WG 8 - TC 22/SC 22E/WG 8
TC 22/SC 22E/WG 8
General Information
IEC 62909-1:2025 specifies general and safety aspects of bi-directional grid-connected power converters (GCPC), consisting of a grid-side inverter with two or more types of DC power ports on the application side with system voltages not exceeding 1 000 V AC or 1 500 V DC.
This document can also be used for the special case of a multiple DC power port GCPC used in an application requiring only one DC power port.
This document considers general aspects such as terminology, specifications, performance, system architecture, as well as safety requirements.
This document does not cover:
- uninterruptible power supply (UPS) systems, which fall under the scope of the IEC 62040 series,
- power conversion equipment for use in photovoltaic systems, which fall under the scope of the IEC 62109 series, and
- bi-directional power converters to charge or discharge the batteries located within electric vehicles or in the charging station, which fall under the scope of the IEC 61851 series.
NOTE 1 The external system (e.g. energy management system, utility operations system) is not defined in this document.
NOTE 2 The power converter sub-system case for use in electrical energy storage systems is currently covered by this document but will be covered by the IEC 63285 series (under preparation).
NOTE 3 Annex A provides examples of GCPCs. These examples contain GCPCs covered and not covered by this document.
This second edition includes the following significant technical changes with respect to the previous edition:
a) the title has been changed by adding the wording "and safety";
b) the scope has been changed in order to clarify the bi-directional grid-connected power converters (GCPCs) covered by this document.
- Standard44 pagesEnglish languagesale 15% off
- Standard44 pagesFrench languagesale 15% off
- Standard44 pagesEnglish and French languagesale 15% off
IEC 62909-1:2017 specifies general aspects of bi-directional grid-connected power converters (GCPC), consisting of a grid-side inverter with two or more types of DC-port interfaces on the application side with system voltages not exceeding 1 000 V AC or 1 500 V DC. In special cases, a GCPC will have only one DC-port interface, which is connected to a bidirectional energy-storage device. This document includes terminology, specifications, performance, safety, system architecture, and test-case definitions. The "system architecture" defines interaction between the inverter and converters. Requirements which are common, general, and independent of special characteristics of individual generators and bi-directional storages are defined.
This document does not cover uninterruptible power supply (UPS) systems, which fall under the scope of IEC 62040 (all parts). Requirements for internal and external digital communication might be necessary; the interface requirements including communication with distributed energy resources are provided in a future part of IEC 62909. All EMC requirements are defined by reference to existing IEC standards. External communication requirements are out of scope of this document.
- Standard91 pagesEnglish and French languagesale 15% off