Standard Specification for Mortar Cement

SCOPE
1.1 This specification covers three types of mortar cement for use where mortar for masonry is required.
1.2 The values stated in SI units are to be regarded as the standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10, of measurements made in other units.
1.3 The text of this standard refers to notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 The following safety hazards caveat pertains only to Annex A1. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)

General Information

Status
Historical
Publication Date
31-Dec-2003
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1329-04 - Standard Specification for Mortar Cement
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1329 – 04
Standard Specification for
1
Mortar Cement
This standard is issued under the fixed designation C 1329; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 151 Test Method for Autoclave Expansion of Portland
Cement
1.1 This specification covers three types of mortar cement
C 183 Practice for Sampling and the Amount of Testing of
for use where mortar for masonry is required.
Hydraulic Cement
1.2 The values stated in SI units are to be regarded as the
C 185 Test Method for Air Content of Hydraulic Cement
standard. Values in SI units shall be obtained by measurement
Mortar
in SI units or by appropriate conversion, using the Rules for
C 187 Test Method for Normal Consistency of Hydraulic
Conversion and Rounding given in IEEE/ASTM SI 10, of
Cement
measurements made in other units.
C 188 Test Method for Density of Hydraulic Cement
1.3 The text of this standard refers to notes and footnotes
C 219 Terminology Relating to Hydraulic Cement
which provide explanatory material. These notes and footnotes
C 230/C 230M SpecificationforFlowTableforUseinTests
(excluding those in tables and figures) shall not be considered
of Hydraulic Cement
as requirements of the standard.
C 266 Test Method for Time of Setting of Hydraulic-
1.4 The following safety hazards caveat pertains only to
Cement Paste by Gillmore Needles
Section 16. This standard does not purport to address all of the
C 305 PracticeforMechanicalMixingofHydraulicCement
safety concerns, if any, associated with its use. It is the
Pastes and Mortars of Plastic Consistency
responsibility of the user of this standard to establish appro-
C 430 Test Method for Fineness of Hydraulic Cement by
priate safety and health practices and determine the applica-
the 45-µm (No. 325) Sieve
bility of regulatory limitations prior to use. (Warning—Fresh
C 511 Specification for Mixing Rooms, Moist Cabinets,
hydraulic cementitious mixtures are caustic and may cause
2
Moist Rooms, and Water Storage Tanks Used in the
chemical burns to skin and tissue upon prolonged exposure. )
Testing of Hydraulic Cements and Concretes
2. Referenced Documents
C 778 Specification for Standard Sand
3
C 780 Test Method for Preconstruction and Construction
2.1 ASTM Standards:
Evaluation of Mortars for Plain and Reinforced Unit
C 91 Specification for Masonry Cement
Masonry
C 109/C 109M Test Method for Compressive Strength of
C 1072 Test Method for Measurement of Masonry Flexural
Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube
Bond Strength
Specimens)
C 1357 Test Methods for Evaluating Masonry Bond
C 128 Test Method for Density, Relative Density (Specific
Strength
Gravity), and Absorption of Fine Aggregate
C 1506 Test Method for Water Retention of Hydraulic
C 140 Test Methods for Sampling and Testing Concrete
Cement-Based Mortars and Plasters
Masonry Units and Related Units
IEEE/ASTM SI 10 Standard for Use of the International
System of Units (SI): The Modern Metric System
1
This specification is under the jurisdiction of ASTM Committee C01 on
3. Terminology
Cement and is the direct responsibility of Subcommittee C01.11 on Masonry
Cement.
3.1 Definitions—Termsusedinthisspecificationaredefined
Current edition approved January 1, 2004. Published January 2004. Originally
in Terminology C 219.
approved in 1996. Last previous edition approved in 2003 as C 1329 – 03a.
2
3.2 Definition of Term Specific to This Standard:
Annual Book of ASTM Standards, Vol 04.01. See the section on Safety
Precautions in the Manual of Cement Testing.
3.2.1 mortar cement—a hydraulic cement, primarily used in
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
masonry construction, consisting of a mixture of portland or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
blended hydraulic cement and plasticizing materials (such as
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. limestone or hydrated or hydraulic lime), together with other
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1329–04
materials introduced to enhance one or more properties such as cabinet or room for 48 h 6 30 min before removal from the
setting time, workability, water retention, and durability. molds for measurement and testing in the autoclave. Calculate
3.2.1.1 Discussion—Mortar cement is similar to masonry the difference in length of the test specimen before and after
cement in use and function (See Specification C
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.