Standard Test Method for Zinc Analysis of Floor Polishes and Floor Polish Polymers By Flame Atomic Absorption (A.A.)

SIGNIFICANCE AND USE
2.1 This test method is generally accepted for the preparation of floor polish and floor polish polymers for the analysis of total zinc content. Knowing the total zinc content of a floor finish or polymer can aid in determining the proper disposal method of used or unwanted product.
SCOPE
1.1 This laboratory test method covers the analysis of floor polishes and floor polish polymers for total zinc content.  
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Sep-2016
Technical Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM D6827-02(2016) - Standard Test Method for Zinc Analysis of Floor Polishes and Floor Polish Polymers By Flame Atomic Absorption (A.A.)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6827-02(2016) - Standard Test Method for Zinc Analysis of Floor Polishes and Floor Polish Polymers By Flame Atomic Absorption (A.A.)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D6827 − 02 (Reapproved 2016)
Standard Test Method for
Zinc Analysis of Floor Polishes and Floor Polish Polymers
By Flame Atomic Absorption (A.A.)
This standard is issued under the fixed designation D6827; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 5.1.1 Before a sample can be run for total zinc, it must be
prepared so that any insoluble zinc will be solubilized and not
1.1 This laboratory test method covers the analysis of floor
removed by the filtering process. By preparing the sample in
polishes and floor polish polymers for total zinc content.
the following way, the analysis will be much more accurate
1.2 This standard does not purport to address all of the
(testing total zinc instead of soluble zinc). The prep method
safety concerns, if any, associated with its use. It is the
will also lessen the chance of clogging the nebulizer of the
responsibility of the user of this standard to establish appro-
atomic absorption unit with particulate matter.
priate safety and health practices and determine the applica-
5.2 Prep Method:
bility of regulatory limitations prior to use.
5.2.1 Important—All glassware used must be washed with
2. Significance and Use
1:1 nitric acid solution and rinsed with deionized water to
eliminate contamination.
2.1 This test method is generally accepted for the prepara-
5.2.2 Weigh approximately 50 g of sample into a 100–mL
tion of floor polish and floor polish polymers for the analysis of
beaker. Record the exact weight to 0.001 g on the analysis
total zinc content. Knowing the total zinc content of a floor
sheet.
finish or polymer can aid in determining the proper disposal
method of used or unwanted product. 5.2.3 Add approximately 5 mL of a 1:1 nitric acid solution
to the beaker. The amount need not be exact. Two disposable
3. Apparatus
pipets worth should be adequate.
5.2.4 Heat the sample to boiling in a hood. Allow the sample
3.1 Analytical Balance, accurate to 0.001 g.
to boil until approximately 40 mL of sample remain.
3.2 Hot Plate.
5.2.5 Cool the sample and filter into a 100–mL volumetric
3.3 Ventilation Hood.
flask. Rinse the beaker and filter into the volumetric flask with
deionized water.
4. Reagents and Materials
5.2.6 Bring the sample to volume with deionized water.
4.1 100 mL Beaker.
5.2.7 Analyze sample by flame A.A.
4.2 1:1 Nitric Acid Solution.
5.3 Sample Analysis:
4.3 Disposable Pipets.
5.3.1 The samples should
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6827 − 02 (Reapproved 2008) D6827 − 02 (Reapproved 2016)
Standard Test Method for
Zinc Analysis of Floor Polishes and Floor Polish Polymers
By Flame Atomic Absorption (A.A.)
This standard is issued under the fixed designation D6827; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This laboratory test method covers the analysis of floor polishes and floor polish polymers for total zinc content.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Significance and Use
2.1 This test method is generally accepted for the preparation of floor polish and floor polish polymers for the analysis of total
zinc content. Knowing the total zinc content of a floor finish or polymer can aid in determining the proper disposal method of used
or unwanted product.
3. Apparatus
3.1 Analytical Balance, accurate to 0.001 g.
3.2 Hot Plate.
3.3 Ventilation Hood.
4. Reagents and Materials
4.1 100 mL Beaker.
4.2 1:1 Nitric Acid Solution.
4.3 Disposable Pipets.
4.4 100-mL Volumetric Flask.
4.5 Deionized Water.
4.6 Filter Funnel.
4.7 Filter Paper.
5. Procedure
5.1 Sample Preparation:
5.1.1 Before a sample can be run for total zinc, it must be prepared so that any insoluble zinc will be solubilized and not
removed by the filtering process. By preparing the sample in the following way, the analysis will be much more accurate (testing
total zinc instead of soluble zinc). The prep method will also lessen the chance of clogging the nebulizer of the atomic absorption
unit with particulate matter.
5.2 Prep Method:
5.2.1 Important—All glassware used must be washed with 1:1 nitric acid solution and rinsed with deionized water to eliminate
contamination.
5.2.2 Weigh approximately 50 g of sample into a 100–mL beaker. Record the exact weight to 0.001 g on the analysis sheet.
This test method is under the jurisdiction of ASTM Committee D21 on Polishes and is the direct responsibility of Subcommittee D21.03 on Chemical and Physical
Testing.
Current edition approved March 1, 2008Oct. 1, 2016. Published April 2008October 2016. Originally approved in 2002. Last previ
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.