ASTM D2054-99(2004)
(Test Method)Standard Test Method for Colorfastness of Zipper Tapes to Crocking
Standard Test Method for Colorfastness of Zipper Tapes to Crocking
SIGNIFICANCE AND USE
This test method is considered satisfactory for acceptance testing of commercial shipments because the method has been used extensively in the trade for acceptance testing.
5.1.1 If there are differences of practical significance between reported test results for two laboratories (or more), comparative tests should be performed to determine if their is a statistical bias between them, using competent statistical assistance. As a minimum, the test samples should be used that are as homogeneous as possible, that are drawn from the material from which the disparate test results were obtained, and that are randomly assigned in equal numbers to each laboratory for testing. Other materials with established test values may be used for this purpose. The test results from the two laboratories should be compared using a statistical test for unpaired data, at a probability level chosen prior to the testing series. If a bias is found, either its cause must be found and corrected, or future test results must be adjusted in consideration of the known bias.
SCOPE
1.1 This test method covers the determination of the degree of color that may be transferred from the textile tape of zippers of all fibers to other surfaces by rubbing under wet or dry conditions, or both.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as the standard. Within the text, the inch-pound units are shown in parentheses. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this test method.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D2054–99 (Reapproved 2004)
Standard Test Method for
Colorfastness of Zipper Tapes to Crocking
This standard is issued under the fixed designation D2054; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Summary of Test Method
1.1 This test method covers the determination of the degree 4.1 A specimen of the zipper tape fastened to the base of a
of color that may be transferred from the textile tape of zippers crockmeter is rubbed with white crock test cloth under con-
of all fibers to other surfaces by rubbing under wet or dry trolled conditions. Color transferred to the white test cloth is
conditions, or both. assessed by a comparison with the AATCC Chromatic Trans-
1.2 The values stated in either SI units or inch-pound units ference Scale.
are to be regarded separately as the standard. Within the text,
5. Significance and Use
the inch-pound units are shown in parentheses. The values
5.1 This test method is considered satisfactory for accep-
stated in each system are not exact equivalents; therefore, each
system shall be used independently of the other. Combining tance testing of commercial shipments because the method has
been used extensively in the trade for acceptance testing.
values from the two systems may result in nonconformance
with this test method. 5.1.1 If there are differences of practical significance be-
tween reported test results for two laboratories (or more),
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the comparative tests should be performed to determine if their is
a statistical bias between them, using competent statistical
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- assistance.As a minimum, the test samples should be used that
are as homogeneous as possible, that are drawn from the
bility of regulatory limitations prior to use.
material from which the disparate test results were obtained,
2. Referenced Documents
and that are randomly assigned in equal numbers to each
2.1 ASTM Standards: laboratory for testing. Other materials with established test
D123 Terminology Relating to Textiles values may be used for this purpose. The test results from the
D1776 Practice for Conditioning and Testing Textiles two laboratories should be compared using a statistical test for
D2050 Terminology Relating to Subassemblies unpaired data, at a probability level chosen prior to the testing
2.2 AATCC Methods: series. If a bias is found, either its cause must be found and
Method 8 Colorfastness to Crocking: corrected, or future test results must be adjusted in consider-
AATCC Crockmeter Method ation of the known bias.
AATCC Chromatic Transference Scale
6. Apparatus
3. Terminology
6.1 Apparatus, as specified in AATCC Test Method 8.
3.1 Definitions—For definitions of zipper terms used in this 6.2 Smooth Cardboard Cards, 50 by 200 mm (2 by 8 in.)
standard, refer to Terminology D2050. For definitions of other approximating index card weight.
textile terminology used in this standard, refer to Terminology
7. Sampling and Test Specimens
D123.
7.1 Primary Sampling Unit—Consider individual contain-
ers from each shipping carton to be the primary sampling units
This test method is under the jurisdiction ofASTM Committee D13 on Textiles
7.2 Laboratory Sampling Unit—As a laboratory sampling
and is the direct responsibility of Subcommittee D13.54
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.