This European standard specifies oxygen reduction systems that are used as fire prevention systems by creating an atmosphere in an area which is having a lower permanent oxygen concentration as in ambient conditions. The level of oxygen reduction is defined by the individual risks of these areas (see Annex A). Oxygen reduction is achieved by technical systems which are providing a flux of air containing a reduced concentration of oxygen.
This European standard specifies minimum requirements and...
view more

    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

This document specifies the assessment of Fire Containment and Control Systems (FCCS) and associated fire detection systems for railway vehicles as an alternative to the fire barriers specified in EN 45545-3.
This document describes:
- assessment of installation and capability of fire detection system;
- assessment of interaction between fire detection system and FCCS;
- application and limitations of assessment process (mock-up or real scale test).
This document considers any additional as...
view more

    • sale 10% off
    • Technical report
      24 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for compatibility and connectability assessment of the components of fire detection and alarm systems, fire protection systems and voice alarm systems. This document only includes system requirements when these are necessary for compatibility assessment. This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This document does not specify the manner in which the system is de...view more

    • sale 15% off
    • Standard
      26 pages
      English language
    • sale 15% off
    • Draft
      25 pages
      English language

This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1.
The operation and design categories defined in EN 45545-1 are used to establish hazard levels that are used as the basis of a classification system.
For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.
It is not within the scope of this European Standard to describe mea...
view more

    • sale 10% off
    • Standard
      49 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      48 pages
      English language
    • e-Library read for
      1 day

Data collection is of prime importance in fire safety, for several reasons: assessing the effect of any regulation, providing probability and gravity data to fire risk analysis, and the selection of scenarios for examples in fire safety engineering. Statistical data collection of fires is nevertheless collected and analysed from local or national perspectives at the time of publication of this document, making any comparison difficult. A first step identified in the need for harmonization is the...view more

    • sale 15% off
    • Technical specification
      15 pages
      English language
    • sale 15% off
    • Technical specification
      16 pages
      French language
    • sale 15% off
    • Draft
      15 pages
      English language

This document specifies performance requirements, methods of test and marking requirements for pressure reducing valves intended to reduce the downstream water pressure in the piping for water-based fire protection systems. Within the context of this document, pressure reducing valves include both pilot operated pressure reducing valves and direct acting pressure reducing valves. Performance and test requirements for other auxiliary components or attachments to pressure reducing valves are not w...view more

    • sale 15% off
    • Standard
      13 pages
      English language
    • sale 15% off
    • Draft
      13 pages
      English language

This document specifies requirements and gives recommendations for the design, installation, water supplies and backflow prevention, commissioning, maintenance and testing of fixed residential fire sprinkler systems in buildings for residential occupancies.
This document is intended for use by those concerned with purchasing, designing, installing, testing, inspecting, approving, operating and maintaining automatic residential sprinkler systems, in order that such equipment will function as int...
view more

    • sale 10% off
    • Corrigendum
      2 pages
      English language
    • e-Library read for
      1 day

This document defines performance requirements, methods of testing and marking requirements for fire pump relief valves intended to rapidly relieve the excessive water pressure in the supply piping for standpipe systems or sprinkler systems or both. Performance and test requirements for other auxiliary components or attachments to fire pump relief valves are not covered by this standard.

    • sale 15% off
    • Standard
      11 pages
      English language
    • sale 15% off
    • Standard
      11 pages
      English language

This document specifies performance requirements, test methods and marking requirements for pendent early suppression fast response (ESFR) sprinklers. NOTE This document currently provides requirements for K202 and K242 ESFR pendent sprinklers.

    • sale 15% off
    • Standard
      46 pages
      English language

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

This document specifies performance, requirements, test methods and marking requirements, for check valves used to supply water in automatic fire protection systems. It is not applicable to trim valves.

    • sale 15% off
    • Standard
      12 pages
      English language

This document specifies the requirements, test methods and performance criteria for audible alarm devices intended to signal an audible warning, with or without voice messages between a fire detection and fire alarm system and the occupants of a building. This document specifies fire alarm audible alarm devices for two types of application environment, type A for indoor use and type B for outdoor use. This document is not applicable to: a) loudspeaker-type devices primarily intended for emitting...view more

    • sale 15% off
    • Standard
      38 pages
      English language

This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...
view more

    • sale 10% off
    • Standard
      74 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat, for use only in automatic sprinkler systems for domestic and residential applications as defined in EN 16925:− .
This standard does not cover representative fire and other tests for special sprinklers that are intended to provide for speci...
view more

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      62 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements, test methods and performance criteria for transmission path isolators for use in fire detection and fire alarm systems for buildings (for general requirements and definitions, see ISO 7240‑1). Means of isolation or protection incorporated within control and indicating equipment are not covered by this document.

    • sale 15% off
    • Standard
      30 pages
      English language

This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat, for use only in automatic sprinkler systems for domestic and residential applications as defined in EN 16925:− .
This standard does not cover representative fire and other tests for special sprinklers that are intended to provide for speci...
view more

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      62 pages
      English language
    • e-Library read for
      1 day

This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes not exceeding 260 m³.

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      17 pages
      English language
    • e-Library read for
      1 day

This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes exceeding 260 m³.

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system. The components comply either with the requirements of EN 54 or with a manufacturer’s specification where there is no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment.
This document covers transmission path onl...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plants, and particular requirements for sprinkler systems that are integral to measures for the protection of life.
This European Standard covers only the types of sprinkler specified in EN 12259 1 (see Annex L).
The requirements and recommendations of this European Standard are also applicable to any addition, extensio...
view more

    • sale 10% off
    • Standard
      215 pages
      English language
    • e-Library read for
      1 day