Standard Specification for Precast Concrete Septic Tanks

ABSTRACT
This specification covers monolithicor sectional precast concrete septic tanks. The following materials shall be used for manufacturing concrete septic tank: cement, aggregates, water, admixtures, steel reinforcement, concrete mixtures, forms, concrete placement, fibers, and sealants. The precast concrete sections shall be cured. Structural design of the septic tanks shall be by calculation or by performance. Concrete strength, reinforcing steel placement, and openings shall also be considered in the design. The physical design requirements include: capacity, shape, compartments, influent and effluent pipes, baffles and outlet devices, and openings in top slab. The following tests shall also be done: proof testing, leakage testing, vacuum testing, and water-pressure testing.
SCOPE
1.1 This specification covers design requirements, manufacturing practices, and performance requirements for monolithic or sectional precast concrete septic tanks.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Dec-2013
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1227-13 - Standard Specification for Precast Concrete Septic Tanks
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1227-13 - Standard Specification for Precast Concrete Septic Tanks
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1227 −13
Standard Specification for
1
Precast Concrete Septic Tanks
This standard is issued under the fixed designation C1227; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C39/C39M Test Method for Compressive Strength of Cylin-
drical Concrete Specimens
1.1 This specification covers design requirements, manufac-
C94/C94M Specification for Ready-Mixed Concrete
turing practices, and performance requirements for monolithic
C125 Terminology Relating to Concrete and Concrete Ag-
or sectional precast concrete septic tanks.
gregates
1.2 The values stated in inch-pound units are to be regarded
C150 Specification for Portland Cement
as standard. The values given in parentheses are mathematical
C231 Test Method for Air Content of Freshly Mixed Con-
conversions to SI units that are provided for information only
crete by the Pressure Method
and are not considered standard.
C260 Specification for Air-Entraining Admixtures for Con-
1.3 This standard does not purport to address all of the crete
safety concerns, if any, associated with its use. It is the
C330 Specification for Lightweight Aggregates for Struc-
responsibility of the user of this standard to establish appro- tural Concrete
priate safety and health practices and determine the applica-
C494/C494M Specification for Chemical Admixtures for
bility of regulatory limitations prior to use. Concrete
C595 Specification for Blended Hydraulic Cements
2. Referenced Documents
C618 Specification for Coal Fly Ash and Raw or Calcined
2
Natural Pozzolan for Use in Concrete
2.1 ASTM Standards:
C685/C685M Specification for Concrete Made by Volumet-
A82/A82M Specification for Steel Wire, Plain, for Concrete
3
ric Batching and Continuous Mixing
Reinforcement (Withdrawn 2013)
C890 Practice for Minimum Structural Design Loading for
A185/A185M Specification for Steel Welded Wire
3
Monolithic or Sectional Precast Concrete Water and
Reinforcement, Plain, for Concrete (Withdrawn 2013)
Wastewater Structures
A496/A496M Specification for Steel Wire, Deformed, for
3
C990 Specification for Joints for Concrete Pipe, Manholes,
Concrete Reinforcement (Withdrawn 2013)
and Precast Box Sections Using Preformed Flexible Joint
A497/A497M Specification for Steel Welded Wire
Sealants
Reinforcement, Deformed, for Concrete (Withdrawn
3
C1116/C1116M Specification for Fiber-Reinforced Concrete
2013)
C1644 Specification for Resilient Connectors Between Re-
A615/A615M SpecificationforDeformedandPlainCarbon-
inforced Concrete On-Site Wastewater Tanks and Pipes
Steel Bars for Concrete Reinforcement
4
A706/A706M Specification for Low-Alloy Steel Deformed 2.2 ACI Standard:
ACI 318 Building Code Requirements for Reinforced Con-
and Plain Bars for Concrete Reinforcement
A996/A996M Specification for Rail-Steel and Axle-Steel crete
5
Deformed Bars for Concrete Reinforcement 2.3 NSF/ANSI Standard:
C33 Specification for Concrete Aggregates NSF/ANSI46–2005 EvaluationofComponentsandDevices
used in Wastewater Treatment Systems
1
This specification is under the jurisdiction ofASTM Committee C27 on Precast
3. Terminology
ConcreteProductsandisthedirectresponsibilityofSubcommitteeC27.30onWater
3.1 For definitions of terms relating to concrete, see Termi-
and Wastewater Containers.
Current edition approved Dec. 15, 2013. Published January 2014. Originally
nology C125.
approved in 1993. Last previous edition approved in 2012 as C1227 – 12. DOI:
3.2 Definitions of Terms Specific to This Standard:
10.1520/C1227-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
4
Standards volume information, refer to the standard’s Document Summary page on Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
the ASTM website. Hills, MI 48333-9094, http://www.aci-int.org.
3 5
The last approved version of this historical standard is referenced on Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
www.astm.org. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1227 − 13
3.2.1 access opening, n—hole in the top slab used to gain 3.2.21 scum layer, n—buoyant waste floating near the sur-
access to the inside of the tank for the purpose of cleaning and face of liquid, consisting of lighter-than-water materials, such
removing sludge without a person actually having to enter the as greases and soaps.
tank.
3.2.22 sealed
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1227 − 12 C1227 − 13
Standard Specification for
1
Precast Concrete Septic Tanks
This standard is issued under the fixed designation C1227; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers design requirements, manufacturing practices, and performance requirements for monolithic or
sectional precast concrete septic tanks.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
3
A82/A82M Specification for Steel Wire, Plain, for Concrete Reinforcement (Withdrawn 2013)
3
A185/A185M Specification for Steel Welded Wire Reinforcement, Plain, for Concrete (Withdrawn 2013)
3
A496/A496M Specification for Steel Wire, Deformed, for Concrete Reinforcement (Withdrawn 2013)
3
A497/A497M Specification for Steel Welded Wire Reinforcement, Deformed, for Concrete (Withdrawn 2013)
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A996/A996M Specification for Rail-Steel and Axle-Steel Deformed Bars for Concrete Reinforcement
C33 Specification for Concrete Aggregates
C39/C39M Test Method for Compressive Strength of Cylindrical Concrete Specimens
C94/C94M Specification for Ready-Mixed Concrete
C125 Terminology Relating to Concrete and Concrete Aggregates
C150 Specification for Portland Cement
C231 Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
C260 Specification for Air-Entraining Admixtures for Concrete
C330 Specification for Lightweight Aggregates for Structural Concrete
C494/C494M Specification for Chemical Admixtures for Concrete
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C685/C685M Specification for Concrete Made by Volumetric Batching and Continuous Mixing
C890 Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete Water and Wastewater
Structures
C990 Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
C1116/C1116M Specification for Fiber-Reinforced Concrete
C1644 Specification for Resilient Connectors Between Reinforced Concrete On-Site Wastewater Tanks and Pipes
4
2.2 ACI Standard:
ACI 318 Building Code Requirements for Reinforced Concrete
1
This specification is under the jurisdiction of ASTM Committee C27 on Precast Concrete Products and is the direct responsibility of Subcommittee C27.30 on Water
and Wastewater Containers.
Current edition approved June 1, 2012Dec. 15, 2013. Published July 2012January 2014. Originally approved in 1993. Last previous edition approved in 20102012 as
C1227 – 10a.C1227 – 12. DOI: 10.1520/C1227-12.10.1520/C1227-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
4
Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.aci-int.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1227 − 13
5
2.3 NSF/ANSI Standard:
NSF/ANSI 46–2005 Evaluation of Components and Devices used in Wastewater Treatment Systems
3. Terminology
3.1 For definitions of terms relating to concrete, see Terminology C125.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 access opening, n—hole in the top slab used to gain access to the inside of the tank for the purpose of cleaning and
removing sludg
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.