MT 2 - TC 95/MT 2
TC 95/MT 2
General Information
IEC 60255-26:2023 specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. It is applicable to measuring relays and protection equipment and combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This document specifies limits and test methods, for measuring relays and protection equipment in relation to electromagnetic emissions which might cause interference in other equipment. This document specifies the immunity test requirements for measuring relays and protection equipment in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.
- Standard116 pagesEnglish and French languagesale 15% off
IEC 60255-26:2013 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. This new edition includes the following significant technical changes with respect to the previous edition:
- definition of test specifications, test procedures and acceptance criteria per phenomena and port under test in one document;
- extension of radiated emission measurement for frequencies above 1 GHz;
- limitation of radiated emission measurement at 3 m distance for small equipment only;
- addition of zone A and zone B test level on surge test;
- extension of tests on the auxiliary power supply port by a.c. and d.c. voltage dips, a.c. component in d.c. (ripple) and gradual shut-down/start-up;
- harmonization of acceptance criteria for immunity tests.
- Standard92 pagesEnglish and French languagesale 15% off
IEC 60255-26:2008 is applicable to measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems; it specifies the essential requirements for electromagnetic compatibility for measuring relays and protection equipment intended to be used at industrial locations. The main difference of this new edition with respect to the previous one concerns the references to IEC 61000-4 and to CISPR 22.
- Standard28 pagesEnglish and French languagesale 15% off
IEC 60255-22-5:2008 specifies the general requirements for surge immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. Is based on IEC 61000-4-5. The objective of the tests is to confirm that the equipment under test will operate correctly when energized and subjected to high-energy disturbances on the power and interconnection lines, caused by surge voltages from switching and lightning effects. The main change in this new edition concerns line to earth tests.
- Standard40 pagesEnglish and French languagesale 15% off
IEC 60255-11:2008 specifies the general requirements for a.c. and d.c. power supplies, for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to dips, interruptions and alternating components (ripple). The main differences with respect to the previous edition are as follows: addition of voltage dips and interruptions test in a.c.; addition of gradual shut-down/start-up test; addition of reversal of d.c. power supply polarity test.
- Standard22 pagesEnglish and French languagesale 15% off
IEC 60255-22-4:2008 specifies the general requirements for electrical fast transient immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with these systems. Is based on IEC 61000-4-4. The objective of the tests is to confirm that the equipment under test will operate correctly when energized and subjected to repetitive fast transients (bursts) such as those originating from interrupting of inductive loads, relay contact bounce, etc. The main change with respect to the previous edition is the improvement of the test severity level regarding the repetition rate.
- Standard26 pagesEnglish and French languagesale 15% off
IEC 60255-22-2:2008 specifies the general requirements for electrostatic discharge tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. Is based on IEC 61000-4-2. The object of the tests is to confirm that the equipment being tested will not mal-operate when energized and subjected to an electrostatic discharge. The main changes with respect to the previous edition are the improvement of the test severity level, test set-up and test report.
- Standard25 pagesEnglish and French languagesale 15% off
Is applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. Lays down test severity levels, test equipment, test set-up, test procedure, criteria for acceptance, etc. This new edition is based on IEC 61000-4-18 and includes changes in the test equipment and test procedures.
- Standard25 pagesEnglish and French languagesale 15% off
Specifies the general requirements for radiated electromagnetic field immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The tests are intended to confirm that the equipment under test will operate correctly when energised and subjected to an electromagnetic field. The main change with respect to the previous edition concerns the extension of the frequency range.
- Standard24 pagesEnglish and French languagesale 15% off
Specifies general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to short duration, conducted, common and differential mode power frequency disturbances. Is based on IEC 61000-4-16.
- Standard21 pagesEnglish and French languagesale 15% off
Specifies the general requirements for conducted disturbances induced by electromagnetic fields for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems.
- Standard21 pagesEnglish and French languagesale 15% off
Specifies the general requirements for the measurement of radio-frequency emissions emanating from measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with such systems. Is based on CISPR 22.
- Standard25 pagesEnglish and French languagesale 15% off