ISO 10750:2015 describes a method intended to determine the attachment strength of the top and bottom stops of a slide fastener. The method is applicable to all types of slide fastener for footwear.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10750:2015 describes a method intended to determine the attachment strength of the top and bottom stops of a slide fastener. The method is applicable to all types of slide fastener for footwear.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10764:2016 describes a method intended to assess the lateral strength of a closed slide fastener for footwear. The method is applicable to all types of slide fastener.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 18403:2016 specifies a test method intended to determine the maximum lateral force applied to a slide fastener for footwear under which it will close without failure. The method is applicable to all types of slide fastener.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10734:2016 specifies a test method intended to assess the strength of slide fastener pullers for footwear. The method is applicable to all types of footwear slide fastener.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10751:2016 describes a method intended to determine the resistance of a slide fastener to repeated opening and closing. The method is applicable to all types of slide fastener with a teeth length greater than 80 mm.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies performance levels and test methods for the following characteristics of slide fasteners made from interlocking components mounted on tapes: strengths of puller attachment, closed-end, top stop, open-end slide fastener box, reciprocating mechanism, closed slide fastener when extended laterally, open-end attachment when extended laterally, slider locking device, and open-end slide fastener single stringer slider retention and slider resistance to torque.
NOTE    The tests specified in Annexes B to K have been specifically devised to permit their direct application to finished slide fasteners with a view to giving the user reasonable assurance that a slide fastener conforming to the requirements of this Standard can satisfactorily fulfil its intended purpose. Annex L gives information about sampling procedures for bulk quantities of slide fasteners.
In addition, performance levels are also specified for colour fastness to washing, dry cleaning and water, and for dimensional stability to washing and dry cleaning.
This European Standard is applicable to slide fasteners for general use and is not applicable to slide fasteners for specialist purposes ( for example: pressure sealed slide fasteners for diving suits).

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a test method intended to determine the maximum lateral force applied to a slide fastener for footwear under which it will close without failure.  The method is applicable to all types of slide fastener.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies a test method intended to assess the strength of slide fastener pullers for footwear.  The method is applicable to all types of footwear slide fastener.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard describes a method intended to determine the resistance of a slide fastener to repeated opening and closing.  The method is applicable to all types of slide fastener with a chain length greater than 80 mm

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard describes a method intended to assess the lateral strength of a closed slide fastener for footwear.  The method is applicable to all types of slide fastener.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies performance levels and test methods for the following characteristics
of slide fasteners made from interlocking components mounted on tapes: strengths of puller
attachment, closed-end, top stop, open-end slide fastener box, reciprocating mechanism, closed slide
fastener when extended laterally, open-end attachment when extended laterally, slider locking device,
and open-end slide fastener single stringer slider retention and slider resistance to torque.
NOTE The tests specified in Annexes B to K have been specifically devised to permit their direct application
to finished slide fasteners with a view to giving the user reasonable assurance that a slide fastener conforming to
the requirements of this standard can satisfactorily fulfil its intended purpose. Annex L gives information about
sampling procedures for bulk quantities of slide fasteners.
In addition, performance levels are also specified for colour fastness to washing, dry cleaning and water,
and for dimensional stability to washing and dry cleaning.
This European Standard is applicable to slide fasteners for general use and is not applicable to slide
fasteners for specialist purposes (for example: pressure sealed slide fasteners for diving suits).

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This test method is intended to determine the locking strength of a slide fastener slider for footwear.  The method is applicable to all types of slide fastener that have a slider locking device.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to assess the burst strength of a closed slide fastener for footwear.  The method is applicable to all types of slide fastener.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10748:2011 specifies a test method to determine the locking strength of a slide fastener slider for footwear. The method is applicable to all types of slide fastener that have a slider locking device.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10717:2010 specifies a test method intended to assess the burst strength of a closed slide fastener for footwear. The method is applicable to all types of slide fastener.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 10765:2010 specifies a test method for the determination of some typical parameters of elastics for footwear using the strength/elongation graph, which is obtained from the tensile strength test. This method is applicable to any elastic material used for footwear.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the resistance to fraying of touch and close fasteners.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the resistance to fraying of touch and close fasteners.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report describes different methods of integration of touch and close fasteners to the final or finished product, such as:
Sewing,
mechanical attachment,
adhesive pressure sensitive,
heat activated,
welded attachment,
moulding in,
straps,
non-continous application in various widths,
together with the appropriate test method.

  • Technical report
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report describes different methods of integration of touch and close fasteners to the final or finished product, such as:
Sewing,
mechanical attachment,
adhesive pressure sensitive,
heat activated,
welded attachment,
moulding in,
straps,
non-continous application in various widths,
together with the appropriate test method.

  • Technical report
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the longitudinal shear strength of a touch and close fastener.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the longitudinal shear strength of a touch and close fastener.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): UAP of 4 months (TC Res C 3/1998) (CC/980525)
2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for closing a touch and close fastener, prior to washing and drying or dry-cleaning.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the dimensional change in washing and drying or dry cleaning of touch and close fastener tapes.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Migrated from Progress Sheet (TC Comment) (2000-07-10): UAP of 4 months (TC Res C 3/1998) (CC/980525)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the peel strength of a touch and close fastener.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the dimensional change in washing and drying or dry cleaning of touch and close fastener tapes.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for closing a touch and close fastener, prior to washing and drying or dry-cleaning.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the peel strength of a touch and close fastener.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies a method for measuring the curvature of each of the male and female tapes making up a touch and close fastener.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard describes an apparatus and method of test for submitting touch and close fasteners to opening and closing cycles in order to simulate use. The touch and close fasteners subjected to these cycles will be used in subsequent physical tests intended to measure the residual mechanical strength characteristics.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the overall widths and effective widths of tape which comprise a touch and close fastener, and the effective width of the resulting closure.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies a method for measuring the resistance to slipping of the threads in a slit selvedge of a touch and close fastener tape.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for determining the overall widths and effective widths of tape which comprise a touch and close fastener, and the effective width of the resulting closure.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies a method for measuring the curvature of each of the male and female tapes making up a touch and close fastener.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard describes an apparatus and method of test for submitting touch and close fasteners to opening and closing cycles in order to simulate use. The touch and close fasteners subjected to these cycles will be used in subsequent physical tests intended to measure the residual mechanical strength characteristics.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies a method for measuring the resistance to slipping of the threads in a slit selvedge of a touch and close fastener tape.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to assess the lateral strength of a closed slide fastener.  The method is applicable to all types of slide fastener.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to assess the burst strength of a closed slide fastener for footwear. The method is applicable to all types of slide fastener.

  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This test method is intended to determine the maximum lateral force applied to a slide fastener for footwear under which it will close without failure.  The method is applicable to all types of slide fastener.

  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to determine the resistance of a slide fastener to repeated opening and closing.  The method is applicable to all types of slide fastener with a chain length greater than 80 mm.

  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to determine the attachment strength of the top and bottom stops of a slide fastener.  The method is applicable to all types of slide fastener for footwear.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to assess the burst strength of a closed slide fastener for footwear. The method is applicable to all types of slide fastener.

  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to assess the lateral strength of a closed slide fastener.  The method is applicable to all types of slide fastener.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to determine the resistance of a slide fastener to repeated opening and closing.  The method is applicable to all types of slide fastener with a chain length greater than 80 mm.

  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This method is intended to determine the attachment strength of the top and bottom stops of a slide fastener.  The method is applicable to all types of slide fastener for footwear.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This test method is intended to determine the maximum lateral force applied to a slide fastener for footwear under which it will close without failure.  The method is applicable to all types of slide fastener.

  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a standard method for determining the PM10 or PM2,5 mass concentrations of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.
Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h, over a nominal sampling period of 24 h. Measurement results are expressed in µg/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The range of application of this European Standard is from approximately 1 µg/m3 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty) up to 150 µg/m3 for PM10 and 120 µg/m3 for PM2,5.
NOTE 1   Although the European Standard is not validated for higher concentrations, its range of application could well be extended to ambient air concentrations up to circa 200 µg/m3 when using suitable filter materials (see 5.1.4).
This European Standard describes procedures and gives requirements for the use of so-called sequential samplers, equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout the European Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this European Standard does not exclude the use of single-filter samplers.
This European Standard does not give procedures for the demonstration of equivalence of other sampler types, e.g. equipped with a different aerosol classifier and/or operating at different flow rates. Such procedures and requirements are given in detail in the Guide to the Demonstration of Equivalence of Ambient Air Monitoring Methods [11] and for automated continuous PM monitors (see CEN/TS 16450:2013).
The present European Standard represents an evolution of earlier European Standards (EN 12341:1998 and EN 14907:2005) through the development of the 2,3 m3/h sampler to include constraints on the filter temperature during and after sampling and the ability to monitor temperatures at critical points in the sampling system. It is recommended that when equipment is procured it complies fully with the present European Standard. However, older versions of these 2,3 m3/h samplers that do not employ sheath air cooling, the ability to cool filters after sampling, or the ability to monitor temperatures at critical points in the sampling system have a special status in terms of their use as reference samplers. Historical results obtained using these samplers will remain valid. These samplers can still be used for monitoring purposes and for equivalence trials, provided that a well justified additional allowance is made to their uncertainties (see Annex B).
In addition, three specific sampling systems  - the -long nozzle - 2,3 m3/h sampler and the 68 m3/h sampler for PM10 in EN 12341:1998, and the 30 m3/h PM2,5 inlet in EN 14907:2005  - also have a special status in terms of their use as reference samplers. Historical results obtained using these samplers will remain valid. These samplers can still be used for monitoring purposes and for equivalence trials, provided that a well-justified additional allowance is made to their uncertainties (see Annex B).
Other sampling systems, as described in Annex B of this European Standard, can be used provided that a well justified additional allowance is made to their uncertainties as derived from equivalence tests.
NOTE 2   By evaluating existing data it has been shown that these samplers give results for PM10 and PM2,5 that are equivalent to those obtained by application of this European Standard. Results are shown in Annex B.
This European Standard also provides guidance for the selection and testing of filters with the aim of reducing the measurement uncertainty of the results obtained when applying this European Standard.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day