This document describes the design, use and calibration of volumetric measures (capacity measures) which are intended for use in fixed locations in a laboratory or in the field. This document gives guidance on both standard and non-standard measures. It also covers portable and mobile measures. This document is applicable to the petroleum industry; however, it may be applied more widely to other applications. This document excludes measures for cryogenic liquids and pressurized measures as used for liquid petroleum gas (LPG) and liquefied natural gas (LNG). Volumetric measures are classified as test measures or prover tanks depending on capacity and design. Measures described in this document are primarily designed, calibrated and used to measure volumes from a measure which is wetted and drained for a specified time before use and designated to deliver. Many of the provisions, however, apply equally to measures which are used to measure a volume using a clean and dry measure and designated to contain. Guidance is given regarding commonly expected uncertainties and calibration specifications. The document also provides, in Annex A, reference formulae describing the properties of water and other fluids and materials used in volumetric measurement more generally.

  • Standard
    70 pages
    English language
    sale 15% off
  • Standard
    78 pages
    French language
    sale 15% off

ISO 2715:2017 describes and discusses the characteristics of turbine flowmeters. Attention is given to the factors to be considered in the application of turbine meters to liquid metering. These include the properties and nature of the liquid to be metered, the correct installation and operation of the meter, environmental effects, and the wide choice of secondary and ancillary equipment. Aspects of meter proving and maintenance are also discussed. ISO 2715:2017 is applicable to the metering of any appropriate liquid. Guidance is given on the use of turbine meters in the metering of two-component liquid mixtures such as water and oil. It is not applicable to two-phase flow when gases or solids are present under metering conditions (i.e. two-phase flow). It can be applied to the many and varied liquids encountered in industry for liquid metering and is not restricted to hydrocarbons. Guidance on the performance expected for fiscal/custody transfer applications for hydrocarbons is outlined. ISO 2715:2017 is not applicable to cryogenic liquids, such as liquefied natural gas (LNG) and refrigerated petroleum gas. It does not cover potable water applications.

  • Standard
    38 pages
    English language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off