Standard Test Method for Determining a Measured Nameplate Recovery Rate of Stationary Oil Skimmer Systems

SIGNIFICANCE AND USE
4.1 It has been industry practice to claim the capacity of a skimmer based on the rate of the discharge pump (which are typically rated using water as a test fluid) or other arbitrary methods.  
4.2 End users need a test methodology that evaluates optimum performance data for planning and selection of equipment.  
4.3 This test method will assist producers and other stakeholders to verify and accurately report skimmer system performance.  
4.4 This test method is specifically designed to quantify two key skimmer performance values, to reduce testing costs, and to encourage industry wide performance standardization.  
4.5 This test method establishes test conditions that will result in a measured nameplate recovery rate and an indication of the combination of test parameters (oil type, viscosity, operating speed) that result in the highest average performance for the tested skimmer system.  
4.6 This test method will validate the performance of the discharge pump in the skimmer system, under conditions that are typical of a recovery operation. Specifically, this will include a modest imposed head pressure composed of static head and dynamic friction losses due to a specified length of discharge hose.  
4.7 This test method encourages performance testing using two or more oils for comparison purposes.  
4.8 Tests shall be conducted under well-documented conditions and generate repeatable results. More detailed testing and collection of skimmer performance is covered under existing standards (for example, Guide F631).  
4.9 Testing (SL Ross 2007)3 has shown that, when water is present, recovery performance in slick thicknesses ranging from 50 mm to 75 mm results in values comparable to significantly thicker slicks. This may not be the case with high-rate skimmers in viscous oil, where the rate of oil recovery exceeds the rate at which the slick will flow to the skimmer mechanism.  
4.10 For skimming systems that include various options for the discharge pump, ...
SCOPE
1.1 This test method defines a method and measurement criteria to quantify the performance of a stationary skimmer in ideal conditions in support of a device’s nameplate recovery rate (capacity). If a determination of a skimmer’s capabilities in realistic conditions (that is, advancing or waves) is required, testing should be performed according to Guide F631 or equivalent.  
1.2 This test method includes the option of testing to determine recovery efficiency.  
1.3 This test method and parameters are intended to provide ideal recovery conditions allowing the skimmer system to operate and collect oil at its maximum possible recovery rate. Given ideal conditions, inherent mechanical and physical attributes of the system become the limiting factors.  
1.4 This test method is intended to identify limitations of the skimmer system, such as performance of the skimming mechanism, the flow of oil within the skimmer and sump, the pump characteristics, and typical discharge head conditions.  
1.5 It is accepted that the measured nameplate recovery rate as determined by this test method will not likely be achievable under actual conditions of a spill. The measured nameplate recovery rate should be used in conjunction with a de-rating factor to account for such issues as changing encounter rate, changes in other recovery conditions, changes in oil properties and slick thickness, number of daylight hours, operator downtime, less than ideal control of skimmer settings, and inclement weather.  
1.6 This test method involves the use of specific test oils that may be considered hazardous materials. It is the responsibility of the user of this test method to procure and abide by necessary permits and regulations for the use and disposal of test oil.  
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.8 This standard does not purport to address all of ...

General Information

Status
Historical
Publication Date
30-Jun-2015
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F2709-15 - Standard Test Method for Determining a Measured Nameplate Recovery Rate of Stationary Oil Skimmer Systems
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F2709-15 - Standard Test Method for Determining a Measured Nameplate Recovery Rate of Stationary Oil Skimmer Systems
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F2709 − 15
Standard Test Method for
Determining a Measured Nameplate Recovery Rate of
1
Stationary Oil Skimmer Systems
This standard is issued under the fixed designation F2709; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.7 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
1.1 This test method defines a method and measurement
standard.
criteria to quantify the performance of a stationary skimmer in
1.8 This standard does not purport to address all of the
ideal conditions in support of a device’s nameplate recovery
safety concerns, if any, associated with its use. It is the
rate(capacity).Ifadeterminationofaskimmer’scapabilitiesin
responsibility of the user of this standard to establish appro-
realistic conditions (that is, advancing or waves) is required,
priate safety and health practices and determine the applica-
testing should be performed according to Guide F631 or
bility of regulatory limitations prior to use.
equivalent.
1.2 This test method includes the option of testing to
2. Referenced Documents
determine recovery efficiency.
2
2.1 ASTM Standards:
1.3 This test method and parameters are intended to provide
D971 Test Method for Interfacial Tension of Oil Against
ideal recovery conditions allowing the skimmer system to
Water by the Ring Method
operate and collect oil at its maximum possible recovery rate.
D1298 Test Method for Density, Relative Density, or API
Given ideal conditions, inherent mechanical and physical
Gravity of Crude Petroleum and Liquid Petroleum Prod-
attributes of the system become the limiting factors.
ucts by Hydrometer Method
1.4 Thistestmethodisintendedtoidentifylimitationsofthe D2983 Test Method for Low-Temperature Viscosity of Lu-
skimmer system, such as performance of the skimming bricants Measured by Brookfield Viscometer
mechanism, the flow of oil within the skimmer and sump, the D4007 Test Method forWater and Sediment in Crude Oil by
pump characteristics, and typical discharge head conditions. the Centrifuge Method (Laboratory Procedure)
F631 Guide for Collecting Skimmer Performance Data in
1.5 It is accepted that the measured nameplate recovery rate
Controlled Environments
as determined by this test method will not likely be achievable
under actual conditions of a spill. The measured nameplate
3. Terminology
recovery rate should be used in conjunction with a de-rating
factor to account for such issues as changing encounter rate, 3.1 Definitions:
changes in other recovery conditions, changes in oil properties 3.1.1 fluid recovery rate—the volume of fluid recovered by
3
and slick thickness, number of daylight hours, operator the device per unit of time (m /h).
downtime, less than ideal control of skimmer settings, and
3.1.2 ideal conditions—operating conditions that result in
inclement weather.
the maximum nameplate recovery rate of a skimming system
within the limitations of the test method.
1.6 This test method involves the use of specific test oils
that may be considered hazardous materials. It is the respon-
3.1.3 measured nameplate recovery rate—the maximum
sibility of the user of this test method to procure and abide by
rate at which the skimmer system can recover and process oil
necessary permits and regulations for the use and disposal of
under ideal conditions.
test oil.
3.1.4 nameplate recovery rate—the maximum skimming
capacity of a device as stated by the manufacturer.
1
This test method is under the jurisdiction of ASTM Committee F20 on
Hazardous Substances and Oil Spill Response and is the direct responsibility of
2
Subcommittee F20.12 on Removal. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved July 1, 2015. Published November 2015. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2008. Last previous edition approved in 2008 as F2709–08. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F2709-15. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2709 − 15
3.1.5 oleophilic—oil skimmers that use collection surfaces 4.10 For skimming systems that include various options for
for recovery, for example, disc, brush, drum, belt, mop, and so the discharge pump, the test described in this test method may
forth. be used to measure the performance of the skimming compo-
nent of the system. Performa
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2709 − 08 F2709 − 15
Standard Test Method for
Determining a Measured Nameplate Recovery Rate of
1
Stationary Oil Skimmer Systems
This standard is issued under the fixed designation F2709; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method defines a method and measurement criteria to quantify the nameplate recovery rate (capacity) performance
of a stationary skimmer system in ideal conditions. in ideal conditions in support of a device’s nameplate recovery rate (capacity).
If a determination of a skimmer’s capabilities in realistic conditions (that is, advancing or waves) is required, testing should be
performed according to Guide F631 or equivalent.
1.2 This test method includes the option of testing to determine recovery efficiency.
1.3 This test method and parameters are intended to provide ideal recovery conditions allowing the skimmer system to operate
and collect oil at its maximum possible recovery rate. Given ideal conditions, inherent mechanical and physical attributes of the
system become the limiting factors.
1.4 This test method is intended to identify limitations of the skimmer system, such as performance of the skimming
mechanism, the flow of oil within the skimmer and sump, the pump characteristics, and typical discharge head conditions.
1.5 It is accepted that the measured nameplate recovery rate as determined by this test method will not likely be achievable
under actual conditions of a spill. The measured nameplate recovery rate should be used in conjunction with a de-rating factor to
account for such issues as changing encounter rate, changes in other recovery conditions, changes in oil properties and slick
thickness, number of daylight hours, operator downtime, less than ideal control of skimmer settings, and inclement weather.
1.6 This test method involves the use of specific test oils that may be considered hazardous materials. It is the responsibility
of the user of this test method to procure and abide by necessary permits and regulations for the use and disposal of test oil.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D971 Test Method for Interfacial Tension of Oil Against Water by the Ring Method
D1298 Test Method for Density, Relative Density, or API Gravity of Crude Petroleum and Liquid Petroleum Products by
Hydrometer Method
D2983 Test Method for Low-Temperature Viscosity of Lubricants Measured by Brookfield Viscometer
D4007 Test Method for Water and Sediment in Crude Oil by the Centrifuge Method (Laboratory Procedure)
F631 Guide for Collecting Skimmer Performance Data in Controlled Environments
3. Terminology
3.1 Definitions:
3
3.1.1 fluid recovery rate—the volume of fluid recovered by the device per unit of time (m /h).
1
This test method is under the jurisdiction of ASTM Committee F20 on Hazardous Substances and Oil Spill Response and is the direct responsibility of Subcommittee
F20.12 on Removal.
Current edition approved Sept. 15, 2008July 1, 2015. Published September 2008November 2015. Originally approved in 2008. Last previous edition approved in 2008
as F2709–08. DOI: 10.1520/F2709-08.10.1520/F2709-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2709 − 15
3.1.2 ideal conditions—operating conditions that result in the maximum nameplate recovery rate of a skimming system within
the limitations of the test method.
3.1.3 measured nameplate recovery rate—the maximum rate at which the skimmer system can recover and process oil under
ideal conditions.
3.1.4 nameplate recovery rate—the
...