Standard Test Method for Nicotine and 3-Ethenylpyridine in Indoor Air

SCOPE
1.1 This test method covers the sampling/analysis of nicotine and 3-ethenylpyridine (3-EP) in indoor air. This test method is based upon the collection of nicotine and 3-EP by adsorption on a sorbent resin, extraction of nicotine and 3-EP from the sorbent resin, and determination by gas chromatography (GC) with nitrogen selective detection.  (1)
1.2 The active samplers consist of an XAD-4 sorbent tube attached to a sampling pump. This test method is applicable to personal or area sampling.
1.3 This test method is limited in sample duration by the capacity of the XAD-4 tube for nicotine (about 300 g). This test method has been evaluated up to 24-h sample duration; however, samples are typically acquired for  at least  1 h (sometimes  only  1 h). (2)
1.4 For this test method, limits of detection (LOD) and quantitation (LOQ) for nicotine at a sampling rate of 1.5 L/min are, respectively, 0.11 g/m3  and 0.37 g/m3  for 1-h sample duration and 0.01 g/m3  and 0.05 g/m3  for 8-h sample duration. The LOD and LOQ for 3-EP at a sampling rate of 1.5 L/min are, respectively, 0.06 g/m3  and 0.19 g/m3  for 1-h sample duration and 0.01 g/m3  and 0.02 g/m 3  for 8-h sample duration (2). Both LOD and LOQ can be reduced by increasing the sensitivity of the thermionic specific detector.
1.5 The values stated in SI units are to be regarded as standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary information is given in 13.6 .

General Information

Status
Historical
Publication Date
09-Mar-2001
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D5075-01 - Standard Test Method for Nicotine and 3-Ethenylpyridine in Indoor Air
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D5075–01
Standard Test Method for
1
Nicotine and 3-Ethenylpyridine in Indoor Air
This standard is issued under the fixed designation D5075; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
3
1.1 This test method covers the sampling/analysis of nico- 2.1 ASTM Standards:
tine and 3-ethenylpyridine (3-EP) in indoor air. This test D1356 Terminology Relating to Sampling andAnalysis of
method is based upon the collection of nicotine and 3-EP by Atmospheres
adsorption on a sorbent resin, extraction of nicotine and 3-EP D1357 Practice for Planning the Sampling of the Ambient
from the sorbent resin, and determination by gas chromatog- Atmosphere
2
raphy (GC) with nitrogen selective detection. (1) D3631 Test Methods for Measuring Surface Atmospheric
1.2 The active samplers consist of an XAD-4 sorbent tube Pressure
attached to a sampling pump.This test method is applicable to D5337 Practice for Flow Rate for Calibration of Personal
personal or area sampling. Sampling Pumps
1.3 This test method is limited in sample duration by the E260 Practice for Packed Column Gas Chromatography
capacity of the XAD-4 tube for nicotine (about 300 µg). This E355 Practice for Gas Chromatography Terms and Rela-
test method has been evaluated up to 24-h sample duration; tionships
however, samples are typically acquired for at least 1h
3. Terminology
(sometimes only 1 h). (2)
1.4 For this test method, limits of detection (LOD) and 3.1 Definitions—For definitions of terms used in this test
method, refer to Terminology D1356 and Practice E355.
quantitation(LOQ)fornicotineatasamplingrateof1.5L/min
3 3
are, respectively, 0.11 µg/m and 0.37 µg/m for 1-h sample 3.2 Definitions of Terms Specific to This Standard:
3 3
3.2.1 environmental tobacco smoke (ETS)—an aged, dilute
duration and 0.01 µg/m and 0.05 µg/m for 8-h sample
duration.TheLODandLOQfor3-EPatasamplingrateof1.5 composite of exhaled tobacco smoke and smoke from tobacco
3 3
products.
L/min are, respectively, 0.06 µg/m and 0.19 µg/m for 1-h
3 3
3.2.2 nitrogen-phosphorus detector (NPD)—a highly sensi-
sampledurationand0.01µg/m and0.02µg/m for8-hsample
duration (2).BothLODandLOQcanbereducedbyincreasing tivedeviceselectivefordetectionofnitrogen-andphosphorus-
containing organic compounds.
the sensitivity of the thermionic specific detector.
1.5 The values stated in SI units are to be regarded as 3.2.3 XAD-4 resin—macroreticular polystyrene-
divinylbenzene copolymer beads.
standard.
1.6 This standard does not purport to address all of the
4. Summary of Test Method
safety concerns, if any, associated with its use. It is the
4.1 A known volume of air is drawn through a sorbent
responsibility of the user of this standard to establish appro-
sampling tube containing XAD-4 resin to adsorb the nicotine
priate safety and health practices and determine the applica-
and 3-EP present.
bility of regulatory limitations prior to use. Specific precau-
4.2 The XAD-4 sorbent tube contents are transferred to a
tionary information is given in 13.6.
2-mLautosamplervial,andthenicotineand3-EParedesorbed
with ethyl acetate containing 0.01% triethylamine and a
1
known quantity of quinoline, the internal standard.
This test method is under the jurisdiction of ASTM Committee D22 on
Sampling andAnalysis ofAtmospheres and is the direct responsibility of Subcom-
mittee D22.05 on Indoor Air.
3
Current edition approved March 10, 2001. Published May 2001. Originally For referenced ASTM standards, visit the ASTM website, www.astm.org, or
{1
published as D5075–90. Last previous edition D5075–96 . contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
2
The boldface numbers in parentheses refer to a list of references at the end of Standards volume information, refer to the standard’s Document Summary page on
the text. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D5075–01
4.3 An aliquot of the desorbed sample is injected into a gas (6,10,11,12). 3-Ethenylpyridine concentrations typically are
chromatograph equipped with a thermionic-specific (nitrogen- about one third the concentrations of nicotine in real-world
phosphorus) detector. environments (13).
4.4 The areas of the resulting nicotine and 3-EP peaks are
6. Interferences
each divided by the area of the internal standard peak and
6.1 UseofpackedGCcolumnsmayresultinreadingslower
compared with area ratios obtained from the injection of
than expected because nicotine
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.