Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation

ABSTRACT
This specification covers calcium silicate block and pipe thermal insulation for use on surfaces. Thermal insulation shall be of the following types: Type I; Type IA; and Type II. Calcium silicate thermal insulation shall consist principally of hydrous calcium silicate usually with the incorporation of fibrous reinforcement. The insulation shall conform to the physical requirements specified. Following test methods shall be performed: block insulation; pipe insulation; apparent thermal conductivity; linear shrinkage after heat soaking; flexural strength; compressive strength; mass loss by tumbling; hot surface performance; surface burning characteristics; stress corrosion performance; and moisture content by dry weight.
SCOPE
1.1 This specification covers calcium silicate block and pipe thermal insulation for use on surfaces with temperatures between 80 and 1700°F (27 to 927°C), unless otherwise agreed upon between the manufacturer and the purchaser.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
The following safety hazards caveat pertains only to the test method (Section 12) described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
28-Feb-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C533-07 - Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 533 – 07
Standard Specification for
1
Calcium Silicate Block and Pipe Thermal Insulation
This standard is issued under the fixed designation C533; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope High-Temperature Thermal Insulation Subjected to Soak-
ing Heat
1.1 Thisspecificationcoverscalciumsilicateblockandpipe
C390 Practice for Sampling and Acceptance of Thermal
thermal insulation for use on surfaces with temperatures
Insulation Lots
between80and1700°F(27to927°C),unlessotherwiseagreed
C411 Test Method for Hot-Surface Performance of High-
upon between the manufacturer and the purchaser.
Temperature Thermal Insulation
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
C421 Test Method for Tumbling Friability of Preformed
as the standard. The values given in parentheses are for
Block-Type Thermal Insulation
information only.
C446 Test Method for Breaking Load and Calculated
1.3 The following safety hazards caveat pertains only to the
3
Modulus of Rupture of Preformed Insulation for Pipes
test method (Section 12) described in this specification: This
C450 PracticeforFabricationofThermalInsulatingFitting
standard does not purport to address all of the safety concerns,
Covers for NPS Piping, and Vessel Lagging
if any, associated with its use. It is the responsibility of the user
C518 Test Method for Steady-State Thermal Transmission
of this standard to establish appropriate safety and health
Properties by Means of the Heat Flow Meter Apparatus
practices and determine the applicability of regulatory limita-
C585 Practice for Inner and Outer Diameters of Rigid
tions prior to use.
Thermal Insulation for Nominal Sizes of Pipe and Tubing
2. Referenced Documents
(NPS System)
2
C795 Specification for Thermal Insulation for Use in Con-
2.1 ASTM Standards:
tact with Austenitic Stainless Steel
C165 Test Method for Measuring Compressive Properties
C870 Practice for Conditioning of Thermal Insulating Ma-
of Thermal Insulations
terials
C168 Terminology Relating to Thermal Insulation
C 1045 Practice for Calculating Thermal Transmission
C177 Test Method for Steady-State Heat Flux Measure-
Properties Under Steady-State Conditions
ments and Thermal Transmission Properties by Means of
C1058 Practice for Selecting Temperatures for Evaluating
the Guarded-Hot-Plate Apparatus
and Reporting Thermal Properties of Thermal Insulation
C203 Test Methods for Breaking Load and Flexural Prop-
C 1114 TestMethodforSteady-StateThermalTransmission
erties of Block-Type Thermal Insulation
Properties by Means of the Thin-Heater Apparatus
C302 Test Method for Density and Dimensions of Pre-
C1616 Test Method for Determining the Moisture Content
formed Pipe-Covering-Type Thermal Insulation
of Inorganic Insulation Materials by Weight
C303 Test Method for Dimensions and Density of Pre-
E84 Test Method for Surface Burning Characteristics of
formed Block and Board−Type Thermal Insulation
Building Materials
C335 Test Method for Steady-State Heat Transfer Proper-
ties of Pipe Insulation
3. Terminology
C356 Test Method for Linear Shrinkage of Preformed
3.1 Definitions—For definitions used in this specification,
see Terminology C168.
1
This specification is under the jurisdiction of ASTM Committee C16 on
4. Classification
Thermal Insulation and is the direct responsibility of Subcommittee C16.20 on
Homogeneous Inorganic Thermal Insulations.
4.1 Thermal insulation shall be of the following types:
Current edition approved March 1, 2007. Published March 2007. Originally
4.1.1 Type I—Blockforuseonsurfacesattemperaturefrom
approved in 1964 to replace C344 and C345. Last previous edition approved in
140°F (60°C) to to 1200°F (649°C).
2004 as C533–04.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
3
the ASTM website. Withdrawn.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C533–07
4.1.2 Type I—Pipe for use on surfaces at temperature from (13-mm) increments. Thicknesses greater than 3 in. (76 mm)
140°F (60°C) to to 1200°F (649°C). shall be furnished in one or more layers as agreed upon by
4.1.3 Type IA—Block for use on surfaces at temperatures purchaser and manufacturer.
from 140°F (60°C) to to 1200°F (649°C). 7.1.2 Curved Block—Curved block shall be furnishe
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.