CEN/TC 277 - Suspended ceilings
To establish EN's on suspended ceilings for building and civil engineering works covering items such as terminology, fire, acoustics, thermal performances and also specifications for installations and application. To coordinate the outgoing work in relation to suspended ceilings in other functional and material related TC's.
Spuščeni stropovi
To establish EN's on suspended ceilings for building and civil engineering works covering items such as terminology, fire, acoustics, thermal performances and also specifications for installations and application. To coordinate the outgoing work in relation to suspended ceilings in other functional and material related TC's.
General Information
This European Standard covers membranes, individual substructure components, substructure kits and suspended ceiling kits intended to be placed on the market. It covers suspended ceilings sold as a complete kit, substructures placed on the market as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity and for the marking of the products to the requirements of this European Standard.
In the absence of any other European Standard, this European Standard specifies dimensions, tolerances and, where relevant, performance requirements, for commonly available ceiling substructures and membrane components.
This European Standard covers the following characteristics:
- reaction to fire;
- fire resistance (suspended ceiling kits only);
- release and/or content of dangerous substances:
- release of asbestos (content) (suspended ceiling kits and membrane components only);
- release of formaldehyde (suspended ceiling kits and membrane components only);
- other dangerous substances;
- shatter properties (safe breakage)/impact resistance (for suspended ceiling kits and membrane components of brittle materials in suspended ceiling kits only);
- flexural tensile strength;
- load bearing capacity, tolerances and dimensions;
- electrical safety (as adequacy of the product to avoid electrocution from installations that may be part of the assembled ceiling, using electricity, such as ventilation devices and lighting);
- direct airborne sound insulation (suspended ceiling kits only);
- sound absorption (suspended ceiling kits and membrane components only);
- thermal conductivity (suspended ceiling kits and membrane components only);
- susceptibility to the growth of harmful micro-organisms;
- resistance to fixings (relevant for components that are mechanically fixed);
- durability of flexural tensile strength and load bearing capacity against moisture.
This European Standard also covers the following requirements:
- colour and light reflectance;
- installation.
This European Standard does not cover the following:
- ceiling substructures and membrane component covered by other harmonised European Standards, for insitu formed ceilings, covered by other European technical specifications, for which it is the installer, not the component manufacturer, who takes responsibility for ensuring that the complete installed suspended ceiling meets any regulatory requirements to which it is subject;
- stretched ceilings covered by EN 14716;
- ceilings in mobile buildings, caravans and other forms of transportation;
- characteristics needed for special applications, for which additional characteristics other than covered by this European Standard would need to be complied with;
- suspended ceilings intended for uses in ceilings subject to water penetration requirements;
- ceilings used externally where requirements other than covered by this standard would apply (tunnels, canopies, petrol stations, arcades, open sports facilities, car parks, etc.);
- heavy duty suspended ceilings or their supporting construction (e.g. ceilings that can be walked on);
- ceilings made from fire protective boards;
- the performance and health and safety requirements of light fittings and other features that, optionally, are included in the suspended ceiling;
- panels from materials covered in other harmonised European standards already prepared by CEN/TC 241 and CEN/TC 112 (see NOTE 2);
- anchors covered by other European technical specifications.
NOTE 1 These standards have been developed by CEN/TC 241 under the Mandate M/106 “Gypsum products” and by CEN/TC 112 under the Mandate M/113 “Wood-based panels”.
This European Standard also gives certain specifications for the installed suspended ceiling system (see NOTE 1).
NOTE 2 There are two reasons for this:
- Standard129 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers membranes, individual substructure components, substructure kits and suspended ceiling kits when these are placed on the market. This European Standard also gives certain specifications for the installed suspended ceiling system, for two reasons: the individual components and kits may have to meet certain requirements in order for the installed system to be able to meet the requirement when the system is installed, and because it is appropriate, for ease of reference, to give both component/kit requirement and installed system requirement in the same document, given the relationship between them.
This European Standard provides information for the various parties responsible for designing, manufacturing and specifying/selecting suspended ceilings used for interior applications in general building and civil engineering structures. It covers suspended ceilings sold as a complete kit, substructures sold as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity of the products to the requirements of this European Standard.
In the absence of any other European Standard, this European Standard specifies dimensions, tolerances and, where relevant, performance requirements, for commonly available ceiling substructures and membrane components.
This European Standard does not cover the following:
ceiling substructures and membrane component covered by other harmonised European Standards, for in-situ formed ceilings, covered by other European technical specifications, for which it is the installer, not the component manufacturer, who takes responsibility for ensuring that the complete installed suspended ceiling meets any regulatory requirements to which it is subject;
stretched ceilings covered by EN 14716;
ceilings in mobile buildings, caravans and other forms of transportation;
characteristics
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
The European Standard provides information for the various parties responsible for designing, manufacturing and specifying/selecting suspended ceilings used for interior applications in general building and civil engineering structures. It covers suspended ceilings sold as a complete kit (including, optionally, light fittings and other features), substructures sold as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity of the products to the requirements of this standard.
In the absence of any other European Standard, this standard specifies dimensions, tolerances and, where relevant, performance requirements, for commonly available ceiling substructures and membrane components.
- Standard81 pagesEnglish languagesale 10% offe-Library read for1 day