IEC 60034-14:2018 specifies the factory acceptance vibration test procedures and vibration limits for certain electrical machines under specified conditions, when uncoupled from any load or prime mover. It is applicable to DC and three-phase AC machines, with shaft heights 56 mm and higher and a rated output up to 50 MW, at operational speeds from 120 min–1 up to and including 15 000 min–1. This new edition includes the following significant technical changes with respect to the previous edition:
- Improved explanation of the definition “free suspension”.
- Addition of an alternative method of rigid mount
- Definition of an improved option for shaft key.

  • Standard
    57 pages
    English language
    sale 15% off
  • Standard
    37 pages
    English and French language
    sale 15% off

Specifies the factory acceptance vibration test procedures and vibration limits for certain electrical machines under specified conditions, when uncoupled from any load or prime mover. Is applicable to d.c. and three-phase a.c. machines, with shaft heights 56 mm and higher and a rated output up to 50 MW, at operational speeds up to 15 000 per minute.

  • Standard
    29 pages
    English and French language
    sale 15% off
  • Standard
    29 pages
    English and French language
    sale 15% off

Gives guidance on the selection, installation and maintenance of electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. Note - IEC 61241-1-1 specifies requirements for the design, construction and testing of electrical apparatus. Apparatus within the scope of this standard may also be subject to additional requirements in other standards - for example IEC 60079-0.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    19 pages
    English language
    sale 15% off

Is applicable to electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. It specifies requirements for design, construction and testing of electrical apparatus. Note - IEC 61241-2 gives guidance on the selection, installation and maintenance of the apparatus. Apparatus within the scope of this standard may also be subject to additional requirements in other standards - for example, IEC 60079-0.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    34 pages
    English language
    sale 15% off