IEC 61000-4-30:2025 defines the methods for measurement and interpretation of results for power quality parameters in AC power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method’s implementation. This document addresses measurement methods for in-situ measurements. This document covers two classes of measurement methods (Class A and Class S). The classes of measurement are specified in Clause 4.
NOTE 1 In this document, “A” stands for “advanced” and “S” stands for “surveys”.
Measurement of parameters covered by this document is limited to conducted phenomena in power systems. The power quality parameters considered in this document are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, rapid voltage changes, mains communicating system (MCS) voltages, magnitude of current, harmonic currents, interharmonic currents and current unbalance. Emissions in the 2 kHz to 150 kHz range are considered in Annex C and Annex D. Depending on the purpose of the measurement, all or a subset of the phenomena on this list can be measured.
NOTE 2 Test methods for verifying compliance with this document can be found in IEC 62586-2.
NOTE 3 The effects of transducers inserted between the power system and the instrument are acknowledged but not addressed in detail in this document. Guidance about effects of transducers can be found IEC TR 61869-103.
This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:
a) IEC 61000-4-30:2015/AMD1:2021 and IEC 61000-4-30:2015/COR1:2016 were included.
b) The measurement method for rapid voltage changes (RVC) has been corrected and extended.
c) The measurement method for voltage events has been updated and extended.
d) Annex C was divided into 2 parts:
1) Annex C: The measurement method from IEC 61000-4-7:2002 and IEC 61000‑4‑7:2002/AMD1:2008, Annex B for conducted emissions in the 2 kHz to 9 kHz range has been separate
2) Annex D: A new measurement method for conducted emissions in the 9 kHz to 150 kHz range has been added.
e) Annex D (underdeviation and overdeviation parameters) was removed.
f) Annex E (Class B) was removed.

  • Standard
    95 pages
    English language
    sale 15% off
  • Standard
    102 pages
    French language
    sale 15% off
  • Standard
    197 pages
    English and French language
    sale 15% off

IEC 61000-4-30:201 5 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method;s implementation. This standard addresses measurement methods for in-situ measurements. Measurement of parameters covered by this standard is limited to conducted phenomena in power systems. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, mains signalling on the supply voltage, rapid voltage changes, and current measurements. Emissions in the 2 kHz to 150 kHz range are considered in Annex C (informative), and over- and underdeviations are considered in Annex D (informative). Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the measurement method for current, previously informative, is now normative with some changes;
- the measurement method for RVC (rapid voltage change) has been added;
- the measurement method for conducted emissions in the 2 kHz to 150 kHz range has been added in informative Annex C;
- underdeviation and overdeviation parameters are moved to informative Annex D;
- Class A and Class S measurement methods are defined and clarified, while Class B is moved to informative Annex E and considered for future removal;
- measurement methods continue in this standard, but responsibility for influence quantities, performance, and test procedures are transferred to IEC 62586-2.
The contents of the corrigendum of December 2016 have been included in this copy.

  • Standard
    232 pages
    English language
    sale 15% off
  • Standard
    146 pages
    English and French language
    sale 15% off
  • Standard
    292 pages
    English and French language
    sale 15% off

IEC 61000-4-30:2008 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method's implementation. This standard addresses measurement methods for in situ measurements. Measurement of parameters covered by this standard is limited to voltage phenomena that can be conducted in a power system. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, mains signalling on the supply voltage and rapid voltage changes. Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. IEC 61000-4-30:2008 gives measurement methods and appropriate performance requirements, but does not set thresholds. The effects of transducers inserted between the power system and the instrument are acknowledged but not addressed in detail in this standard. Precautions on installing monitors on live circuits are addressed. IEC 61000-4-30:2008 has the status of a basic EMC publication in accordance with IEC Guide 107. This second edition cancels and replaces the first edition published in 2003. This edition includes the following significant technical changes with respect to the previous edition:
- Adjustments, clarifications, and corrections to class A and class B measurement methods.
- A new category, class S, intended for survey instruments, has been added.
- A new Annex C gives guidance on instruments.

  • Standard
    130 pages
    English and French language
    sale 15% off

Defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage and current harmonics and interharmonics, mains signalling on the supply voltage and rapid voltage changes. Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. This standard is a performance specification, not a design specification. The uncertainty tests in the ranges of influence quantities in this standard determine the performance requirements. This standard gives measurement methods but does not set thresholds. The contents of the corrigendum of August 2006 have been included in this copy.

  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    45 pages
    French language
    sale 15% off
  • Standard
    89 pages
    English and French language
    sale 15% off