This document specifies requirements for gaseous fire-extinguishing systems, with respect to FK 5 1 12 extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This document covers only systems operating at nominal pressures of 25 bar, 34,5 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft14 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of EN 15004 contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 23 extinguishant. It includes details of physical properties, specification, usage and safety aspects and is applicable to systems operating at a nominal pressure of 41 bar without nitrogen superpressurization and 70 bar superpressurized with nitrogen.
- Standard14 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft12 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of EN 15004 contains specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 227ea extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This part of EN 15004 covers systems operating at nominal pressures of 25 bar, 42 bar and 50 bar with nitrogen propellant. This does not preclude the use of other systems.
- Standard14 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft13 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements for gaseous fire-extinguishing systems, with respect to the HFC 125 extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This document is apploicable for systems operating at nominal pressures of 25 bar and 42 bar, superpressurized with nitrogen. This does not preclude the use of other systems.
- Standard13 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft10 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies minimum performance requirements for protective clothing designed to be worn during firefighting activities. The requirements are detailed in this document covering heat and flame, mechanical, chemical, comfort, visibility, etc.
This document covers the general clothing design, the minimum performance levels of the material used, the methods of test to be used to determine these performance levels, marking and information supplied by the manufacturer.
This document make...view more
- Standard44 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft40 pagesEnglish language
sale 10% off- e-Library read for1 day
This European standard specifies oxygen reduction systems that are used as fire prevention systems by creating an atmosphere in an area which is having a lower permanent oxygen concentration as in ambient conditions. The level of oxygen reduction is defined by the individual risks of these areas (see Annex A). Oxygen reduction is achieved by technical systems which are providing a flux of air containing a reduced concentration of oxygen.
This European standard specifies minimum requirements and...view more
- Standard37 pagesEnglish language
sale 10% off- e-Library read for1 day
1.1 This document defines requirements and tests which apply to:
- collecting heads with a nominal pressure of 16 bar (1,6 MPa) PN16 which are used by fire and rescue services to combine two or more inlets into one or more outlets;
- dividing breechings with a nominal pressure of 16 bar (1,6 MPa) PN 16 which are used by fire and rescue services to divide one or more inlets into two or more outlets.
NOTE 1 In this document "ColDiv" is used to refer both to collecting heads and dividing breechi...view more
- Standard25 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft25 pagesEnglish language
sale 10% off- e-Library read for1 day
1.1 This document specifies the additional or deviating requirements to prEN 81 20:2018 for new passenger and goods passenger lifts, which may be used for firefighting and evacuation purposes under firefighters control.
1.2 This document applies, when the following conditions are fulfilled:
- the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas;
- the building design limits the flow of water into ...view more
- Standard46 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft51 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the minimum performance requirements and methods of test for firehoods that cover the head and neck and are used for wildland firefighting. An optional requirement has been included to provide limited protection against particulate contaminants This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. This document doe...view more
- Standard16 pagesEnglish language
sale 15% off- Draft16 pagesEnglish language
sale 15% off
This International Standard specifies methods of test and minimum performance requirements for protective clothing to
be worn in wildland firefighting and associated activities. This clothing is not intended to provide protection during fire
entrapment. This International Standard applies to the general design of the garment, the minimum level of performance for the materials employed and the methods of test to determine these levels.
This International Standard is not applicable to clothing for...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
This draft European Standard specifies the characteristics, performance and test methods for extinguishing aerosol dispensers, in accordance with Directive 75/324/EEC, for fire extinguishing purposes. Requirements in this draft Standard are specified for products containing less than 1 kg or 1 l of extinguishing media, which can be expelled by the action of internal pressure and are intended to extinguish test fires of type A + B, or type A + F, or type A + B + F classes of EN 2. These extinguis...view more
- Standard41 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft41 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard2 pagesEnglish language
sale 15% off
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...view more
- Standard74 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding te...view more
- Standard74 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat, for use only in automatic sprinkler systems for domestic and residential applications as defined in EN 16925:− .
This standard does not cover representative fire and other tests for special sprinklers that are intended to provide for speci...view more
- Standard64 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft62 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes exceeding 260 m³.
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft18 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies fire testing requirements for water mist systems used for fire protection of machinery in enclosures with volumes not exceeding 260 m³.
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft17 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plants, and particular requirements for sprinkler systems that are integral to measures for the protection of life.
This European Standard covers only the types of sprinkler specified in EN 12259 1 (see Annex L).
The requirements and recommendations of this European Standard are also applicable to any addition, extensio...view more
- Standard215 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the Sweating Torso as a method to
measure the coupled heat and mass transfer through protective clothing
in fire fighters’ specific conditions.
NOTE The Sweating Torso is developed to perform highly reproducible
laboratory tests for heat and mass transfer on clothing systems under
controlled conditions which are closely correlated to real conditions. The
Sweating Torso is a cylinder with the same size as a human trunk. The
layers of the measurement cylinder are ...view more
- Amendment8 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the minimum performance requirements and methods of test for helmets used for wildland firefighting. This document covers the general design of wildland firefighting helmets, the minimum levels of performance for the materials employed and the methods of test used. The personal protection equipment (PPE) is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemica...view more
- Standard22 pagesEnglish language