SCOPE
1.1 This specification covers requirements for safety vacuum release systems (SVRS) for use on both residential and commercial swimming pools, spas, hot tubs, and wading pools.  
1.2 This specification is intended to reduce the risk of entrapment by providing a rapid detection and rapid release of vacuum or preventing a high vacuum altogether when a person becomes entrapped at the suction outlet serving a pumping system.  
1.3 This specification only applies to systems equipped with pumps of similar horsepower and flow rating to those actually tested.  
1.4 SVRS units manufactured, previously sold and installed, prior to the publication of this specification, which were compliant to the previous version of this specification, are to be considered compliant with this specification.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 The following safety hazards caveat pertains only to the test methods section, Section 5, of this specification.  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    7 pages
    English language
  • Technical specification
    7 pages
    English language

SCOPE
1.1 This safety performance specification provides requirements for safety in design and installation when using a suction-limiting vent system for suction entrapment prevention in swimming pools, spas, hot tubs, or wading pools.  
1.2 The purpose of the vent is to relieve the vacuum at the suction outlet(s) caused by any blockage of the suction outlet(s). The vent is intended to prevent body entrapment at the suction outlet(s) and may also mitigate limb entrapment. It is not intended to prevent other injuries caused by the suction outlet(s) such as hair entrapment, mechanical entrapment, or evisceration.  
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

  • Technical specification
    4 pages
    English language

SCOPE
1.1 This specification covers requirements for safety vacuum release systems (SVRS) for use on swimming pools, spas, hot tubs, and wading pools.
1.2 This specification is intended to reduce the risk of drowning or entrapment by providing a rapid detection and rapid release of vacuum or preventing a dangerous vacuum altogether when a person becomes entrapped at the suction outlet serving a pumping system.
1.3 The values stated in customary English units are to be regarded as the standard. Any values in parentheses are given for information only.
1.4 The following safety hazards caveat pertains only to the test methods section, Section 5, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Technical specification
    6 pages
    English language

SCOPE
1.1 This safety performance specification provides requirements for safety in design and installation when using a suction-limiting vent system for suction entrapment prevention in swimming pools, spas, hot tubs, or wading pools.
1.2 The purpose of the vent is to relieve the vacuum at the suction outlet(s) caused by any blockage of the suction outlet(s). The vent is intended to prevent body entrapment at the suction outlet(s) and may also mitigate limb entrapment. It is not intended to prevent other injuries caused by the suction outlet(s) such as hair entrapment, mechanical entrapment, or evisceration.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Technical specification
    4 pages
    English language

SCOPE
1.1 This specification covers requirements for safety vacuum release systems (SVRS) for use on swimming pools, spas, hot tubs, and wading pools.
1.2 This specification is intended to reduce the risk of drowning or entrapment by providing a rapid detection and rapid release of vacuum or preventing a dangerous vacuum altogether when a person becomes entrapped at the suction outlet serving a pumping system.
1.3 The values stated in customary English units are to be regarded as the standard. Any values in parentheses are given for information only.
1.4 The following safety hazards caveat pertains only to the test methods section, Section 5, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Technical specification
    6 pages
    English language

Frequently Asked Questions

F15.51 is a Technical Committee within ASTM International. It is named "Safety Vacuum Release Systems for Swimming Pools, Spas and Hot Tubs". This committee has published 5 standards.

F15.51 develops ASTM standards in the area of Information technology. Currently, there are 5 published standards from this technical committee.

ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.

A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...