Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is inserted into and then expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe.
Note 1—An ASTM specification for the installation of folded PVC pipe is under preparation and will be referenced in this specification when published.
1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
1.5 The following precautionary statement pertains to the test method portion only, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Aug-1997
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1504-97e1 - Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
An American National Standard
e1
Designation: F 1504 – 97
Standard Specification for
Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer
1
and Conduit Rehabilitation
This standard is issued under the fixed designation F 1504; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Sections 6.1 and 15.2.3 and Tables 3 and 4 were editorially updated in July 2002.
1. Scope D 1600 Terminology for Abbreviated Terms Relating to
2
Plastics
1.1 This specification covers requirements and test methods
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
for materials, dimensions, workmanship, flattening resistance,
Compounds and Chlorinated Poly(Vinyl Chloride)
impact resistance, pipe stiffness, extrusion quality, and a form
2
(CPVC) Compounds
of marking for folded (vinyl chloride) (PVC) pipe for existing
D 2122 Test Method of Determining Dimensions of Ther-
sewer and conduit rehabilitation.
3
moplastic Pipe and Fittings
1.2 Pipe produced to this specification is for use in non-
D 2152 Test Method for Adequacy of Fusion of Extruded
pressure sewer and conduit rehabilitation where the folded
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
PVC pipe is inserted into and then expanded to conform to the
3
Acetone Immersion
wall of the original conduit forming a new structural pipe-
D 2412 Test Method of Determination of External Loading
within-a-pipe.
3
Characteristics of Plastic Pipe by Parallel-Plate Loading
NOTE 1—An ASTM specification for the installation of folded PVC
D 2444 Test Method for Determination of Impact Resis-
pipe is under preparation and will be referenced in this specification when
tance of Thermoplastic Pipe and Fittings by Means of a
published.
3
Tup (Falling Weight)
3
1.3 This specification includes pipe made only from mate-
F 412 Terminology Relating to Plastic Piping Systems
rials specified in Section 6. This specification does not include
F 1057 Practice for Estimating the Quality of Extruded
pipe manufactured from reprocessed, recycled, or reclaimed
Poly(Vinyl Chloride) (PVC) Pipe by the Heat Reversion
3
PVC.
Technique
1.4 The values stated in inch-pound units are to be regarded
2.2 Federal Standard:
4
as the standard. The SI units given in parentheses are provided
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
for information only.
2.3 Military Standard:
4
1.5 The following precautionary statement pertains to the
MIL-STD-129 Marking for Shipment and Storage
test method portion only, Section 11, of this specification: This
standard does not purport to address all of the safety concerns, 3. Terminology
if any, associated with its use. It is the responsibility of the user
3.1 General—Abbreviations used in this specification are in
of this standard to establish appropriate safety and health
accordance with Terminology D 1600 and definitions are in
practices and determine the applicability of regulatory limita-
accordance with Terminology F 412 unless otherwise indi-
tions prior to use.
cated.
3.2 Definitions of Terms Specific to This Standard:
2. Referenced Documents
3.2.1 folded pipe—pipe that has been manufactured in a
2.1 ASTM Standards:
folded shape for use in existing sewer and conduit rehabilita-
2
D 618 Practice for Conditioning Plastics for Testing
tion. See Fig. 1.
D 790 Test Methods for Flexural Properties of Unreinforced
3.2.2 rounded pipe—A rounded pipe is a sample for test
and Reinforced Plastics and Electrical Insulating Materi-
purposes formed when the folded pipe has been inserted into a
2
als
circular casing pipe and expanded with heat and pressure to fit
tightly to the casing pipe taking a circular cross section, in
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic
accordance with Section 10. See Fig. 1.
Piping Systems and is the direct responsibility of Subcommittee F17.67 on
Trenchless Plastic Pipeline Technology.
3
Current edition approved Aug. 10, 1996. Published November 1997. Originally Annual Book of ASTM Standards, Vol 08.04.
4
published as F 1504 – 94. Last previous edition F 1504 – 96. Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
2
Annual Book of ASTM Standards, Vol 08.01. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 1504
material meets t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.