ASTM D4262-05(2018)
(Test Method)Standard Test Method for pH of Chemically Cleaned or Etched Concrete Surfaces
Standard Test Method for pH of Chemically Cleaned or Etched Concrete Surfaces
SIGNIFICANCE AND USE
3.1 Chemical cleaning and etching is used to prepare concrete for coating.
3.2 Residual chemicals not removed by water rinsing may adversely affect the performance and adhesion of coatings applied over prepared concrete surfaces. It is the intent of this test method to determine that residual chemicals have been removed by measuring the acidity or alkalinity of the final rinsed surface.
SCOPE
1.1 This test method covers procedures for determining the acidity or alkalinity of concrete surfaces prepared by chemical cleaning or etching prior to coating.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D4262 − 05 (Reapproved 2018)
Standard Test Method for
pH of Chemically Cleaned or Etched Concrete Surfaces
This standard is issued under the fixed designation D4262; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope test method to determine that residual chemicals have been
removed by measuring the acidity or alkalinity of the final
1.1 This test method covers procedures for determining the
rinsed surface.
acidity or alkalinity of concrete surfaces prepared by chemical
cleaning or etching prior to coating.
4. Apparatus
1.2 This standard does not purport to address all of the
4.1 The specific apparatus for each test is described in
safety concerns, if any, associated with its use. It is the
Annex A1 – Annex A3.
responsibility of the user of this standard to establish appro-
priate safety, health, and environmental practices and deter-
5. Materials
mine the applicability of regulatory limitations prior to use.
5.1 Potable Water, for rinsing chemically cleaned or etched
1.3 This international standard was developed in accor-
concrete surfaces.
dance with internationally recognized principles on standard-
5.2 Wet Concrete Surface, following the final water rinse
ization established in the Decision on Principles for the
and before the rinse water has completely drained off the
Development of International Standards, Guides and Recom-
surface.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
6. Procedure
2. Terminology
6.1 The preparatory actions for each alternative are de-
scribed in Annex A1 – Annex A3.
2.1 Definitions:
2.1.1 pH, n—a measure of acidity or alkalinity of a solution
6.2 At least two surface pH readings shall be taken for each
or surface, with neutrality represented by a value of 7, with
500 square feet or portion thereof. Readings shall be taken at
increasing acidity represented by smaller values, and with
randomly selected locations immediately following the final
increasing alkalinity represented by increasing values.
rinse and before all the rinse water has drained off the surface.
6.3 The pH of the water used for rinsing shall be determined
3. Significance and Use
to establish acceptance criteria. Readings shall be taken at the
3.1 Chemical cleaning and etching is used to prepare
beginning and end of the final rinse.
concrete for coating.
6.4 Unless otherwise specified, tests shall be conducted in
3.2 Residual chemicals not removed by water rinsing may
accordance with this procedure.
adversely affect the performance and adhesion of coatings
applied over prepared concrete surfaces. It is the intent of this 7. Acceptance Criteria
7.1 The pH readings following the final rinse shall not be
more than 1.0 pH lower or 2.0 higher than the pH of the rinse
This test method is under the jurisdiction of ASTM Committee D33 on
ProtectiveCoatingandLiningWorkforPowerGener
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.