles.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 1024:2012
EN 1024:2012 (E) 4 1 Scope This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings Product definitions and specifications. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1304, Clay tiles and fittings Product definitions and specifications 3 Symbols L1 maximum distance when measuring covering dimensions (length) in millimetres (mm); L2 minimum distance when measuring covering dimensions (length) in millimetres (mm); l1 maximum distance when measuring covering dimensions (width) in millimetres (mm); l2 minimum distance when measuring covering dimensions (width) in millimetres (mm); L mean cover length in millimetres (mm); LM maximum cover length in millimetres (mm); l mean cover width in millimetres (mm); lM maximum cover width in millimetres (mm); H difference in height from the measuring point at the support bar or height in relation to a reference plane in millimetres (mm); C twist coefficient in percent; A tile length as declared by the manufacturer in millimetres (mm); B tile width as declared by the manufacturer in millimetres (mm); hd height of camber as declared by the manufacturer in millimetres (mm); hm measured height of camber in millimetres (mm); R camber in percentage; ∆h Ghm - hdG absolute value in millimetres (mm); LT total length of the tile in millimetres (mm); lT total width of the tile in millimetres (mm); LA measurement base in longitudinal direction in millimetres (mm); LB measurement base in transverse direction in millimetres (mm); E1 distance between the internal edges of an over - and under- tile at one of its extremities in millimetres (mm); E2 distance between the internal edges of an over - and under- tile at the other extremity in millimetres (mm). SIST EN 1024:2012
EN 1024:2012 (E) 5 4 Test pieces The measurement of geometric characteristics are carried out on 10 test pieces, each of which constitutes a whole tile, except for the measurement of cover dimensions, which requires 24 tiles. 5 Tests methods 5.1 Determination of dimensional characteristics 5.1.1 Individual dimensions1)
5.1.1.1 Apparatus The tests are made with a measuring apparatus with a precision of at least one millimetre. 5.1.1.2 Procedure After removing any surplus clay from the edges, the measurements shall be taken, both transversely and longitudinally along the centre of the tile unless another measuring position has been specified by the manufacturer (see Figure 1). The dimensions are expressed to the nearest whole millimetre.
Key 1 tile Figure 1 – Principle for measuring individual dimensions 5.1.1.3 Expression of results The arithmetic means of the lengths and widths of the 10 tested tiles and the differences expressed as a percentage of these mean values in relation to the values A and B declared by the manufacturer shall be calculated and noted in the test report.
1) EN 1304 specifies to which type of tiles these measurements apply. SIST EN 1024:2012
EN 1024:2012 (E) 6 5.1.2 Overlap dimensions (margins)1) 5.1.2.1 Principle The mean overlap dimensions are determined longitudinally and transversely. They are measured as indicated in Figure 2. NOTE Certain tile models can only be measured in one direction.
Key 1 mean cover length 1.1 open position 1.2 closed position 2 mean cover width 2.1 open position 2.2 closed position Figure 2 – Principle for measuring cover dimensions 5.1.2.2 Number of test pieces 24 tiles are required for the measurements. 5.1.2.3 Apparatus The tests are carried out with a measuring apparatus with a precision of at least 1 mm. SIST EN 1024:2012
EN 1024:2012 (E) 7 5.1.2.4 Procedure The tiles are laid upside down in two rows on a flat surface, and interlocked with one another so as to form a stable unit. Certain types of tiles may require laying the right way up. The tiles are interlocked longitudinally and pulled apart individually to measure the maximum distance between two corresponding points on the first and the eleventh tile, i.e. L1, the maximum length. Following this, the tiles are taken up, then relaid and interlocked. They are pushed together individually as closely as possible to carry out the measurement of the minimum distance (L2) following the procedure described above. Take again the same measurements, but this time, transversely in order to obtain the values l1 and l2. With regard to tiles with a variable overlap, determine only the measurement of cover in the open position, L1 (longitudinally), l1 (transversely). NOTE This method is not relevant to some types of tiles designed to be laid broken jointed. 5.1.2.5 Expression of results The mean cover length (L) is obtained from the following formula: L
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.