Standard Test Method for Bond Strength of Epoxy-Resin Systems Used With Concrete By Slant Shear

ABSTRACT
This test method covers the determination of the bond strength of epoxy-resin-base bonding systems for use with Portland-cement concrete. The test method covers bonding hardened concrete to hardened or freshly-mixed concrete. The bond strength is determined by using the epoxy system to bond together two equal sections of Portland-cement mortar cylinder. After suitable curing of the bonding agent, the test is performed by determining the compressive strength of the composite cylinder. Apparatus to mix Portland-cement mortar shall be as described, except for the sections on specimen molds, tamper, and testing machine. The molds shall be constructed in the form of right cylinders. A dummy section shall be machined of a hard material that is not attacked by Portland-cement mortar. The testing machine shall be as described. Laboratory conditions, materials, proportions, and procedures for mixing the Portland-cement mortar shall be tested to meet the requirements specified.
SIGNIFICANCE AND USE
5.1 The strength developed by a bonding system that joins two regions of concrete is its most important property.
SCOPE
1.1 This test method covers the determination of the bond strength of epoxy-resin-base bonding systems for use with portland-cement concrete. This test method covers bonding hardened concrete to hardened or freshly-mixed concrete.  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific hazard statement is given in Section 8. (Warning —Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to exposed skin and tissue upon prolonged exposure.2)

General Information

Status
Historical
Publication Date
14-Jun-2013
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C882/C882M-13 - Standard Test Method for Bond Strength of Epoxy-Resin Systems Used With Concrete By Slant Shear
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C882/C882M-13 - Standard Test Method for Bond Strength of Epoxy-Resin Systems Used With Concrete By Slant Shear
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C882/C882M − 13
StandardTest Method for
Bond Strength of Epoxy-Resin Systems Used With Concrete
1
By Slant Shear
This standard is issued under the fixed designation C882/C882M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C192/C192MPractice for Making and Curing ConcreteTest
Specimens in the Laboratory
1.1 This test method covers the determination of the bond
C470/C470MSpecification for Molds for Forming Concrete
strength of epoxy-resin-base bonding systems for use with
Test Cylinders Vertically
portland-cement concrete. This test method covers bonding
C511Specification for Mixing Rooms, Moist Cabinets,
hardened concrete to hardened or freshly-mixed concrete.
Moist Rooms, and Water Storage Tanks Used in the
1.2 The values stated in either SI units or inch-pound units
Testing of Hydraulic Cements and Concretes
are to be regarded separately as standard. The values stated in
C617Practice for Capping Cylindrical Concrete Specimens
each system may not be exact equivalents; therefore, each
C881/C881MSpecification for Epoxy-Resin-Base Bonding
system shall be used independently of the other. Combining
Systems for Concrete
values from the two systems may result in non-conformance
with the standard.
3. Terminology
1.3 This standard does not purport to address all of the
3.1 Definitions:
safety concerns, if any, associated with its use. It is the
3.1.1 Fordefinitionsoftermsusedinthisspecification,refer
responsibility of the user of this standard to establish appro-
to Terminology C125.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. A specific hazard 3.2 Definitions of Terms Specific to This Standard:
statement is given in Section 8.(Warning —Fresh hydraulic 3.2.1 bonding system, n—the product resulting from the
cementitious mixtures are caustic and may cause chemical
combination of all the components supplied for use as a
2
burns to exposed skin and tissue upon prolonged exposure. ) bonding material.
3.2.2 component, n—a constituent that is intended to be
2. Referenced Documents
combined with one or more other constituents to form a
3
2.1 ASTM Standards:
bonding system.
C39/C39MTest Method for Compressive Strength of Cylin-
3.2.3 contact strength, n—bond strength measured by slant
drical Concrete Specimens
shear after a specified contact and cure time.
C109/C109MTest Method for Compressive Strength of
3.2.4 contact time, n—specified time between when the
Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
bonding system is applied and when the two segments are
Specimens)
bonded together and still achieve a specified bond strength
C125Terminology Relating to Concrete and Concrete Ag-
after a specified curing time and temperature.
gregates
C150Specification for Portland Cement
3.2.5 formulator, n—the agency responsible for preparing
the separate components and for recommending the propor-
tions to be used in preparing the final bonding system.
1
This test method is under the jurisdiction of ASTM Committee C09 on
Concrete and ConcreteAggregatesand is the direct responsibility of Subcommittee
4. Summary of Test Method
C09.25 on Organic Materials for Bonding.
Current edition approved June 15, 2013. Published August 2013. Originally
4.1 The bond strength is determined by using the epoxy
approved in 1978. Last previous edition approved in 2012 as C882/C882M–12.
system to bond together two equal sections of a 75 by 150-mm
DOI: 10.1520/C0882_C0882M-13.
2
[3 by 6-in.] portland-cement mortar cylinder, each section of
See Section on Safety Precautions, Manual ofAggregate and ConcreteTesting,
Annual Book of ASTM Standards, Vol. 04.02.
which has a diagonally cast bonding area at a 30° angle from
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
vertical. After suitable curing of the bonding agent, the test is
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
performed by determining the compressive strength of the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. composite cylinder.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C882/C882M − 13
5. Significance and Use 7. Materials
7.1 Portland Cement Mortar Specimens Laboratory
5.1 The strength developed by a bonding system that joins
two regions of concrete is its most important property. conditions, materials, prop
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C882/C882M − 12 C882/C882M − 13
Standard Test Method for
Bond Strength of Epoxy-Resin Systems Used With Concrete
1
By Slant Shear
This standard is issued under the fixed designation C882/C882M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope Scope*
1.1 This test method covers the determination of the bond strength of epoxy-resin-base bonding systems for use with
portland-cement concrete. This test method covers bonding hardened concrete to hardened or freshly-mixed concrete.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. A specific hazard statement is given in Section 8.(Warning —Fresh hydraulic cementitious mixtures are
2
caustic and may cause chemical burns to exposed skin and tissue upon prolonged exposure. )
2. Referenced Documents
3
2.1 ASTM Standards:
C39/C39M Test Method for Compressive Strength of Cylindrical Concrete Specimens
C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
C125 Terminology Relating to Concrete and Concrete Aggregates
C150 Specification for Portland Cement
C192/C192M Practice for Making and Curing Concrete Test Specimens in the Laboratory
C470/C470M Specification for Molds for Forming Concrete Test Cylinders Vertically
C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic
Cements and Concretes
C617 Practice for Capping Cylindrical Concrete Specimens
C881/C881M Specification for Epoxy-Resin-Base Bonding Systems for Concrete
3. Terminology
3.1 Definitions:
3.1.1 For definitions of terms used in this specification, refer to Terminology C125.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 bonding system, n—the product resulting from the combination of all the components supplied for use as a bonding
material.
3.2.2 component, n—a constituent that is intended to be combined with one or more other constituents to form a bonding system.
3.2.3 contact strength, n—bond strength measured by slant shear after a specified contact and cure time.
1
This test method is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee C09.25 on
Organic Materials for Bonding.
Current edition approved May 1, 2012June 15, 2013. Published June 2012August 2013. Originally approved in 1978. Last previous edition approved in 20052012 as
ε1
C882/C882M–05–12. . DOI: 10.1520/C0882_C0882M-12.10.1520/C0882_C0882M-13.
2
See Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol. 04.02.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C882/C882M − 13
3.2.4 contact time, n—specified time between when the bonding system is applied and when the two segments are bonded
together and still achieve a specified bond strength after a specified curing time and temperature.
3.2.5 formulator, n—the agency responsible for preparing the separate components and for recommending the proportions to be
used in preparing the final bonding system.
4. Summary of Test Method
4.1 The bond strength is determined by using the epoxy system to bond together two equal sections of a 75 by 150-mm [3 by
6-in.] portland-cement mortar cy
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.