Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles

SIGNIFICANCE AND USE
5.1 The purpose of this test method is to establish whether a cement complies with a specification limit on Gillmore time of setting.
SCOPE
1.1 This test method covers the determination of the time of setting of hydraulic-cement paste by means of the Gillmore needles.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)2  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Sep-2021
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C266-21 - Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C266-21 - Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: C266 − 21
Standard Test Method for
Time of Setting of Hydraulic-Cement Paste by Gillmore
1
Needles
This standard is issued under the fixed designation C266; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C151/C151M Test Method for Autoclave Expansion of Hy-
draulic Cement
1.1 This test method covers the determination of the time of
C183/C183M Practice for Sampling and the Amount of
setting of hydraulic-cement paste by means of the Gillmore
Testing of Hydraulic Cement
needles.
C187 Test Method for Amount of Water Required for Nor-
1.2 The values stated in SI units are to be regarded as
mal Consistency of Hydraulic Cement Paste
standard. No other units of measurement are included in this
C219 Terminology Relating to Hydraulic and Other Inor-
standard.
ganic Cements
1.3 The text of this standard references notes and footnotes C305 Practice for Mechanical Mixing of Hydraulic Cement
Pastes and Mortars of Plastic Consistency
which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered C511 Specification for Mixing Rooms, Moist Cabinets,
Moist Rooms, and Water Storage Tanks Used in the
as requirements of the standard.
Testing of Hydraulic Cements and Concretes
1.4 This standard does not purport to address all of the
C670 Practice for Preparing Precision and Bias Statements
safety concerns, if any, associated with its use. It is the
for Test Methods for Construction Materials
responsibility of the user of this standard to establish appro-
C1005 Specification for Reference Masses and Devices for
priate safety, health, and environmental practices and deter-
DeterminingMassandVolumeforUseinPhysicalTesting
mine the applicability of regulatory limitations prior to use.
of Hydraulic Cements
(Warning—Fresh hydraulic cementitious mixtures are caustic
and may cause chemical burns to skin and tissue upon
3. Terminology
2
prolonged exposure.)
3.1 Definitions:
1.5 This international standard was developed in accor-
3.1.1 For definitions of terms used in this test method, refer
dance with internationally recognized principles on standard-
to Terminology C219.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
4. Summary of Test Method
mendations issued by the World Trade Organization Technical
4.1 Sufficient water is added to the cement that is being
Barriers to Trade (TBT) Committee.
tested to produce a paste of normal consistency.Aspecimen is
molded from this paste and is tested for time of setting by
2. Referenced Documents
means of the Gillmore initial and final needles.The initial time
3
2.1 ASTM Standards:
of setting is the time elapsed between initial contact of cement
and water and the time when the Gillmore Initial needle does
not leave a complete circular impression in the paste surface.
1
This test method is under the jurisdiction ofASTM Committee C01 on Cement The final time of setting is the time elapsed between initial
and is the direct responsibility of Subcommittee C01.30 on Time of Set.
contact of cement and water and the time when the Gillmore
Current edition approved Oct. 1, 2021. Published November 2021. Originally
Final needle does not leave a complete circular impression in
approved in 1951. Last previous edition approved in 2020 as C266 – 20. DOI:
the paste surface.
10.1520/C0266-21.
2
Section on Safety, Manual of Cement Testing, Annual Book of ASTM
5. Significance and Use
Standards, Vol 04.01.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
5.1 The purpose of this test method is to establish whether
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
a cement complies with a specification limit on Gillmore time
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
of setting.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C266 − 21
6. Apparatus 10. Procedure
6.1 Flat Trowel, having a sharpened straight-edged steel
10.1 PreparationofCementPaste—Obtainthecementpaste
blade 100 to 150 mm in length. The edges when placed on a
used for determination of the time of setting from one of the
plane surface shall not depart from
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C266 − 20 C266 − 21
Standard Test Method for
Time of Setting of Hydraulic-Cement Paste by Gillmore
1
Needles
This standard is issued under the fixed designation C266; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the determination of the time of setting of hydraulic-cement paste by means of the Gillmore needles.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns
2
to skin and tissue upon prolonged exposure.)
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
3
2.1 ASTM Standards:
C151/C151M Test Method for Autoclave Expansion of Hydraulic Cement
C183/C183M Practice for Sampling and the Amount of Testing of Hydraulic Cement
C187 Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste
C219 Terminology Relating to Hydraulic and Other Inorganic Cements
C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic
Cements and Concretes
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
C1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in Physical Testing of
Hydraulic Cements
D1193 Specification for Reagent Water
1
This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.30 on Time of Set.
Current edition approved Oct. 1, 2020Oct. 1, 2021. Published November 2020November 2021. Originally approved in 1951. Last previous edition approved in 20182020
as C266 – 18.C266 – 20. DOI: 10.1520/C0266-20.10.1520/C0266-21.
2
Section on Safety, Manual of Cement Testing, Annual Book of ASTM Standards, Vol 04.01.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C266 − 21
3. Terminology
3.1 Definitions:
3.1.1 For definitions of terms used in this test method, refer to Terminology C219.
4. Summary of Test Method
4.1 Sufficient water is added to the cement that is being tested to produce a paste of normal consistency. A specimen is molded
from this paste and is tested for time of setting by means of the Gillmore initial and final needles. The initial time of setting is the
time elapsed between initial contact of cement and water and the time when the Gillmore Initial needle does not leave a complete
circular impression in the paste surface. The final time of setting is the time elapsed between initial contact of cement and water
and the time when the Gillmore Final needle does not leave a complete circular impression in the paste surface.
5. Significance and Use
5.1 The purpose of this test method is to establish whether a cement complies with a specification limit on Gillmore time of setting.
6. Apparatus
6.1 Flat Trowel, having a sharpened straight-edged steel
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.