Standard Specification for Folder/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural pipe-within-a-pipe.
Note 1—For installation procedures refer to Practice F 1867.
1.3 This specification includes pipe made only from materials specified in Section . This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
1.5 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6 There is no similar or equivalent ISO Standard.

General Information

Status
Historical
Publication Date
09-Jul-1998
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1871-98e1 - Standard Specification for Folder/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
e1
Designation: F 1871 – 98
Standard Specification for
Folded/Formed Poly (Vinyl Chloride) Pipe Type A for
1
Existing Sewer and Conduit Rehabilitation
This standard is issued under the fixed designation F 1871; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Sections 6.1 and 15.2.3 and Table 1 were editorially updated in July 2002.
1. Scope and Reinforced Plastics and Electrical Insulating Materi-
2
als
1.1 This specification covers requirements and test methods
D 1600 Terminology for Abbreviated Terms Relating to
for materials, dimensions, workmanship, flattening resistance,
2
Plastics
impact resistance, pipe stiffness, extrusion quality, and a form
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
of marking for folded/formed poly (vinyl chloride) (PVC) pipe
Compounds and Chlorinated Poly(Vinyl Chloride)
for existing sewer and conduit rehabilitation.
2
(CPVC) Compounds
1.2 Pipe produced to this specification is for use in non-
D 2122 Test Method for Determining Dimensions of Ther-
pressure sewer and conduit rehabilitation where the folded
3
moplastic Pipe and Fittings
PVC pipe is installed into and then expanded to provide a close
D 2152 Test Method for Adequacy of Fusion of Extruded
fit to the wall of the original conduit, forming a new structural
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
pipe-within-a-pipe.
3
Acetone Immersion
NOTE 1—For installation procedures refer to Practice F 1867.
D 2412 Test Method for Determination of External Loading
3
1.3 This specification includes pipe made only from mate- Characteristics of Plastic Pipe by Parallel-Plate Loading
rials specified in Section 6. This specification does not include D 2444 Test Method for Determination of Impact Resis-
pipe manufactured from reprocessed, recycled, or reclaimed tance of Thermoplastic Pipe and Fittings by Means of a
3
PVC. Tup (Falling Weight)
3
1.4 The values stated in inch-pound units are to be regarded F 412 Terminology Relating to Plastic Piping Systems
as the standard. The SI units given in parentheses are provided F 1057 Practice for Estimating the Quality of Extruded
for information only. Poly(Vinyl Chloride) (PVC) Pipe by Heat Reversion Tech-
3
1.5 The following precautionary statement pertains only to nique
the test method portion, Section 11, of this specification. This F 1867 Practice for Installation of Folded/Formed Poly
standard does not purport to address all of the safety concerns, (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer
3
if any, associated with its use. It is the responsibility of the user and Conduit Rehabilitation
4
of this standard to establish appropriate safety and health 2.2 Federal Standard:
practices and determine the applicability of regulatory limita- Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
4
tions prior to use. 2.3 Military Standard:
1.6 There is no similar or equivalent ISO Standard. MIL-STD-129 Marking for Shipment and Storage
2. Referenced Documents 3. Terminology
2.1 ASTM Standards: 3.1 Definitions: Definitions are in accordance with Termi-
2
D 618 Practice for Conditioning Plastics for Testing nology F 412, and abbreviations are in accordance with Ter-
2
D 638 Test Method for Tensile Properties of Plastics minology D 1600, unless otherwise specified. The abbreviation
D 648 Test Method for Deflection Temperature of Plastics for poly(vinyl chloride) plastics is PVC.
2
Under Flexural Load 3.1.1 The term TYPE A is not an abbreviation, but rather an
D 790 Test Method for Flexural Properties of Unreinforced arbitrary designation for PVC compounds with a minimum
value for modulus in tension as listed in 6.1 and a maximum
value as defined by cell limit 1 of Specification D 1784.
1
This standard is under the jurisdiction of Committee F17 on Plastic Piping
Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless
3
Plastic Pipline Technology. Annual Book of ASTM Standards, Vol 08.04.
4
Current edition approved July 10, 1998. Published September 1998. Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
2
Annual Book of ASTM Standards, Vol 08.01. Robbins Ave., Philadelphia, PA 19111–5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 1871
3.2 Definitions of Terms Specific to This Standard: installation in
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.