Standard Specification for Slag Cement for Use in Concrete and Mortars

ABSTRACT
This specification covers three strength grades of finely ground granulated blast-furnace slag (Grades 80, 100, and 120) for use as a cementitious material in concrete and mortars. The slag shall contain no additions and shall conform to the sulfide sulfur and sulfate chemical composition requirement. Physical properties of the slag shall be in accordance with the requirements for fineness as determined by air permeability and air content, slag activity index, and compressive strength.
SCOPE
1.1 This specification covers slag cement for use as a cementitious material in concrete and mortar.  
Note 1: The material described in this specification may be used to produce a blended cement meeting the requirements of Specification C595/C595M or as a separate ingredient in concrete or mortar mixtures. The material may also be useful in a variety of special grouts and mortars, and when used with an appropriate activator, as the principal cementitious material in some applications.
Note 2: Information on technical aspects of the use of the material described in this specification is contained in Appendix X1, Appendix X2, and Appendix X3. More detailed information on that subject is contained in ACI 233R.2  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.  
1.3 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes (excluding those in tables) shall not be considered as requirements of this standard.  
1.4 The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Jan-2024
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C989/C989M-24 - Standard Specification for Slag Cement for Use in Concrete and Mortars
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C989/C989M-24 - Standard Specification for Slag Cement for Use in Concrete and Mortars
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: C989/C989M − 24
Standard Specification for
1
Slag Cement for Use in Concrete and Mortars
This standard is issued under the fixed designation C989/C989M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
1.1 This specification covers slag cement for use as a
cementitious material in concrete and mortar.
2. Referenced Documents
NOTE 1—The material described in this specification may be used to 3
2.1 ASTM Standards:
produce a blended cement meeting the requirements of Specification
C109/C109M Test Method for Compressive Strength of
C595/C595M or as a separate ingredient in concrete or mortar mixtures.
Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube
The material may also be useful in a variety of special grouts and mortars,
and when used with an appropriate activator, as the principal cementitious Specimens)
material in some applications.
C114 Test Methods for Chemical Analysis of Hydraulic
NOTE 2—Information on technical aspects of the use of the material
Cement
described in this specification is contained in Appendix X1, Appendix X2,
C125 Terminology Relating to Concrete and Concrete Ag-
and Appendix X3. More detailed information on that subject is contained
2
gregates
in ACI 233R.
C150/C150M Specification for Portland Cement
1.2 The values stated in either SI units or inch-pound units
C185 Test Method for Air Content of Hydraulic Cement
are to be regarded separately as standard. The values stated in
Mortar
each system are not necessarily exact equivalents; therefore, to
C188 Test Method for Density of Hydraulic Cement
ensure conformance with the standard, each system shall be
C204 Test Methods for Fineness of Hydraulic Cement by
used independently of the other, and values from the two
Air-Permeability Apparatus
systems shall not be combined.
C430 Test Method for Fineness of Hydraulic Cement by the
1.3 The text of this standard references notes and footnotes
45-μm (No. 325) Sieve
that provide explanatory information. These notes and foot-
C465 Specification for Processing Additions for Use in the
notes (excluding those in tables) shall not be considered as
Manufacture of Hydraulic Cements
requirements of this standard.
C595/C595M Specification for Blended Hydraulic Cements
1.4 The following safety hazards caveat pertains only to the C670 Practice for Preparing Precision and Bias Statements
test methods described in this specification. This standard does for Test Methods for Construction Materials
not purport to address all of the safety concerns, if any, C1012/C1012M Test Method for Length Change of
associated with its use. It is the responsibility of the user of this Hydraulic-Cement Mortars Exposed to a Sulfate Solution
standard to establish appropriate safety, health, and environ- C1038/C1038M Test Method for Expansion of Hydraulic
mental practices and determine the applicability of regulatory Cement Mortar Bars Stored in Water
limitations prior to use. C1437 Test Method for Flow of Hydraulic Cement Mortar
1.5 This international standard was developed in accor- C1778 Guide for Reducing the Risk of Deleterious Alkali-
dance with internationally recognized principles on standard- Aggregate Reaction in Concrete
ization established in the Decision on Principles for the D3665 Practice for Random Sampling of Construction Ma-
Development of International Standards, Guides and Recom- terials
3. Terminology
1
This specification is under the jurisdiction of ASTM Committee C09 on
3.1 Definitions—For definitions of terms used in this
Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee
specification, refer to Terminology C125.
C09.27 on Slag Cement.
Current edition approved Feb. 1, 2024. Published March 2024. Originally
approved in 1982. Last previous edition approved in 2022 as C989/C989M – 22.
3
DOI: 10.1520/C0989_C0989M-24. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
2
ACI 233R Guide to the Use of Slag Cement in Concrete and Mortar. Available contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI Standards volume information, refer to the standard’s Document Summary page on
48333-9094, http://www.concrete.org. th
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C989/C989M − 22 C989/C989M − 24
Standard Specification for
1
Slag Cement for Use in Concrete and Mortars
This standard is issued under the fixed designation C989/C989M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers slag cement for use as a cementitious material in concrete and mortar.
NOTE 1—The material described in this specification may be used for blending with portland cement to produce a blended cement meeting the
requirements of Specification C595/C595M or as a separate ingredient in concrete or mortar mixtures. The material may also be useful in a variety of
special grouts and mortars, and when used with an appropriate activator, as the principal cementitious material in some applications.
NOTE 2—Information on technical aspects of the use of the material described in this specification is contained in Appendix X1, Appendix X2, and
2
Appendix X3. More detailed information on that subject is contained in ACI 233R.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the
inch-pound units are shown in brackets. The values stated in each system may not beare not necessarily exact equivalents;
therefore, to ensure conformance with the standard, each system shall be used independently of the other. Combiningother, and
values from the two systems may result in non-conformance with the standard. Values are stated in only SI units when inch-pound
units are not used in practice.shall not be combined.
1.3 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes
(excluding those in tables) shall not be considered as requirements of this standard.
1.4 The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not
purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior
to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
3
2.1 ASTM Standards:
1
This specification is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.27 on
Slag Cement.
Current edition approved July 1, 2022Feb. 1, 2024. Published August 2022March 2024. Originally approved in 1982. Last previous edition approved in 20182022 as
C989/C989M – 18a. DOI: 10.1520/C0989_C0989M-22.22. DOI: 10.1520/C0989_C0989M-24.
2
ACI 233R Guide to the Use of Slag Cement in Concrete and Mortar. Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI
48333-9094, http://www.concrete.org.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C989/C989M − 24
C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube Specimens)
C114 Test Methods for Chemical Analysis of Hydraulic Cement
C125 Terminology Relating to Concrete and Concrete Aggregates
C150/C150M Specification for Portland Cement
C185 Test Method for Air Content of Hydraulic Cement Mortar
C188 Test Method for Density of Hydraulic Cement
C204 Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
C430 Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
C465 Specification for Processing Ad
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.