Specifies the requirements for insulation fault location systems which localize insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically d.c. circuits having nominal voltages up to 1000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1500 V d.c., independent of the measuring principle. This part is to be used in conjunction with IEC 61557-1.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for measuring equipment applied to the testing of the effectiveness of protective measures by regular disconnections of residual current protective devices (RCD) in TT and TN systems.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for insulation monitoring devices which permanently monitor the insulation resistance to earth of unearthed IT a.c. and d.c. systems, and for IT a.c. systems with galvanically connected d.c. circuits.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for equipment for measuring the resistance of earth conductors, protective earth conductors and conductors for equipotential bonding including their connections and terminals.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for equipment for measuring the earth resistance using an a.c. voltage

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for measuring equipment applied to testing th e phase sequence in three-phase distribution systems. Indication of the phase sequence may be mechanical, visual and/or audible.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for equipment for measuring the loop impedance between a phase conductor and the protective conductor or between a phase conductor and neutral or between two phase conductors by using the voltage drop when the circuit under test is loaded.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for equipment for measuring the insulation resistance of equipment and installations in the de-energized state.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies the general requirements for measuring and monitoring equipment for testing the electrical safety in low voltage distribution systems with nominal voltages up to 1000 V a.c. and 1500 V d.c.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day