Standard Test Method for Measurement of Evolved Formaldehyde from Water Reducible Air-Dry Coatings

SIGNIFICANCE AND USE
This test method measures the amount of formaldehyde that is released from a coating under laboratory conditions. The amount of formaldehyde available for release from a coating may vary depending on composition, and may decrease as the sample ages.
This test method may be used for typical air dried paints where water is the major volatile material. The useful range is estimated to be from 10 ppm to 1000 ppm formaldehyde in the sample.
Significant amounts of other volatile aldehydes, such as acetaldehyde, are reported to cause an interference with the determination of formaldehyde. This limitation is not expected to cause a problem for most common water reducible coatings.
Samples containing organic solvents as the major volatile component have not been evaluated and are not expected to be compatible with this test method.
SCOPE
1.1 This test method may be used to measure the amount of formaldehyde evolved from air-dry water reducible coatings utilizing latices, resin emulsions, or water reducible alkyds. The results may be used to define the “free” formaldehyde evolved from a sample under controlled laboratory conditions.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Oct-2008
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6191-97(2008)e1 - Standard Test Method for Measurement of Evolved Formaldehyde from Water Reducible Air-Dry Coatings
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation: D6191 − 97 (Reapproved2008)
Standard Test Method for
Measurement of Evolved Formaldehyde from Water
Reducible Air-Dry Coatings
This standard is issued under the fixed designation D6191; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
´ NOTE—The precaution note was moved into subsection 6.2 editorially in November 2008.
1. Scope 4.2 This test method may be used for typical air dried paints
where water is the major volatile material. The useful range is
1.1 This test method may be used to measure the amount of
estimated to be from 10 ppm to 1000 ppm formaldehyde in the
formaldehyde evolved from air-dry water reducible coatings
sample.
utilizing latices, resin emulsions, or water reducible alkyds.
The results may be used to define the “free” formaldehyde 4.3 Significant amounts of other volatile aldehydes, such as
evolved from a sample under controlled laboratory conditions. acetaldehyde, are reported to cause an interference with the
determination of formaldehyde. This limitation is not expected
1.2 This standard does not purport to address all of the
to cause a problem for most common water reducible coatings.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
4.4 Samples containing organic solvents as the major vola-
priate safety and health practices and determine the applica-
tilecomponenthavenotbeenevaluatedandarenotexpectedto
bility of regulatory limitations prior to use.
be compatible with this test method.
5. Apparatus
2. Referenced Documents
5.1 Formaldehyde CollectionApparatus, assembled using a
2.1 ASTM Standards:
flowmeter to control the nitrogen flow at ; 1.0 L/min, a 25 by
D2194 Test Method for Concentration of Formaldehyde
200 mm outside diameter long glass test tube, and two 30-mL
Solutions
midget impingers. Connections are made with glass tubes
3. Summary of Test Method
through a No. 4 two-hole rubber stopper and clear flexible
tubing (see Fig. 1).
3.1 A sample of water reducible coating is placed on the
walls of a test tube with a drawdown rod and purged with
5.2 Drawdown Bar, stainless steel No. 22 wire-wound
nitrogen. The evolved formaldehyde is collected in deionized
6.4-mm rod.
water with tandem impingers and measured colorimetrically
5.3 Glass Sample Bottles, (;2 oz), capable of holding
using acetylacetone at 412 nm.
30-mL solution.
5.4 Spectrophotometer, capable of measuring the absor-
4. Significance and Use
banceofsolutionsat412nmwithaminimumsamplelightpath
4.1 This test method measures the amount of formaldehyde
of 10 mm.
thatisreleasedfromacoatingunderlaboratoryconditions.The
amount of formaldehyde available for release from a coating
6. Reagents
may vary depending on composition, and may decrease as the
6.1 Acetylacetone Solution—Dissolve 150 6 0.1 g ammo-
sample ages.
nium acetate in ;600 mL deionized water in a 1-L volumetric
flask.Add 3.0-mLglacial acetic acid and 2.0-mLacetylacetone
(2,4 pentanedione) and dilute to volume.
This test method is under the jurisdiction of ASTM Committee D01 on Paint
and Related Coatings, Materials, andApplications and is the direct responsibility of
6.2 Formaldehyde Solution—Use 37 % in methanol/water,
Subcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.
commercial stock standard solution. If a commercially cali-
Current edition approved Nov. 1, 2008. Published November 2008. Originally
brated 37 % standard solution is not being used, the concen-
approved in 1997. Last previous edition approved in 2003 as D6191 – 97 (2003).
DOI: 10.1520/D6191-97R08E01.
tration of formaldehyde may determined in accordance with
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Test Method D2194. Then, the actual concentrations of the
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
working calibrations standards are to be calculated using the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. measured value. (Warning—Formaldehyde, acetylacetone,
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
´1
D6191 − 97 (2008)
8.4 With the nitrogen flowing, remove the impinger tube
from the No. 2 impinger. If the sampling liquid is less than the
original 15 mL volume, restore the volume to 15 mL while
rinsing the impinger tube with deionized water. Disconnect the
No. 1 impinger in the series and rinse the impinger tube with
deionized water in order to restore the volume to 15 mL. Pour
the No. 1 impinger solution, which should contain most of the
formaldehyde, into a ;2-oz. bottle. Use the No. 2
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.