SIST EN 300 386 V1.6.1:2012
(Main)Electromagnetic compatibility and Radio spectrum Matters (ERM) - Telecommunication network equipment - ElectroMagnetic Compatibility (EMC) requirements
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Telecommunication network equipment - ElectroMagnetic Compatibility (EMC) requirements
The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are:
Switching equipment. Such equipment includes:
- local telephone exchanges;
- remote switching concentrators;
- international switches;
- telex switches;
- network packet switches;
- base station controllers, radio network controllers;
- network servers and gateways.
Non-radio transmission equipment and ancillary equipment. Such equipment includes:
- multiplexers;
- line equipment and repeaters, e.g. equipment for:
_ Synchronous Digital Hierarchy (SDH);
_ Plesiochronous Digital Hierarchy (PDH);
_ Asynchronous Transfer Mode (ATM);
such as:
_ Digital Cross Connect systems;
_ network terminations;
_ transmission equipment used in the access network like xDSL.
Power supply equipment. Such equipment includes:
- central power plant;
- end of suite power supplies;
- uninterruptible power supplies;
- stabilized AC power supplies; and
- other dedicated telecommunication network power supplies;
but excludes equipment which is uniquely associated with or integrated in other equipment.
Supervisory equipment. Such equipment includes:
- network management equipment;
- operator access maintenance equipment;
- traffic measurement systems;
- line test units;
- functional test units.
The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested.
Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) - Oprema za telekomunikacijsko omrežje - Zahteve za elektromagnetno združljivost (EMC)
Ta dokument vključuje zahteve glede elektromagnetne združljivosti (EMC) za neradijsko opremo v okviru javnega telekomunikacijskega omrežja, ki zagotavlja telekomunikacijo med omrežnimi priključnimi točkami (NTP) (tj. razen za terminalsko opremo, ki presega omrežne priključne točke). Primeri takšne opreme so:
Stikalna oprema. Ta oprema vključuje:
– lokalne telefonske centrale;
– daljinske stikalne koncentratorje;
– mednarodna stikala;
– teleks stikala;
– omrežna paketna stikala;
– krmilnike bazne postaje, krmilnike radijskega omrežja;
– omrežne strežnike in prehode.
Oprema za neradijski prenos in pomožna oprema. Ta oprema vključuje:
– multiplekserje;
– linijsko opremo in ponavljalnike, npr. opremo za:
_ sinhrono digitalno hierarhijo (SDH);
_ pleziohrono digitalno hierarhijo (PDH);
_ asinhroni prenosni način (ATM);
kot so:
_ sistemi digitalnega prevezovanja;
_ omrežni zaključki;
_ oprema za prenos, ki se uporablja v dostopovnem omrežju, kot je xDSL.
Napajalna oprema. Ta oprema vključuje:
– centralno elektrarno;
– električno napajanje na koncu niza;
– napajalniki za neprekinjeno napajanje;
– napajalniki za stabilizirano napajanje z izmeničnim tokom; in
– drugi namenski telekomunikacijski omrežni napajalniki;
vendar izključuje opremo, ki je edinstveno povezana z drugo opremo ali vključena vanjo.
Nadzorna oprema. Ta oprema vključuje:
– opremo za upravljanje omrežja;
– opremo za ohranjanje dostopa operaterja;
– sisteme za merjenje prometa;
– linijske preskusne enote;
– funkcijske preskusne enote.
Funkcija nadzora se lahko izvaja s samostojno opremo ali v okviru druge telekomunikacijske omrežne opreme. Če je funkcija nadzora del telekomunikacijske omrežne opreme, se lahko zmogljivost oceni hkrati z drugimi funkcijami (kot sta preklapljanje in prenos) med preskusom elektromagnetne združljivosti. Lokacije okoljske razvrstitve, uporabljene v tem dokumentu, se nanašajo na TR 101 651 [i.22]. Zahteve iz tega dokumenta so bile izbrane tako, da se zagotovi ustrezna stopnja odpornosti aparatov, ki spadajo na področje uporabe tega dokumenta. Vendar stopnje ne zajemajo izjemnih primerov, ki se lahko zgodijo na kateri koli lokaciji, čeprav je verjetnost majhna. V posebnih primerih lahko nastopijo okoliščine, v katerih lahko stopnje motenj presežejo stopnje preskusa odpornosti iz tega dokumenta. V teh primerih je morda treba uporabiti posebne ukrepe za ublažitev. Oprema za splošne namene, ki se uporablja kot del telekomunikacijskega omrežja, je lahko vključena v okvir drugih standardov. Take opreme ni treba dodatno oceniti, če ti drugi standardi v celoti vključujejo zahteve iz tega dokumenta. Oprema za kabelske razdelilne sisteme, namenjena le za televizijo in zvočne signale, kot je določena v standardu EN 50083-2 [3], ter optični ojačevalniki, kot so določeni v priporočilih ITU-T G.661 [i.6] in G.662 [i.7], ne spadajo na področje uporabe tega dokumenta. Oprema lahko ima različne funkcije, tj. stikalna oprema ima lahko tudi funkcije prenosa, oprema za prenos ima lahko zmogljivost shranjevanja itd. Vse razpoložljive funkcije EUT je treba preskusiti.
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Elektromagnetna združljivost in zadeve v zvezi z radijskim spektrom (ERM) - Oprema za telekomunikacijsko omrežje - Zahteve za elektromagnetno združljivost (EMC)Electromagnetic compatibility and Radio spectrum Matters (ERM) - Telecommunication network equipment - ElectroMagnetic Compatibility (EMC) requirements33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in generalICS:Ta slovenski standard je istoveten z:EN 300 386 Version 1.6.1SIST EN 300 386 V1.6.1:2012en01-oktober-2012SIST EN 300 386 V1.6.1:2012SLOVENSKI
STANDARD
SIST EN 300 386 V1.6.1:2012
ETSI EN 300 386 V1.6.1 (2012-09) Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements
Harmonized European Standard SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 2
Reference REN/ERM-EMC-312 Keywords EMC, network, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2012. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 3 Contents Intellectual Property Rights . 6 Foreword . 6 1 Scope . 7 2 References . 8 2.1 Normative references . 8 2.2 Informative references . 10 3 Definitions and abbreviations . 12 3.1 Definitions . 12 3.2 Abbreviations . 14 4 Installation environment . 14 5 Immunity: test methods . 15 5.1 Electrostatic discharge . 15 5.2 Electrical fast transients/burst . 15 5.3 Surges . 15 5.3.1 Signal line ports . 15 5.3.2 AC power ports . 15 5.4 Immunity to continuous conducted signals . 16 5.4.1 Low frequency (≤ 150 kHz) . 16 5.4.2 Radio frequency (> 150 kHz) . 16 5.4.2.1 AC power port . 16 5.4.2.2 DC power port . 16 5.4.2.3 Signal line port . 16 5.5 Immunity to radiated electromagnetic fields . 16 5.6 Immunity to power supply disturbances: AC and DC power ports . 16 5.6.1 Test of immunity to low frequency disturbances: AC power ports . 16 5.6.2 Test of immunity to low frequency disturbances: DC power ports . 16 6 Emission: test methods . 17 6.1 AC power port . 17 6.2 DC power port . 17 6.3 Telecommunication Port . 17 6.4 Radiated emission. 17 7 Test levels and limits . 18 7.1 Emission . 18 7.1.1 Enclosure port, Radiated electromagnetic field emissions . 18 7.1.2 AC ports . 18 7.1.2.1 Conducted emissions . 18 7.1.2.2 Current harmonics . 18 7.1.2.3 Voltage fluctuations . 18 7.1.3 DC ports, Conducted emissions . 18 7.1.4 Telecommunication ports, Conducted emissions . 18 7.2 Immunity . 19 7.2.1 Equipment operating in telecommunication centres . 19 7.2.1.1 Telecommunication centres, enclosure port . 19 7.2.1.2 Telecommunication centres, ports for outdoor signal lines . 20 7.2.1.3 Telecommunication centres, ports for indoor signal lines . 21 7.2.1.4 Telecommunication centres, AC power ports . 22 7.2.1.5 Telecommunication centres, DC power ports . 22 7.2.2 Equipment operating in locations other than telecommunication centres . 23 7.2.2.1 Other than telecommunication centres, enclosure port . 23 7.2.2.2 Other than telecommunication centres, ports for outdoor signal lines . 24 7.2.2.3 Other than telecommunication centres, ports for indoor signal lines . 25 7.2.2.4 Other than telecommunication centres, AC power ports . 26 SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 4 7.2.2.5 Other than telecommunication centres, DC power ports . 27 8 General test configuration . 28 9 General operational conditions during testing . 28 9.1 Equipment configuration . 28 9.2 Operation of multimedia network equipment . 29 10 General immunity conditions . 29 10.1 General performance criteria . 29 11 Switching equipment specific requirements . 30 11.1 Test configuration. 30 11.2 Operational conditions . 31 11.2.1 Emission . 32 11.2.2 Immunity . 32 11.3 Specific immunity performance criteria . 32 11.3.1 Digital port performance criteria . 32 11.3.1.1 Performance criterion A (continuous phenomena) . 32 11.3.1.2 Performance criterion B (transient phenomena). 32 11.3.1.3 Performance criterion C (interruptions) . 32 11.3.2 Analogue port performance criteria . 33 11.3.2.1 Performance criterion A (continuous phenomena) . 33 11.3.2.2 Performance criterion B (transient phenomena). 33 11.3.2.3 Performance criterion C (interruptions) . 33 12 Transmission equipment specific requirements . 33 12.1 Test configuration. 33 12.2 Operational conditions . 34 12.2.1 Emission . 34 12.2.2 Immunity . 34 12.3 Specific immunity performance criteria . 34 12.3.1 Digital signal ports . 34 12.3.1.1 Performance criterion A (continuous phenomena) . 35 12.3.1.2 Performance criterion B (transient phenomena). 35 12.3.1.3 Performance criterion C (interruptions) . 35 12.3.2 Analogue voice frequency signal ports . 35 12.3.2.1 Performance criterion A (continuous phenomena) . 35 12.3.2.2 Performance criterion B (transient phenomena). 35 12.3.3 SDH and PDH interfaces . 35 12.3.3.1 Tributary and aggregate interfaces . 35 12.3.4 ISDN interfaces . 36 12.3.4.1 Primary rate access ISDN interfaces . 36 12.3.4.2 Network termination NT1 for ISDN "U" interfaces . 36 12.3.4.3 Basic access ISDN interfaces . 36 12.3.5 Analogue interfaces . 36 12.3.5.1 Trunk interfaces and leased line interfaces . 36 12.3.5.2 Subscriber interfaces . 36 12.3.6 V.10, V.11, V.24, V.28, V.36, X.24 and similar V.- and X.- series interfaces . 36 12.3.7 Ethernet and packet-data interfaces . 36 12.3.7.1 Performance criterion A (continuous phenomena) . 36 12.3.7.2 Performance criterion B (transient phenomena). 36 12.3.8 Service and maintenance interfaces . 36 12.3.9 Synchronization interfaces . 37 12.3.9.1 Performance criterion A (continuous phenomena) . 37 12.3.9.2 Performance criterion B (transient phenomena). 37 12.3.10 Remote alarm interfaces . 37 12.3.10.1 Performance criterion A (continuous phenomena) . 37 12.3.10.2 Performance criterion B (transient phenomena). 37 12.4 Digital Subscriber Line (DSL) Access Systems . 37 12.4.1 Test configuration . 37 12.4.2 Operational conditions . 38 12.4.3 Immunity . 38 12.4.4 Specific Immunity performance criteria . 38 SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 5 12.4.4.1 Performance Criteria A (continuous phenomena) . 39 12.4.4.2 Performance Criteria B (transient phenomena) . 39 12.4.4.3 Performance Criteria C (interruptions). 39 13 Power supply equipment specific conditions . 39 13.1 Test configuration. 39 13.2 Operational conditions . 40 13.2.1 Emission . 40 13.2.2 Immunity . 40 13.3 Specific immunity performance criteria . 41 13.3.1 Alternating current secondary interface . 41 13.3.1.1 Performance criterion A (continuous phenomena) . 41 13.3.1.2 Performance criterion B (transient phenomena). 41 13.3.2 Direct current secondary interface . 42 13.3.2.1 Performance criterion A (continuous phenomena) . 42 13.3.2.2 Performance criterion B (transient phenomena). 42 13.3.3 Control/signal interface . 42 13.3.4 Tertiary supply interface . 42 14 Supervisory equipment specific conditions . 42 14.1 Test configuration. 42 14.2 Operational conditions . 43 14.3 Specific immunity performance criteria . 43 14.3.1 Performance criterion A (continuous phenomena) . 43 14.3.2 Performance criterion B (transient phenomena) . 43 Annex A (normative): Surges: test method for ports of signal lines remaining within the building . 44 A.1 Test set-up for signal ports . 44 Annex B (informative): Evaluation of test results . 46 Annex C (informative): Guidance on EMC performance requirements and methods of measurement for RF ports (in the sense of EN 50083 series) of multimedia network equipment . 48 Annex D (informative): Bibliography . 49 History . 50
SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 6 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http://ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Harmonized European Standard (EN) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Directive 98/34/EC [i.23] as amended by Directive 98/48/EC [i.30]. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility ("the EMC Directive") (2004/108/EC [i.24]).
National transposition dates Date of adoption of this EN: 10 August 2012 Date of latest announcement of this EN (doa): 30 November 2012 Date of latest publication of new National Standard or endorsement of this EN (dop/e):
31 May 2013 Date of withdrawal of any conflicting National Standard (dow): 30 November 2015
SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 7 1 Scope The present document covers the EMC requirements for non-radio equipment intended to be used within a public telecommunications network, which provides telecommunications between Network Termination Points (NTPs) (i.e. excluding terminal equipment beyond the NTPs). Examples of such equipment are: • Switching equipment. Such equipment includes: - local telephone exchanges; - remote switching concentrators; - international switches; - telex switches; - network packet switches; - base station controllers, radio network controllers; - network servers and gateways. • Non-radio transmission equipment and ancillary equipment. Such equipment includes: - multiplexers; - line equipment and repeaters, e.g. equipment for:
Synchronous Digital Hierarchy (SDH);
Plesiochronous Digital Hierarchy (PDH);
Asynchronous Transfer Mode (ATM); such as:
Digital Cross Connect systems;
network terminations;
transmission equipment used in the access network like xDSL. • Power supply equipment. Such equipment includes: - central power plant; - end of suite power supplies; - uninterruptible power supplies; - stabilized AC power supplies; and - other dedicated telecommunication network power supplies; but excludes equipment which is uniquely associated with or integrated in other equipment. SIST EN 300 386 V1.6.1:2012
ETSI ETSI EN 300 386 V1.6.1 (2012-09) 8 • Supervisory equipment. Such equipment includes: - network management equipment; - operator access maintenance equipment; - traffic measurement systems; - line test units; - functional test units. The function of supervision may either be performed by independent equipment or form part of other telecommunication network equipment. If the function of supervision forms part of a telecommunication network equipment, the performance may be evaluated simultaneously with other functions (such as switching and transmission) during EMC testing. The environmental classification locations used in the present document refers to TR 101 651 [i.22]. The requirements of the present document have been selected to ensure an adequate level of immunity for the apparatus covered by the scope of the present document. The levels do not, however, cover extreme cases which may occur at any location but with a low probability of occurrence. In special cases, situations may arise where the levels of disturbance may exceed the immunity test levels specified in the present document. In these instances, special mitigation measures may have to be employed. General purpose equipment, which is used as a part of a telecommunication network, may be covered by the scope of other standards. For such equipment, if those other standards fully cover the requirements of the present document, no further assessment is necessary. Equipment for cabled distribution systems intended only for television and sound signals as defined in EN 50083-2 [3] and optical amplifiers as defined in ITU-T Recommendations G.661 [i.6] and G.662 [i.7] are outside the scope of the present document. Equipment may provide different functions, i.e. switching equipment may also provide transmission functions and transmission equipment may provide storage capabilities etc. All available functions of the EUT are to be tested. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.