ASTM C1329-03a
(Specification)Standard Specification for Mortar Cement
Standard Specification for Mortar Cement
SCOPE
1.1 This specification covers three types of mortar cement for use where mortar for masonry is required.
1.2 The values stated in SI units are to be regarded as the standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10, of measurements made in other units.
1.3 The text of this standard refers to notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 The following safety hazards caveat pertains only to Annex A1. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 1329 – 03a
Standard Specification for
1
Mortar Cement
This standard is issued under the fixed designation C 1329; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 185 Test Method for Air Content of Hydraulic Cement
3
Mortar
1.1 This specification covers three types of mortar cement
C 187 Test Method for Normal Consistency of Hydraulic
for use where mortar for masonry is required.
3
Cement
1.2 The values stated in SI units are to be regarded as the
3
C 188 Test Method for Density of Hydraulic Cement
standard. Values in SI units shall be obtained by measurement
3
C 219 Terminology Relating to Hydraulic Cement
in SI units or by appropriate conversion, using the Rules for
C 230/C 230M Specification for Flow Table for Use in Tests
Conversion and Rounding given in IEEE/ASTM SI 10, of
3
of Hydraulic Cement
measurements made in other units.
C 266 Test Method for Time of Setting of Hydraulic-
1.3 The text of this standard refers to notes and footnotes
3
Cement Paste by Gillmore Needles
which provide explanatory material. These notes and footnotes
C 305 Practice for Mechanical Mixing of Hydraulic Cement
(excluding those in tables and figures) shall not be considered
3
Pastes and Mortars of Plastic Consistency
as requirements of the standard.
C 430 Test Method for Fineness of Hydraulic Cement by
1.4 The following safety hazards caveat pertains only to
3
the 45-μm (No. 325) Sieve
Annex A1. This standard does not purport to address all of the
C 511 Specification for Moist Cabinets, Moist Rooms, and
safety concerns, if any, associated with its use. It is the
Water Storage Tanks Used in the Testing of Hydraulic
responsibility of the user of this standard to establish appro-
3
Cements and Concretes
priate safety and health practices and determine the applica-
3
C 778 Specification for Standard Sand
bility of regulatory limitations prior to use. (Warning—Fresh
C 780 Test Method for Preconstruction and Construction
hydraulic cementitious mixtures are caustic and may cause
2
Evaluation of Mortars for Plain and Reinforced Unit
chemical burns to skin and tissue upon prolonged exposure. )
5
Masonry
2. Referenced Documents C 1072 Test Method for Measurement of Masonry Flexural
5
Bond Strength
2.1 ASTM Standards:
3
C 1506 Test Method for Water Retention of Hydraulic
C 91 Specification for Masonry Cement
3
Cement-Based Mortars and Plasters
C 109/C 109M Test Method for Compressive Strength of
IEEE/ASTM SI 10 Standard for Use of the International
Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube
6
3
System of Units (SI): The Modern Metric System
Specimens)
C 128 Test Method for Specific Gravity and Absorption of
3. Terminology
4
Fine Aggregate
3.1 Definitions—Terms used in this specification are defined
C 140 Test Methods of Sampling and Testing Concrete
5
in Terminology C 219.
Masonry Units
3.2 Definition of Term Specific to This Standard:
C 151 Test Method for Autoclave Expansion of Portland
3
3.2.1 mortar cement—a hydraulic cement, primarily used in
Cement
masonry construction, consisting of a mixture of portland or
C 183 Practice for Sampling and the Amount of Testing of
3
blended hydraulic cement and plasticizing materials (such as
Hydraulic Cement
limestone or hydrated or hydraulic lime), together with other
materials introduced to enhance one or more properties such as
1
This specification is under the jurisdiction of ASTM Committee C01 on
setting time, workability, water retention, and durability.
Cement and is the direct responsibility of Subcommittee C01.11 on Masonry
3.2.1.1 Discussion—Mortar cement is similar to masonry
Cement.
cement in use and function. However, this specification re-
Current edition approved June 10, 2003. Published August 2003. Originally
approved in 1996. Last previous edition approved in 2003 as C 1329 – 03. quires lower air contents and includes a flexural bond strength
2
Annual Book of ASTM Standards, Vol 04.01. See the section on Safety
requirement.
Precautions in the Manual of Cement Testing.
3
Annual Book of ASTM Standards, Vol 04.01.
4
Annual Book of ASTM Standards, Vol 04.02.
5 6
Annual Book of ASTM Standards, Vol 04.05. Annual Book of ASTM Standards, Vol 14.04.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 1329 – 03a
4. Classification 11. Time of Setting
4.1 Mortar cement
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.