SIST EN 300 417-5-2 V1.1.1:2003
(Main)Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 5-2: Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement (ICS) proforma specification
Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 5-2: Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement (ICS) proforma specification
ICS proforma for ETS 300 417-5-1.
Prenos in multipleksiranje (TM) – Generične zahteve za prenosno funkcionalnost opreme – 5-2. del: Funkcije plasti poti pri pleziohroni digitalni hierarhiji (PDH) – Proforma specifikacija izjave o skladnosti izvedbe (ICS)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 300 417-5-2 V1.1.1:2003
01-december-2003
3UHQRVLQPXOWLSOHNVLUDQMH70±*HQHULþQH]DKWHYH]DSUHQRVQRIXQNFLRQDOQRVW
RSUHPH±GHO)XQNFLMHSODVWLSRWLSULSOH]LRKURQLGLJLWDOQLKLHUDUKLML3'+±
3URIRUPDVSHFLILNDFLMDL]MDYHRVNODGQRVWLL]YHGEH,&6
Transmission and Multiplexing (TM); Generic requirements of transport functionality of
equipment; Part 5-2: Plesiochronous Digital Hierarchy (PDH) path layer functions;
Implementation Conformance Statement (ICS) proforma specification
Ta slovenski standard je istoveten z: EN 300 417-5-2 Version 1.1.1
ICS:
33.040.20 Prenosni sistem Transmission systems
SIST EN 300 417-5-2 V1.1.1:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
---------------------- Page: 2 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
ETSI EN 300 417-5-2 V1.1.1 (1999-08)
European Standard (Telecommunications series)
Transmission and Multiplexing (TM);
Generic requirements of transport functionality of equipment;
Part 5-2: Plesiochronous Digital Hierarchy (PDH)
path layer functions;
Implementation Conformance Statement (ICS)
proforma specification
---------------------- Page: 3 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
2 ETSI EN 300 417-5-2 V1.1.1 (1999-08)
Reference
DEN/TM-01015-5-2 (3v19iico.PDF)
Keywords
ICS, SDH, PDH , testing, transmission
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
Individual copies of this ETSI deliverable
can be downloaded from
http://www.etsi.org
If you find errors in the present document, send your
comment to: editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1999.
All rights reserved.
ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
3 ETSI EN 300 417-5-2 V1.1.1 (1999-08)
Contents
Intellectual Property Rights.13
Foreword .13
Introduction .14
1 Scope.15
2 References.15
3 Definitions and abbreviations .16
3.1 Definitions . 16
3.2 Abbreviations. 16
4 Conformance to this ICS proforma specification .19
Annex A (normative): ICS proforma for EN 300 417-5-1.20
A.1 Guidance for completing the ICS proforma.20
A.1.1 Purposes and structure . 20
A.1.2 Abbreviations and conventions. 20
A.1.3 Instructions for completing the ICS proforma . 22
Annex B (normative): ICS proforma for P4e Path Layer .23
B.1 Identification of the implementation.23
B.1.1 Date of the statement . 23
B.1.2 Implementation Under Test (IUT) identification . 23
B.1.3 System Under Test (SUT) identification. 24
B.1.4 Product supplier. 24
B.1.5 Client . 25
B.1.6 ICS contact person. 25
B.2 Identification of the ETS.26
B.3 Global statement of conformance of P4e Path Layer .26
B.4 P4e Path Layer Functions .26
B.4.0 P4e Path Layer Description . 26
B.4.0.1 Characteristic Information. 28
B.4.0.2 Adapted information . 29
B.4.1 P4e Connection function. 29
B.4.2 P4e Trail Termination functions . 29
B.4.2.1 P4e Trail Termination Source P4e_TT_So . 29
B.4.2.1.1 Processes (P4e_TT_So). 29
B.4.2.2 P4e Trail Termination Sink P4e_TT_Sk. 30
B.4.2.2.1 Management information (P4e_TT_Sk). 30
B.4.2.2.2 Processes (P4e_TT_Sk). 30
B.4.2.2.3 Defects (P4e_TT_Sk) . 31
B.4.2.2.4 Consequent actions (P4e_TT_Sk) . 31
B.4.2.2.5 Defect Correlations (P4e_TT_Sk). 31
B.4.2.2.6 Performance monitoring (P4e_TT_Sk) . 32
B.4.3 P4e Adaptation functions. 32
B.4.3.1 P4e to P31x Adaptation Source P4e/P31x_A_So/i . 32
B.4.3.1.1 Management information (P4e/P31x_A_So). 32
B.4.3.1.2 Processes (P4e/P31x_A_So) . 33
B.4.3.2 P4e to P31x Adaptation Sink P4e/P31x_A_Sk/i. 34
B.4.3.2.1 Management information (P4e/P31x_A_Sk). 34
B.4.3.2.2 Processes (P4e/P31x_A_Sk). 34
B.4.3.2.3 Consequent actions (P4e/P31x_A_Sk) . 36
ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
4 ETSI EN 300 417-5-2 V1.1.1 (1999-08)
B.4.3.3 P4e to P31e Adaptation Source P4e/P31e_A_So/i. 36
B.4.3.3.1 Management information (P4e/P31e_A_So). 36
B.4.3.3.2 Processes (P4e/P31e_A_So). 37
B.4.3.4 P4e to P31e Adaptation Sink P4e/P31e_A_Sk/i . 38
B.4.3.4.1 Management information(P4e/P31e_A_Sk) . 38
B.4.3.4.2 Processes (P4e/P31e_A_Sk). 39
B.4.3.4.3 Defects (P4e/P31e_A_Sk) . 41
B.4.3.4.4 Consequent actions (P4e/P31e_A_Sk) . 41
B.4.3.4.5 Defect Correlations (P4e/P31e_A_Sk) . 41
B.4.3.5 P4e to P31s Adaptation Source P4e/P31s_A_So/i. 42
B.4.3.5.1 Management information (P4e/P31s_A_So/i) . 42
B.4.3.5.2 Processes (P4e/P31s_A_So/i). 42
B.4.3.6 P4e to P31s Adaptation Sink P4e/P31s_A_Sk/i. 43
B.4.3.6.1 Management information (P4e/P31s_A_Sk) . 44
B.4.3.6.2 Processes (P4e/P31s_A_Sk). 44
B.4.3.6.3 Defects (P4e/P31s_A_Sk) . 46
B.4.3.6.4 Consequent actions (P4e/P31s_A_Sk). 47
B.4.3.6.5 Defect correlation (P4e/P31s_A_Sk). 47
B.4.4 P4e Layer Monitoring Functions . 47
B.4.4.1 P4e Layer Non-intrusive Monitoring Function P4em_TT_Sk .47
B.4.4.1.1 Management information (P4em_TT_Sk). 47
B.4.4.1.2 Processes . 48
B.4.4.1.3 Defects (P4em_TT_Sk) . 48
B.4.4.1.4 Consequent actions (P4em_TT_Sk) . 49
B.4.4.1.5 Defect Correlations (P4em_TT_Sk). 49
B.4.4.1.6 Performance Monitoring (P4em_TT_Sk). 49
B.4.5 P4e PDH Equipment Clock Adaptation Source P4e_PEC. 49
B.4.5.1 Processes (P4e_PEC) . 50
Annex C (normative): ICS proforma for P31e Path Layer .51
C.1 Identification of the implementation.51
C.1.1 Date of the statement . 51
C.1.2 Implementation Under Test (IUT) identification . 51
C.1.3 System Under Test (SUT) identification. 51
C.1.4 Product supplier. 52
C.1.5 Client . 52
C.1.6 ICS contact person. 53
C.2 Identification of the ETS.53
C.3 Global statement of conformance of P31e Path Layer .54
C.4 P31e Path Layer Functions .54
C.4.0 P31e Path Layer Description . 54
C.4.0.1 Characteristic Information. 56
C.4.0.2 Adapted information . 56
C.4.1 P31e Connection function. 56
C.4.2 P31e Trail Termination functions . 56
C.4.2.1 P31e Trail Termination Source P31e_TT_So . 57
C.4.2.1.1 Processes (P31e_TT_So). 57
C.4.2.2 P31e Trail Termination Sink P31e_TT_Sk. 57
C.4.2.2.1 Management information (P31e_TT_Sk). 57
C.4.2.2.2 Processes (P31e_TT_Sk). 58
C.4.2.2.3 Defects (P31e_TT_Sk) . 59
C.4.2.2.4 Consequent actions (P31e_TT_Sk) . 59
C.4.2.2.5 Defect Correlations (P31e_TT_Sk). 59
C.4.2.2.6 Performance monitoring (P31e_TT_Sk) . 59
C.4.3 P31e Adaptation functions. 60
C.4.3.1 P31e to P22x Adaptation Source P31e/P22x_A_So/i . 60
C.4.3.1.1 Management information (P31e/P22x_A_So). 60
C.4.3.1.2 Processes (P31e/P22x_A_So) . 60
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
5 ETSI EN 300 417-5-2 V1.1.1 (1999-08)
C.4.3.2 P31e to P22x Adaptation Sink P31e/P22x_A_Sk/i. 61
C.4.3.2.1 Management information (P31e/P22x_A_Sk). 62
C.4.3.2.2 Processes (P31e/P22x_A_Sk). 62
C.4.3.2.3 Consequent actions (P31e/P22x_A_Sk) . 64
C.4.3.3 P31e to P22e Adaptation Source P31e/P22e_A_So/i. 64
C.4.3.3.1 Management information (P31e/P22e_A_So/i). 64
C.4.3.3.2 Processes (P31e/P22e_A_So/i) . 65
C.4.3.4 P31e to P22e Adaptation Sink P31e/P22e_A_Sk/i . 66
C.4.3.4.1 Management information(P31e/P22e_A_Sk/i). 66
C.4.3.4.2 Processes (P31e/P22e_A_Sk). 66
C.4.3.4.3 Defects (P31e/P22e_A_Sk) . 69
C.4.3.4.4 Consequent actions (P31e/P22e_A_Sk) . 69
C.4.3.4.5 Defect Correlations (P31e/P22e_A_Sk) . 69
C.4.4 P31e Layer Monitoring Functions . 70
C.4.4.1 P31e Layer Non-intrusive Monitoring Function P31em_TT_Sk . 70
C.4.4.1.1 Management information (P31em_TT_Sk). 70
C.4.4.1.2 Processes . 70
C.4.4.1.3 Defects (P31em_TT_Sk) . 71
C.4.4.1.4 Consequent actions (P31em_TT_Sk) . 71
C.4.4.1.5 Defect Correlations (P31em_TT_Sk). 71
C.4.4.1.6 Performance Monitoring (P31em_TT_Sk). 72
C.4.5 P31e PDH Equipment Clock Adaptation Source P31e_PEC. 72
C.4.5.1 Processes (P31em_TT_Sk) . 72
Annex D (normative): ICS proforma for P22e Path Layer .73
D.1 Identification of the implementation.73
D.1.1 Date of the statement . 73
D.1.2 Implementation Under Test (IUT) identification . 73
D.1.3 System Under Test (SUT) identification. 74
D.1.4 Product supplier. 74
D.1.5 Client . 75
D.1.6 ICS contact person. 75
D.2 Identification of the ETS.75
D.3 Global statement of conformance of P22e Path Layer .76
D.4 P22e Path Layer Functions .76
D.4.0 P22e Path Layer Description . 76
D.4.0.1 Characteristic Information. 77
D.4.0.2 Adapted information . 78
D.4.1 P22e Connection function. 78
D.4.2 P22e Trail Termination functions . 78
D.4.2.1 P22e Trail Termination Source P22e_TT_So . 78
D.4.2.1.1 Processes (P22e_TT_So). 78
D.4.2.2 P22e Trail Termination Sink P22e_TT_Sk. 79
D.4.2.2.1 Management information (P22e_TT_Sk). 79
D.4.2.2.2 Processes (P22e_TT_Sk). 79
D.4.2.2.3 Defects (P22e_TT_Sk) . 80
D.4.2.2.4 Consequent actions (P22e_TT_Sk) . 80
D.4.2.2.5 Defect Correlations (P22e_TT_Sk). 80
D.4.2.2.6 Performance monitoring (P22e_TT_Sk) . 81
D.4.3 P22e Adaptation functions. 81
D.4.3.1 P22e to P12x Adaptation Source P22e/P12x_A_So/i . 81
D.4.3.1.1 Management information (P22e/P12x_A_So). 81
D.4.3.1.2 Processes (P22e/P12x_A_So) . 81
D.4.3.2 P22 . 82
D.4.3.2.1 Management information (P22e/P12x_A_Sk). 83
D.4.3.2.2 Processes (P22e/P12x_A_Sk). 83
D.4.3.2.3 Consequent actions (P22e/P12x_A_Sk) . 85
D.4.3.3 P22e to P12s Adaptation Source P22e/P12s_A_So/i. 85
ETSI
---------------------- Page: 7 ----------------------
SIST EN 300 417-5-2 V1.1.1:2003
6 ETSI EN 300 417-5-2 V1.1.1 (1999-08)
D.4.3.3.1 Management information (P22e/P12s_A_So/i) . 85
D.4.3.3.2 Processes (P22e/P12s_A_So/i). 85
D.4.3.4 P22e to P12s Adaptation Sink P22e/P12s_A_Sk/i. 86
D.4.3.4.1 Management information (P22e/P12s_A_Sk) . 87
D.4.3.4.2 Processes (P22e/P12s_A_Sk). 87
D.4.3.4.3 Defects (P22e/P12s_A_Sk) . 89
D.4.3.4.4 Consequent actions (P22e/P12s_A_Sk). 90
D.4.3.4.5 Defect correlation (P22e/P12s_A_Sk). 90
D.4.4 P22e Layer Monitoring Functions . 90
D.4.4.1 P22e Layer Non-intrusive Monitoring Function P22em_TT_Sk . 90
D.4.4.1.1 Management information (P22em_TT_Sk). 90
D.4.4.1.2 Processes . 91
D.4.4.1.3 Defects (P22em_TT_Sk) . 92
D.4.4.1.4 Consequent actions (P22em_TT_Sk) . 92
D.4.4.1.5 Defect Correlations (P22em_TT_Sk). 92
D.4.4.1.6 Performance Monitoring (P22em_TT_Sk). 92
D.4.5 P22e PDH Equipment Clock Adaptation Source P22e_PEC. 93
D.4.5.1 Processes (P22em_TT_Sk) . 93
Annex E (normative): ICS proforma for P12s Path Layer.94
E.1 Identification of the implementation.94
E.1.1 Date of the statement .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.