ASTM E1851-15
(Test Method)Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
SIGNIFICANCE AND USE
5.1 This standard provides measurement procedures for determining the electromagnetic shielding effectiveness of durable rigid wall relocatable shielded enclosures. This standard specifies a method for comparing the shielded enclosure performance of structures provided by different suppliers. In addition, this standard is written to minimize variations in measured shielding effectiveness at a given frequency and test point regardless of test personnel, equipment, and test site. Therefore, the shielding effectiveness of a durable rigid wall relocatable shielded enclosure of any size from any supplier can be determined. This standard specifies a minimum set of measurements at a given frequency and a minimum set of frequencies to determine shielding effectiveness.
5.2 Source Fields—Performance of a shielded enclosure is to be assessed for two source fields: magnetic and plane wave.
5.2.1 Magnetic Field Measurements—The attenuation provided by a shielded enclosure is assessed by using a local source to generate the near field. The magnetic field measurements are specified for two narrow frequency bands: 140 to 160 kHz and 14 to 16 MHz.
5.2.2 Plane Wave Measurements—The attenuation provided by a shielded enclosure is assessed by using a locally generated distant source or plane wave field. The plane wave measurements are specified for three narrow frequency bands: 300 to 500 MHz, 900 to 1000 MHz, and 8.5 to 10.5 GHz.
SCOPE
1.1 This test method covers the determination of the electromagnetic shielding effectiveness of durable relocatable shielded enclosures.
1.1.1 The intended application of this test method is for virgin shielded enclosures that do not have any equipment or equipment racks. It is recommended that tests be conducted before the interior finish work begins. However, the shield assembly including all enclosure penetrations shall be completed and required penetration protection devices shall be installed in accordance with the design specification. The test method can also be used on existing shielded enclosures after repair work is done to verify workmanship, but it may be necessary to remove equipment or equipment racks to gain access to a test area.
1.1.2 The test procedures delineated in this document are comprehensive and may require several days to complete for a room-size shielded enclosure. A user can apply this test method for a first article test that requires proof of concept and validation of design and fabrication technique. Appendix X2 provides guidance on choosing test points so shielding effectiveness tests on a room-size shielded enclosure may be completed in about one-half day for which it applies to shielded enclosures coming off an assembly line.
1.2 This test method is for use in the following frequency ranges: 140 to 160 kHz, 14 to 16 MHz, 300 to 500 MHz, 900 to 1000 MHz, and 8.5 to 10.5 GHz. Specific test frequencies within these ranges are required (see 11.1.1 and 11.2.1). Additional measurements in the range of 10 kHz to 10.5 GHz may be performed. For specific applications, the frequency range may be extended from 50 Hz to 40 GHz. Appendix X1 provides guidance on selecting measurement frequencies.
1.3 This test method is not applicable to individual components such as separate walls, floors, ceilings, or shielded racks.
1.4 This standard may involve hazardous materials, operations, equipment, or any combination.
1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E1851 −15
Standard Test Method for
Electromagnetic Shielding Effectiveness of Durable Rigid
1
Wall Relocatable Structures
This standard is issued under the fixed designation E1851; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope 1.3 This test method is not applicable to individual compo-
nents such as separate walls, floors, ceilings, or shielded racks.
1.1 This test method covers the determination of the elec-
1.4 This standard may involve hazardous materials,
tromagnetic shielding effectiveness of durable relocatable
shielded enclosures. operations, equipment, or any combination.
1.1.1 The intended application of this test method is for
1.5 The values stated in SI units are to be regarded as the
virgin shielded enclosures that do not have any equipment or
standard. The values in parentheses are for information only.
equipment racks. It is recommended that tests be conducted
1.6 This standard does not purport to address all of the
before the interior finish work begins. However, the shield
safety concerns, if any, associated with its use. It is the
assembly including all enclosure penetrations shall be com-
responsibility of the user of this standard to establish appro-
pleted and required penetration protection devices shall be
priate safety and health practices and determine the applica-
installed in accordance with the design specification. The test
bility of regulatory limitations prior to use.
method can also be used on existing shielded enclosures after
repair work is done to verify workmanship, but it may be 2. Referenced Documents
2
necessary to remove equipment or equipment racks to gain
2.1 ASTM Standards:
access to a test area.
E631Terminology of Building Constructions
1.1.2 The test procedures delineated in this document are
E1749Terminology Relating to Rigid Wall Relocatable
comprehensive and may require several days to complete for a
Shelters
3
room-sizeshieldedenclosure.Ausercanapplythistestmethod
2.2 IEEE Standards:
for a first article test that requires proof of concept and
IEEE Std299-1997IEEE Standard Method for Measuring
validation of design and fabrication technique. Appendix X2
theEffectivenessofElectromagneticShieldingEnclosures
provides guidance on choosing test points so shielding effec-
IEEEStdC95.1-1991 IEEEStandardforSafetyLevelswith
tiveness tests on a room-size shielded enclosure may be
Respect to Human Exposure to Radio Frequency Electro-
completed in about one-half day for which it applies to
magnetic Fields, 3 kHz to 300 GHz
4
shielded enclosures coming off an assembly line.
2.3 Military Standard:
1.2 This test method is for use in the following frequency MIL-STD-188-125 High Altitude Electromagnetic Pulse
4
(HEMP) Protection for Ground Based C I Facilities Per-
ranges: 140 to 160 kHz, 14 to 16 MHz, 300 to 500 MHz, 900
to 1000 MHz, and 8.5 to 10.5 GHz. Specific test frequencies forming Critical, Time-Urgent Missions
5
2.4 OSHA Standard:
within these ranges are required (see 11.1.1 and 11.2.1).
Additional measurements in the range of 10 kHz to 10.5 GHz OSHARegulation,29CFR1910,DepartmentofLabor,July
1992
may be performed. For specific applications, the frequency
range may be extended from 50 Hz to 40 GHz. Appendix X1
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
provides guidance on selecting measurement frequencies.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
1 3
This test method is under the jurisdiction of ASTM Committee E06 on Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE),
Performance of Buildings and is the direct responsibility of Subcommittee E06.53 445 Hoes Ln., Piscataway, NJ 08854-4141, http://www.ieee.org.
4
on Materials and Processes for Durable Rigidwall Relocatable Structures. Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
Current edition approved Sept. 1, 2015. Published September 2015. Originally Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
5
approved in 1997. Last previous edition approved in 2009 as E1851-09. DOI: Available from Occupational Safety and Health Administration (OSHA), 200
10.1520/E1851-15. Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ---------------
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1851 − 09 E1851 − 15
Standard Test Method for
Electromagnetic Shielding Effectiveness of Durable Rigid
1
Wall Relocatable Structures
This standard is issued under the fixed designation E1851; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This test method covers the determination of the electromagnetic shielding effectiveness of durable relocatable shielded
enclosures.
1.1.1 The intended application of this test method is for virgin shielded enclosures that do not have any equipment or equipment
racks. It is recommended that tests be conducted before the interior finish work begins. However, the shield assembly including
all enclosure penetrations shall be completed and required penetration protection devices shall be installed in accordance with the
design specification. The test method can also be used on existing shielded enclosures after repair work is done to verify
workmanship, but it may be necessary to remove equipment or equipment racks to gain access to a test area.
1.1.2 The test procedures delineated in this document are comprehensive and may require several days to complete for a
room-size shielded enclosure. A user can apply this test method for a first article test that requires proof of concept and validation
of design and fabrication technique. Appendix X2 provides guidance on choosing test points so shielding effectiveness tests on a
room-size shielded enclosure may be completed in about one-half day for which it applies to shielded enclosures coming off an
assembly line.
1.2 This test method is for use in the following frequency ranges: 140 to 160 kHz, 14 to 16 MHz, 300 to 500 MHz, 900 to 1000
MHz, and 8.5 to 10.5 GHz. Specific test frequencies within these ranges are required (see 10.1.111.1.1 and 11.2.110.2.1).).
Additional measurements in the range of 10 kHz to 10.1.5.110.5 GHz may be performed. For specific applications, the frequency
range may be extended from 50 Hz to 40 GHz. Appendix X1 provides guidance on selecting measurement frequencies.
1.3 This test method is not applicable to individual components such as separate walls, floors, ceilings, or shielded racks.
1.4 This standard may involve hazardous materials, operations, equipment, or any combination.
1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
E631 Terminology of Building Constructions
E1749 Terminology Relating to Rigid Wall Relocatable Shelters
3
2.2 IEEE Standards:
IEEE Std 299-1997 IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures
IEEE Std C95.1-1991 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic
Fields, 3 kHz to 300 GHz
1
This test method is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.53 on Materials
and Processes for Durable Rigidwall Relocatable Structures.
Current edition approved Nov. 1, 2009Sept. 1, 2015. Published December 2009September 2015. Originally approved in 1997. Last previous edition approved in 20042009
as E1851 – 04.E1851-09. DOI: 10.1520/E1851-09.10.1520/E1851-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE), 445 Hoes Ln., P.O. Box 1331, Piscataway, NJ 08854-1331,08854-4141, http://www.ieee.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E1851 − 15
4
2.3 Military Standard:
4
MIL-STD-188-125 High Altitude Electromagnetic Pulse (HEMP)
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.