Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures

SIGNIFICANCE AND USE
4.1 This practice is useful as a reference by an owner and/or the engineer in preparing project specifications.  
4.2 The practice is useful as a reference by an owner, engineer, or installing contractor to properly install precast concrete circular manholes.
SCOPE
1.1 This practice covers the procedures to be followed in the planning, site preparation, installation, testing and backfilling of underground vertical reinforced circular precast concrete manholes and components manufactured in accordance with Specification C478 (C478M) and used in sewer, drainage, and water works.  
1.2 Concrete pipe and box culverts are not covered under this practice. Also, precast concrete utility structures covered in Specification C858 are excluded from this practice.  
1.3 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Feb-2016
Technical Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM C1821/C1821M-16 - Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1821/C1821M − 16
Standard Practice for
Installation of Underground Circular Precast Concrete
1
Manhole Structures
This standard is issued under the fixed designation C1821/C1821M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C822 Terminology Relating to Concrete Pipe and Related
Products
1.1 Thispracticecoverstheprocedurestobefollowedinthe
C858 Specification for Underground Precast Concrete Util-
planning, site preparation, installation, testing and backfilling
ity Structures
of underground vertical reinforced circular precast concrete
C881/C881M Specification for Epoxy-Resin-Base Bonding
manholes and components manufactured in accordance with
Systems for Concrete
Specification C478 (C478M) and used in sewer, drainage, and
C923 Specification for Resilient Connectors Between Rein-
water works.
forced Concrete Manhole Structures, Pipes, and Laterals
1.2 Concrete pipe and box culverts are not covered under
C923M Specification for Resilient Connectors Between Re-
thispractice.Also,precastconcreteutilitystructurescoveredin
inforced Concrete Manhole Structures, Pipes, and Laterals
Specification C858 are excluded from this practice.
(Metric)
1.3 Units—The values stated in either SI units or inch-
C928/C928M Specification for Packaged, Dry, Rapid-
pound units are to be regarded separately as standard. The
Hardening Cementitious Materials for Concrete Repairs
values stated in each system may not be exact equivalents;
C969 Practice for Infiltration and Exfiltration Acceptance
therefore,eachsystemshallbeusedindependentlyoftheother.
Testing of Installed Precast Concrete Pipe Sewer Lines
Combining values from the two systems may result in non-
C969M Practice for Infiltration and Exfiltration Acceptance
conformance with the standard.
Testing of Installed Precast Concrete Pipe Sewer Lines
1.4 This standard does not purport to address all of the
(Metric)
safety concerns, if any, associated with its use. It is the
C990 Specification for Joints for Concrete Pipe, Manholes,
responsibility of the user of this standard to establish appro-
and Precast Box Sections Using Preformed Flexible Joint
priate safety and health practices and determine the applica-
Sealants
bility of regulatory limitations prior to use.
C990M Specification for Joints for Concrete Pipe,
Manholes, and Precast Box Sections Using Preformed
2. Referenced Documents
2 Flexible Joint Sealants (Metric)
2.1 ASTM Standards:
C1107/C1107M Specification for Packaged Dry, Hydraulic-
C443 Specification for Joints for Concrete Pipe and
Cement Grout (Nonshrink)
Manholes, Using Rubber Gaskets
C1244 Test Method for Concrete Sewer Manholes by the
C443M Specification for Joints for Concrete Pipe and
Negative Air Pressure (Vacuum) Test Prior to Backfill
Manholes, Using Rubber Gaskets (Metric)
C1244M Test Method for Concrete Sewer Manholes by the
C478 Specification for Circular Precast Reinforced Concrete
Negative Air Pressure (Vacuum) Test Prior to Backfill
Manhole Sections
(Metric)
C478M Specification for Circular Precast Reinforced Con-
C1478 Specification for Storm Drain Resilient Connectors
crete Manhole Sections (Metric)
Between Reinforced Concrete Storm Sewer Structures,
Pipes, and Laterals
1
This test method is under the jurisdiction of ASTM Committee C13 on C1478M Specification for Storm Drain Resilient Connectors
Concrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholes
Between Reinforced Concrete Storm Sewer Structures,
and Specials.
Pipes, and Laterals (Metric)
Current edition approved Feb. 15, 2016. Published March 2016. DOI: 10.1520/
C1821_C1821M–16 D2487 Practice for Classification of Soils for Engineering
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Purposes (Unified Soil Classification System)
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
D2488 Practice for Description and Identification of Soils
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. (Visual-Manual Procedure)
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1821/C1821M − 16
F2510/F2510M Specification for Resilient Connectors Be- sloping or both may be planned in advance of the excavation
tween Reinforced Concrete Manhole Structures and Cor- work that will affect the installation of the manhole structure.
rugated High Density Polyethylene Drainage Pipes
6. Planning
2.2 AASHTO Standard:
AASHTO M145 Classification of Soils and Soil-Aggregate
6.1
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.