Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils

SIGNIFICANCE AND USE
This test method provides a disturbed soil sample for moisture content determination, for identification and classification (Practices D 2487 and D 2488) purposes, and for laboratory tests appropriate for soil obtained from a sampler that will produce large shear strain disturbance in the sample such as Test Methods D 854, D 2216, and D 6913. Soil deposits containing gravels, cobbles, or boulders typically result in penetration refusal and damage to the equipment.
This test method provides a disturbed soil sample for moisture content determination and laboratory identification. Sample quality is generally not suitable for advanced laboratory testing for engineering properties. The process of driving the sampler will cause disturbance of the soil and change the engineering properties. Use of the thin wall tube sampler (Practice D 1587) may result in less disturbance in soft soils. Coring techniques may result in less disturbance than SPT sampling for harder soils, but it is not always the case, that is, some cemented soils may become loosened by water action during coring; see Practice D 6151, and Guide D 6169.
This test method is used extensively in a great variety of geotechnical exploration projects. Many local correlations and widely published correlations which relate blow count, or N-value, and the engineering behavior of earthworks and foundations are available. For evaluating the liquefaction potential of sands during an earthquake event, the N-value should be normalized to a standard overburden stress level. Practice D 6066 provides methods to obtain a record of normalized resistance of sands to the penetration of a standard sampler driven by a standard energy. The penetration resistance is adjusted to drill rod energy ratio of 60 % by using a hammer system with either an estimated energy delivery or directly measuring drill rod stress wave energy using Test Method D 4633.
Note 1—The reliability of data and interpretations generated by this practice i...
SCOPE
1.1 This test method describes the procedure, generally known as the Standard Penetration Test (SPT), for driving a split-barrel sampler to obtain a representative disturbed soil sample for identification purposes, and measure the resistance of the soil to penetration of the sampler. Another method (Test Method D 3550) to drive a split-barrel sampler to obtain a representative soil sample is available but the hammer energy is not standardized.
1.2 Practice D 6066 gives a guide to determining the normalized penetration resistance of sands for energy adjustments of N-value to a constant energy level for evaluating liquefaction potential.
1.3 Test results and identification information are used to estimate subsurface conditions for foundation design.
1.4 Penetration resistance testing is typically performed at 5-foot depth intervals or when a significant change of materials is observed during drilling, unless otherwise specified.
1.5 This test method is limited to use in nonlithified soils and soils whose maximum particle size is approximately less than one-half of the sampler diameter.
1.6 This test method involves use of rotary drilling equipment (Guide D 5783, Practice D 6151). Other drilling and sampling procedures (Guide D 6286, Guide D 6169) are available and may be more appropriate. Considerations for hand driving or shallow sampling without boreholes are not addressed. Subsurface investigations should be recorded in accordance with Practice D 5434. Samples should be preserved and transported in accordance with Practice D 4220 using Group B. Soil samples should be identified by group name and symbol in accordance with Practice D 2488.
1.7 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026, unless superseded by this test method.
1.8 The values stated in inch-pound units are to be regarded as standard, except as noted below...

General Information

Status
Historical
Publication Date
30-Sep-2008
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D1586-08a - Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D1586-08a - Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D1586-08a - Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D1586 – 08a
Standard Test Method for
Standard Penetration Test (SPT) and Split-Barrel Sampling
1
of Soils
This standard is issued under the fixed designation D1586; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* 1.8 Thevaluesstatedininch-poundunitsaretoberegarded
as standard, except as noted below. The values given in
1.1 This test method describes the procedure, generally
parentheses are mathematical conversions to SI units, which
known as the Standard Penetration Test (SPT), for driving a
are provided for information only and are not considered
split-barrel sampler to obtain a representative disturbed soil
standard.
sample for identification purposes, and measure the resistance
1.8.1 The gravitational system of inch-pound units is used
of the soil to penetration of the sampler.Another method (Test
when dealing with inch-pound units. In this system, the pound
Method D3550) to drive a split-barrel sampler to obtain a
(lbf)representsaunitofforce(weight),whiletheunitformass
representative soil sample is available but the hammer energy
is slugs.
is not standardized.
1.9 Penetration resistance measurements often will involve
1.2 Practice D6066 gives a guide to determining the nor-
safety planning, administration, and documentation. This test
malized penetration resistance of sands for energy adjustments
method does not purport to address all aspects of exploration
of N-value to a constant energy level for evaluating liquefac-
andsitesafety. This standard does not purport to address all of
tion potential.
the safety concerns, if any, associated with its use. It is the
1.3 Test results and identification information are used to
responsibility of the user of this standard to establish appro-
estimate subsurface conditions for foundation design.
priate safety and health practices and determine the applica-
1.4 Penetration resistance testing is typically performed at
bility of regulatory limitations prior to use.Performanceofthe
5-footdepthintervalsorwhenasignificantchangeofmaterials
test usually involves use of a drill rig; therefore, safety
is observed during drilling, unless otherwise specified.
requirements as outlined in applicable safety standards (for
1.5 This test method is limited to use in nonlithified soils
2 3
example, OSHA regulations, NDA Drilling Safety Guide,
and soils whose maximum particle size is approximately less
drilling safety manuals, and other applicable state and local
than one-half of the sampler diameter.
regulations) must be observed.
1.6 This test method involves use of rotary drilling equip-
ment (Guide D5783, Practice D6151). Other drilling and
2. Referenced Documents
sampling procedures (Guide D6286, Guide D6169) are avail-
4
2.1 ASTM Standards:
able and may be more appropriate. Considerations for hand
D653 Terminology Relating to Soil, Rock, and Contained
driving or shallow sampling without boreholes are not ad-
Fluids
dressed. Subsurface investigations should be recorded in ac-
D854 Test Methods for Specific Gravity of Soil Solids by
cordance with Practice D5434. Samples should be preserved
Water Pycnometer
and transported in accordance with Practice D4220 using
D1587 PracticeforThin-WalledTubeSamplingofSoilsfor
GroupB.Soilsamplesshouldbeidentifiedbygroupnameand
Geotechnical Purposes
symbol in accordance with Practice D2488.
D2216 Test Methods for Laboratory Determination of Wa-
1.7 All observed and calculated values shall conform to the
ter (Moisture) Content of Soil and Rock by Mass
guidelines for significant digits and rounding established in
Practice D6026, unless superseded by this test method.
2
Available from Occupational Safety and Health Administration (OSHA), 200
Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.
1 3
This method is under the jurisdiction of ASTM Committee D18 on Soil and Available from the National Drilling Association, 3511 Center Rd., Suite 8,
Rock and is the direct responsibility of Subcommittee D18.02 on Sampling and Brunswick, OH 44212, http://www.nda4u.com.
4
Related Field Testing for Soil Evaluations. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Oct. 1, 2008. Published October 2008. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1958. Last previous edition approved in 2008 as D1586–08. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/D1586-08A. the ASTM website.
*A Summary of Changes sect
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately,ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D1586–08 Designation: D 1586 – 08a
Standard Test Method for
Standard Penetration Test (SPT) and Split-Barrel Sampling
1
of Soils
This standard is issued under the fixed designation D1586; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 Thistestmethoddescribestheprocedure,generallyknownastheStandardPenetrationTest(SPT),fordrivingasplit-barrel
sampler to obtain a representative disturbed soil sample for identification purposes, and measure the resistance of the soil to
penetration of the sampler. Another method (Test Method D3550) to drive a split-barrel sampler to obtain a representative soil
sample is available but the hammer energy is not standardized.
1.2 Practice D6066 gives a guide to determining the normalized penetration resistance of sands for energy adjustments of
N-value to a constant energy level for evaluating liquefaction potential.
1.3 Test results and identification information are used to estimate subsurface conditions for foundation design.
1.4 Penetration resistance testing is typically performed at 5-foot depth intervals or when a significant change of materials is
observed during drilling, unless otherwise specified.
1.5 This test method is limited to use in nonlithified soils and soils whose maximum particle size is approximately less than
one-half of the sampler diameter.
1.6 This test method involves use of rotary drilling equipment (Guide D5783, Practice D6151). Other drilling and sampling
procedures(GuideD6286,GuideD6169)areavailableandmaybemoreappropriate.Considerationsforhanddrivingorshallow
sampling without boreholes are not addressed. Subsurface investigations should be recorded in accordance with Practice D5434.
SamplesshouldbepreservedandtransportedinaccordancewithPracticeD4220usingGroupB.Soilsamplesshouldbeidentified
by group name and symbol in accordance with Practice D2488.
1.7 AllobservedandcalculatedvaluesshallconformtotheguidelinesforsignificantdigitsandroundingestablishedinPractice
D6026, unless superseded by this test method.
1.8 Thevaluesstatedininch-poundunitsaretoberegardedasstandard,exceptasnotedbelow.Thevaluesgiveninparentheses
are mathematical conversions to SI units, which are provided for information only and are not considered standard.
1.8.1 The gravitational system of inch-pound units is used when dealing with inch-pound units. In this system, the pound (lbf)
represents a unit of force (weight), while the unit for mass is slugs.
1.9 Penetration resistance measurements often will involve safety planning, administration, and documentation. This test
method does not purport to address all aspects of exploration and site safety. This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety
and health practices and determine the applicability of regulatory limitations prior to use.Performanceofthetestusuallyinvolves
2
use of a drill rig; therefore, safety requirements as outlined in applicable safety standards (for example, OSHAregulations, NDA
3
Drilling Safety Guide, drilling safety manuals, and other applicable state and local regulations) must be observed.
2. Referenced Documents
4
2.1 ASTM Standards:
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D854 Test Methods for Specific Gravity of Soil Solids by Water Pycnometer
D1587 Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes
1
ThismethodisunderthejurisdictionofASTMCommitteeD18onSoilandRockandisthedirectresponsibilityofSubcommitteeD18.02onSamplingandRelatedField
Testing for Soil Evaluations.
Current edition approved Feb.Oct. 1, 2008. Published MarchOctober 2008. Originally approved in 1958. Last previous edition approved in 19992008 as
D1586–99.D1586–08.
2
Available from Occupational Safety and Health Administration (OSHA), 200 Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.
3
Available from the National Drilling Association, 3511 Center Rd., Suite 8, Brunswick, OH 44212, http://www.nda4u.com.
4
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, re
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately,ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D1586–08 Designation: D 1586 – 08a
Standard Test Method for
Standard Penetration Test (SPT) and Split-Barrel Sampling
1
of Soils
This standard is issued under the fixed designation D1586; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 Thistestmethoddescribestheprocedure,generallyknownastheStandardPenetrationTest(SPT),fordrivingasplit-barrel
sampler to obtain a representative disturbed soil sample for identification purposes, and measure the resistance of the soil to
penetration of the sampler. Another method (Test Method D3550) to drive a split-barrel sampler to obtain a representative soil
sample is available but the hammer energy is not standardized.
1.2 Practice D6066 gives a guide to determining the normalized penetration resistance of sands for energy adjustments of
N-value to a constant energy level for evaluating liquefaction potential.
1.3 Test results and identification information are used to estimate subsurface conditions for foundation design.
1.4 Penetration resistance testing is typically performed at 5-foot depth intervals or when a significant change of materials is
observed during drilling, unless otherwise specified.
1.5 This test method is limited to use in nonlithified soils and soils whose maximum particle size is approximately less than
one-half of the sampler diameter.
1.6 This test method involves use of rotary drilling equipment (Guide D5783, Practice D6151). Other drilling and sampling
procedures(GuideD6286,GuideD6169)areavailableandmaybemoreappropriate.Considerationsforhanddrivingorshallow
sampling without boreholes are not addressed. Subsurface investigations should be recorded in accordance with Practice D5434.
SamplesshouldbepreservedandtransportedinaccordancewithPracticeD4220usingGroupB.Soilsamplesshouldbeidentified
by group name and symbol in accordance with Practice D2488.
1.7 AllobservedandcalculatedvaluesshallconformtotheguidelinesforsignificantdigitsandroundingestablishedinPractice
D6026, unless superseded by this test method.
1.8 Thevaluesstatedininch-poundunitsaretoberegardedasstandard,exceptasnotedbelow.Thevaluesgiveninparentheses
are mathematical conversions to SI units, which are provided for information only and are not considered standard.
1.8.1 The gravitational system of inch-pound units is used when dealing with inch-pound units. In this system, the pound (lbf)
represents a unit of force (weight), while the unit for mass is slugs.
1.9 Penetration resistance measurements often will involve safety planning, administration, and documentation. This test
method does not purport to address all aspects of exploration and site safety. This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety
and health practices and determine the applicability of regulatory limitations prior to use.Performanceofthetestusuallyinvolves
2
use of a drill rig; therefore, safety requirements as outlined in applicable safety standards (for example, OSHAregulations, NDA
3
Drilling Safety Guide, drilling safety manuals, and other applicable state and local regulations) must be observed.
2. Referenced Documents
4
2.1 ASTM Standards:
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D854 Test Methods for Specific Gravity of Soil Solids by Water Pycnometer
D1587 Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes
1
ThismethodisunderthejurisdictionofASTMCommitteeD18onSoilandRockandisthedirectresponsibilityofSubcommitteeD18.02onSamplingandRelatedField
Testing for Soil Evaluations.
Current edition approved Feb.Oct. 1, 2008. Published MarchOctober 2008. Originally approved in 1958. Last previous edition approved in 19992008 as
D1586–99.D1586–08.
2
Available from Occupational Safety and Health Administration (OSHA), 200 Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.
3
Available from the National Drilling Association, 3511 Center Rd., Suite 8, Brunswick, OH 44212, http://www.nda4u.com.
4
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, re
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.