ASTM D6142-08
(Test Method)Standard Test Method for Analysis of Phenol by Capillary Gas Chromatography
Standard Test Method for Analysis of Phenol by Capillary Gas Chromatography
SIGNIFICANCE AND USE
This test method is suitable for setting specifications on phenol and for use as an internal quality control tool where phenol is produced or is used in a manufacturing process. It may also be used in development or research work involving phenol. It is generally applied to determining those commonly occurring impurities such as mesityl oxide, cumene, hydroxyacetone, acetone, alpha-methylstyrene, 2-methylbenzofuran, acetophenone, o-cresol, and m & p-cresol.
Purity is commonly reported by subtracting the determined expected impurities from 100.00. However, a gas chromatographic analysis cannot determine absolute purity if water is present or unknown components are contained within the material being examined.
SCOPE
1.1 This test method covers the determination of known impurities in phenol by gas chromatography (GC). It is generally meant for the analysis of phenol of 99.9 % or greater purity.
1.2 This test method has been found applicable over impurity concentrations of 15 to 70 mg/kg. Users of this method believe it is linear over a wider range.
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
Designation: D6142 − 08
Standard Test Method for
1
Analysis of Phenol by Capillary Gas Chromatography
This standard is issued under the fixed designation D6142; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* E29 Practice for Using Significant Digits in Test Data to
Determine Conformance with Specifications
1.1 This test method covers the determination of known
E355 Practice for Gas ChromatographyTerms and Relation-
impurities in phenol by gas chromatography (GC). It is
ships
generally meant for the analysis of phenol of 99.9 % or greater
E691 Practice for Conducting an Interlaboratory Study to
purity.
Determine the Precision of a Test Method
1.2 This test method has been found applicable over impu-
E1510 Practice for Installing Fused Silica Open Tubular
rity concentrations of 15 to 70 mg/kg. Users of this method
Capillary Columns in Gas Chromatographs
believe it is linear over a wider range.
2.2 Other Document:
1.3 In determining the conformance of the test results using
OSHA Regulations, 29 CFR paragraphs 1910.1000 and
3
this method to applicable specifications, results shall be
1910.1200
rounded off in accordance with the rounding-off method of
Practice E29.
3. Terminology
1.4 The values stated in SI units are to be regarded as
3.1 See Terminology D4790 for definition of terms used in
standard. No other units of measurement are included in this
this test method.
standard.
4. Summary of Test Method
1.5 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
4.1 A known amount of an internal standard is added to a
responsibility of the user of this standard to establish appro-
sample of phenol. The prepared sample is mixed and analyzed
priate safety and health practices and determine the applica-
by a gas chromatograph equipped with a flame ionization
bility of regulatory limitations prior to use. For specific hazard
detector (FID).The peak area of each impurity and the internal
statements, see Section 9.
standard is measured. The amount of each impurity is calcu-
lated from the ratio of the peak area of the internal standard
2. Referenced Documents
versus the peak area of the impurity. Results are reported in
2
2.1 ASTM Standards:
milligrams per kilogram.
D3852 Practice for Sampling and Handling Phenol, Cresols,
and Cresylic Acid
5. Significance and Use
D4307 Practice for Preparation of Liquid Blends for Use as
5.1 This test method is suitable for setting specifications on
Analytical Standards
phenol and for use as an internal quality control tool where
D4790 Terminology ofAromatic Hydrocarbons and Related
phenol is produced or is used in a manufacturing process. It
Chemicals
may also be used in development or research work involving
D6809 Guide for Quality Control and Quality Assurance
phenol. It is generally applied to determining those commonly
Procedures for Aromatic Hydrocarbons and Related Ma-
occurring impurities such as mesityl oxide, cumene, hydroxy-
terials
acetone, acetone, alpha-methylstyrene, 2-methylbenzofuran,
acetophenone, o-cresol, and m & p-cresol.
1
This test method is under the jurisdiction of ASTM Committee D16 on
5.2 Purity is commonly reported by subtracting the deter-
Aromatic Hydrocarbons and Related Chemicals and is the direct responsibility of
mined expected impurities from 100.00. However, a gas
Subcommittee D16.02 on Oxygenated Aromatics.
Current edition approved Dec. 1, 2008. Published December 2008. Originally chromatographic analysis cannot determine absolute purity if
approved in 1997. Last previous edition approved in 2003 as D6142 - 03. DOI:
10.1520/D6142-08.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM AvailablefromU.S.GovernmentPrintingOfficeSuperintendentofDocuments,
Standards volume information, refer to the standard’s Document Summary page on 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://
the ASTM website. www.access.gpo.gov.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
D6142 − 08
TABLE 1 Instrument Conditions for Phenol Analysis
Column: To use for identification of all but cresols To use for identification
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D6142–03 Designation: D 6142 – 08
Standard Test Method for
1
Analysis of Phenol by Capillary Gas Chromatography
This standard is issued under the fixed designation D 6142; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 Thistestmethodcoversthedeterminationofknownimpuritiesinphenolbygaschromatography(GC).Itisgenerallymeant
for the analysis of phenol of 99.9 % or greater purity.
1.2The following applies to all specified limits in this test method: for purposes of determining conformance with this test
method, an observed value or calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in
expressing the specification limit in accordance with the rounding-off method of Practice E29. Precision data is based on impurity
concentrations of 15 to 70 mg/kg. Users of this test method believe it is linear over a wider range.
1.3
1.2 This test method has been found applicable over impurity concentrations of 15 to 70 mg/kg. Users of this method believe
it is linear over a wider range.
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded
off in accordance with the rounding-off method of Practice E 29.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific hazard statements, see Section 9.
2. Referenced Documents
2
2.1 ASTM Standards:
D 3852 Practice for Sampling and Handling Phenol, Cresols, and Cresylic Acid
D 4307 Practice for Preparation of Liquid Blends for Use as Analytical Standards
2
D 4790 Terminology of Aromatic Hydrocarbons and Related Chemicals
Terminology of Aromatic Hydrocarbons and Related Chemicals
D 6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
E 355 Practice for Gas Chromatography Terms and Relationships
E 691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E 1510 Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
2.2 Other Document:
3
OSHA Regulations, 29 CFR paragraphs 1910.1000 and 1910.1200
3. Terminology
3.1 See Terminology D 4790 for definition of terms used in this test method.
4. Summary of Test Method
4.1 A known amount of an internal standard is added to a sample of phenol. The prepared sample is mixed and analyzed by
a gas chromatograph equipped with a flame ionization detector (FID). The peak area of each impurity and the internal standard
1
This test method is under the jurisdiction ofASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility of Subcommittee
D16.02 on Oxygenated Aromatics.
Current edition approved Feb. 10, 2003. Published April 2003. Originally approved in 1997. Last previous edition approved in 1997 as D6142-97.
Current edition approved Dec. 1, 2008. Published December 2008. Originally approved in 1997. Last previous edition approved in 2003 as D 6142 - 03.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. ForAnnualBookofASTMStandards
, Vol 06.04.volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Annual Book of ASTM Standards, Vol 14.02.
3
Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://
www.access.gpo.gov.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D6142–08
is measured. The amount of each impurity is calculated from the ratio of the peak area of the internal standard versus the peak
area of the impurity. Results are r
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:D6142–03 Designation: D 6142 – 08
Standard Test Method for
1
Analysis of Phenol by Capillary Gas Chromatography
This standard is issued under the fixed designation D 6142; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 Thistestmethodcoversthedeterminationofknownimpuritiesinphenolbygaschromatography(GC).Itisgenerallymeant
for the analysis of phenol of 99.9 % or greater purity.
1.2The following applies to all specified limits in this test method: for purposes of determining conformance with this test
method, an observed value or calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in
expressing the specification limit in accordance with the rounding-off method of Practice E29. Precision data is based on impurity
concentrations of 15 to 70 mg/kg. Users of this test method believe it is linear over a wider range.
1.3
1.2 This test method has been found applicable over impurity concentrations of 15 to 70 mg/kg. Users of this method believe
it is linear over a wider range.
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded
off in accordance with the rounding-off method of Practice E 29.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific hazard statements, see Section 9.
2. Referenced Documents
2
2.1 ASTM Standards:
D 3852 Practice for Sampling and Handling Phenol, Cresols, and Cresylic Acid
D 4307 Practice for Preparation of Liquid Blends for Use as Analytical Standards
2
D 4790 Terminology of Aromatic Hydrocarbons and Related Chemicals
Terminology of Aromatic Hydrocarbons and Related Chemicals
D 6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
E 355 Practice for Gas Chromatography Terms and Relationships
E 691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E 1510 Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs
2.2 Other Document:
3
OSHA Regulations, 29 CFR paragraphs 1910.1000 and 1910.1200
3. Terminology
3.1 See Terminology D 4790 for definition of terms used in this test method.
4. Summary of Test Method
4.1 A known amount of an internal standard is added to a sample of phenol. The prepared sample is mixed and analyzed by
a gas chromatograph equipped with a flame ionization detector (FID). The peak area of each impurity and the internal standard
1
This test method is under the jurisdiction ofASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility of Subcommittee
D16.02 on Oxygenated Aromatics.
Current edition approved Feb. 10, 2003. Published April 2003. Originally approved in 1997. Last previous edition approved in 1997 as D6142-97.
Current edition approved Dec. 1, 2008. Published December 2008. Originally approved in 1997. Last previous edition approved in 2003 as D 6142 - 03.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. ForAnnualBookofASTMStandards
, Vol 06.04.volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Annual Book of ASTM Standards, Vol 14.02.
3
Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://
www.access.gpo.gov.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D6142–08
is measured. The amount of each impurity is calculated from the ratio of the peak area of the internal standard versus the peak
area of the impurity. Results are r
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.