ASTM F2681-08(2014)
(Specification)Standard Specification for Body Protectors Used in Equine Racing
Standard Specification for Body Protectors Used in Equine Racing
SCOPE
1.1 This specification covers minimum performance criteria and describes test methods for body protectors for use in equine racing in a controlled environment.
Note 1: It is recognized that it is not possible to write a body protector performance standard that will result in products that can protect against all types of injury or death in an accident.
1.2 It is not the intention of this specification to bar from consideration materials of improved quality or performance not known at time of development of this specification.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F2681 −08 (Reapproved 2014) An American National Standard
Standard Specification for
Body Protectors Used in Equine Racing
This standard is issued under the fixed designation F2681; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
Equineracingisasportwithintrinsichazards.Itisrecognizedthatseriousinjuryordeathcanresult
from both low-energy and high-energy impacts, even when body protectors are worn. It is also
recognized that body protection must be acceptable for the sport, the user, and to the regulating
associations or agencies requiring their use. This specification has been developed with an emphasis
onprovidingcomfortable,nonrestrictiveimpactprotectioninalowerweightgarment.Injurieswillnot
be prevented by protective padding in accidents involving severe torsion, flexion or crushing of the
body. Acknowledging these limitations, this specification was developed using resources in the
medical, scientific, engineering, human factors, and biomedical fields, as well as resources from
equine competitors and professional Standardbred drivers and Thoroughbred jockeys. This specifi-
cation draws from work done by others where appropriate for this specification, and these standards
may be referenced. It should be noted that this specification specifies a laboratory test of a completed
body protector’s ability to reduce impacts.
1. Scope 2. Referenced Documents
1.1 This specification covers minimum performance criteria 2.1 ASTM Standards:
and describes test methods for body protectors for use in F1446 Test Methods for Equipment and Procedures Used in
equine racing in a controlled environment. Evaluating the Performance Characteristics of Protective
Headgear
NOTE 1—It is recognized that it is not possible to write a body protector
2.2 BSI Standards:
performance standard that will result in products that can protect against
all types of injury or death in an accident. EN 13158:2000 Protective clothing – protective jackets,
body and shoulder protectors for horse riders – Require-
1.2 It is not the intention of this specification to bar from
ments and test methods
considerationmaterialsofimprovedqualityorperformancenot
2.3 SAE Standards
known at time of development of this specification.
SAE J211 Recommended Practice for Instrumentation for
1.3 The values stated in SI units are to be regarded as
Impact Tests – Requirements for Channel Class 1000
standard. No other units of measurement are included in this
standard.
3. Terminology
1.4 This standard does not purport to address all of the
3.1 Definitions of Terms Specific to This Standard:
safety concerns, if any, associated with its use. It is the
3.1.1 In addition to terms defined in Test Methods F1446,
responsibility of the user of this standard to establish appro-
the following terms are specific to this specification.
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
This specification is under the jurisdiction ofASTM Committee F08 on Sports Standards volume information, refer to the standard’s Document Summary page on
Equipment, Playing Surfaces, and Facilities and is the direct responsibility of the ASTM website.
Subcommittee F08.55 on Body Padding. Available from British Standards Institute (BSI), 389 Chiswick High Rd.,
Current edition approved June 1, 2014. Published September 2014. Originally London W4 4AL, U.K., http://www.bsi-global.com.
approved in 2008. Last previous edition approved in 2008 as F2681 – 08. DOI: Available from Society of Automotive Engineers (SAE), 400 Commonwealth
10.1520/F2681-08R14. Dr., Warrendale, PA 15096-0001, http://www.sae.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2681−08 (2014)
FIG. 1Dimensional Coverage Requirements
3.1.2 body protector, n—sleeveless garment covering de- These materials shall not undergo significant loss of strength,
fined areas of the torso and lower back and consisting of one or flexibility, or other physical change as a result of contact with
more layers of material and designed to reduce trauma from perspiration or body oil.Any material used in the construction
impacts and falls. of body protectors shall not be adversely affected by ordinary
household soap and water, mild household detergent, or
3.1.3 calibration impact surface, n—flat modular elastomer
cleaners recommended by the manufacturer.
programmer (MEP), as specified in Test Methods F1446.
4.1.3 Adhesive materials used to attach padding or straps to
3.1.4 equine racing, n—any event or activity on a flat dirt,
the body protector shall be of a formulation that will not alter
grass, or synthetic surface track that emphasizes the horse’s
thechemicalorphysicalpropertiesofthematerialstoanextent
and rider’s or driver’s ability to complete a designated distance
as to reduce their protective qualities.
or course in as short a time as possible (for example,
4.1.4 The manufacturer of the body protector shall provide
Standardbred, Thoroughbred, and Quarter Horse racing).
written documentation to the testing laboratory indicating that
3.1.5 impact surface, n—flat anvil, as specified in the
the materials used in the body protector fulfill the requirements
Apparatus section of Test Methods F1446, used as the impact
of 4.1.1 – 4.1.3.
surface for the shock attenuation test (see 7.2).
4.2 Body Protector Assembly:
3.1.6 padding, n—any material or structure designed to
4.2.1 Any optional devices provided by the manufacturer of
absorb or distribute, or both, impact energy.
the body protector and fitted to the body protector shall be so
3.1.7 spherical impactor, n—sphericalimpactor,asspecified
designed that they are unlikely to cause any injury to the
in Test Methods F1446, used for the impact attenuation system
wearer or other participants during contact. If the manufacturer
check (see 10.1) and impact test procedures (see 11.2).
provides optional devices then the body protector shall be
tested with the optional devices fitted to the body protector.
4. Materials and Manufacture
4.2.2 Any unfaired projection extending more than 7 mm
4.1 Materials:
from the body protector outer surface shall break away or
4.1.1 All materials used in the fabrication of the body
collapse when impacted with forces equivalent to those pro-
protector shall be known as suitable for the intended applica-
duced by the impact tests described in 11.2 of this specifica-
tion.All padding materials used in the body protector shall not
tion. There shall be no fixture on the inner surface of the body
permanently distort during an exposure of at least4htoany
protector projecting more than 2 mm from the inner surface of
temperature in the range from -15 62to40 6 2°C, nor shall
the body protector toward the wearer’s body.
the material be significantly affected by exposure to ultraviolet
radiation, water, dirt, or vibration. 4.3 Extent and Form of Padding—The coverage of the body
4.1.2 Materials coming into contact with the wearer’s skin protectorlistedinSection6shallbecapableofbeingevaluated
shall not be a type known to cause skin irritation or diseases. according to 11.2 and shall meet the impact requirements of
F2681−08 (2014)
FIG. 2Armhole Circumference Measurement Device
Section 5. The extent of coverage shall include at least all of 6.3 Dimensioning—Body protectors shall have dimensions
the designated areas shown in Fig. 1. as shown in Fig. 1. DimensionAshall be the mid-value of the
range of the chest circumference, in centimetres, that the
NOTE 2—The body protector may have reduced padding thickness over
manufacturer states the body protector will fit. Dimension B
the shoulder, and it does not require padding in areas outside the test area
shall be reported in centimetres and defined by the following
defined in Fig. 1.
equation:
4.4 Attachments—The components of the fasteners for se-
B 5 20.011 A 12.66A 2 65.56 (1)
curing attachments to the body protector shall not reduce the ~ !
which represents the mathematically calculated anthropomet-
impact attenuation properties of the body protector.
ric mean for the waist to waist over the shoulder length for
chest sizes of 53 to 122 cm.
5. Performance Requirements
6.3.1 Four vertical reference lines, as defined in EN
5.1 General—Body protectors shall be capable of meeting
13158:2000, are to be used: C and C’ separated by 25% of
the requirements in this specification throughout their full
Dimension A on the chest, and D and D’ separated by 25% of
range of adjustment.
Dimension A on the back.
5.2 When tested in accordance with 11.1, the force to
6.3.2 The padding shall extend for more than 30% of
separate any closures shall not be less than 50 N. This
Dimension B along the lines C and C’ (C in Fig. 1).
requirement shall be met at ambient temperature 21 6 3°C and
6.3.3 The padding shall extend for more than 45% of
at a relative humidity of 50 6 15 %.
Dimension B along the lines D and D’ (D in Fig. 1).
5.3 The velocity of any test impact shall be 3.15 m/s 6 2%.
6.3.4 Thepaddingshallextendforalengthgreaterthan25%
The peak acceleration of any test impact shall not exceed
of Dimension B in the center front (E in Fig. 1).
300 g, when conditioned as described in 9.1 and when tested in
6.3.5 The armhole circumference shall be measured by
accordance with 11.2.
placing the armhole opening over the test device shown in Fig.
2. The point at which the armhole opening circumference
6. Dimensioning, Sizing and Body Coverage
contacts the cone measurement device at all points around the
6.1 The whole circumference of the torso shall be covered
circumference of the armhole shall be considered to be the
by the body protector.
armhole circumference. The circumference of the armhole
shall be less than 70% of Dimension A (F in Fig. 1).
6.2 All measurements shall be taken from the edge of the
padding material to the edge of the padding material as 6.3.6 The minimum width of padding across the back
designated in 6.3. The outer material that holds the padding between the armholes shall be more than 30% of DimensionA
material shall not be considered to be padding material. (G in Fig. 1).
F2681−08 (2014)
TABLE 1 Sampling and Test Schedule
6.3.7 The minimum width of padding across the chest
between the armholes shall be more than 20% of DimensionA Dimensioning, Closures Impact
Sizing and (11.1) Attenuation
(H in Fig. 1).
Body Coverage (11.2)
6.3.8 The maximum vertical dimension (depth) of the front
(Section 6)
neck opening shall be less than 15% of Dimension B (I in Fig.
Sample 1, Ambient X X X
Sample 2, High Temperature X
1).
Sample 3, Low Temperature X
6.3.9 The maximum vertical dimension (depth) of the back
Sample 4, Water Immersion X
neck opening shall be less than 10% of Dimension B (J in Fig.
1).
6.3.10 The test area shall consist of the area bounded by
8. Sampling and Test Schedule
dimensions A, C, C’, D and D’ as shown in Fig. 1.
8.1 A total of four specimens of each size of the protector
model shall be submitted for testing. The ambient sample shall
7. Apparatus
be tested for dimensioning, sizing, and body coverage prior to
7.1 Dimensioning, Sizing and Coverage—The apparatus for closure testing. Upon completion of closure testing, the ambi-
thedimensioning,sizingandcoverageevaluationshallinclude:
ent sample shall be subjected to impact attenuation testing. A
summary of the sampling and test schedule appears in Table 1.
7.1.1 Cloth Tape Measure, metric, capable of reporting
measurements to the nearest 0.1 cm.
9. Conditioning
7.1.2 Armhole Circumference Measurement Device, shown
9.1 Prior to testing, condition one body protector apiece in
in Fig. 2. The armhole circumference measurement device
each of the following four ways:
shall be fabricated from any material that will not significantly
9.1.1 Ambient Temperature—Condition one body protector
degrade over time. Suitable materials include plastic, metal or
for a period of not less than4hat laboratory conditions at a
wood.
temperature of 21 6 3°C and a relative humidity of 50 6 15%.
7.2 Shock Attenuation Test—The apparatus for the shock
Record the temperature to the nearest degree and the relative
attenuation test shall consist of the following:
humidity to the nearest percent at the time of testing on the
7.2.1 Guide Assembly—The spherical impactor shall be
report form for each test series.
attachedtothefreefalldropassemblycarriagebyanadjustable
9.1.2 Low Temperature—Condition the second body protec-
mounting that will allow impacts to be delivered to any point
tor by exposing it to a temperature of -15 6 3°C for not less
of the body protector within the area designated by 6.3,
than 4 h nor more than 24 h in a mechanically cooled
provided that the center of any impact is not less than 50 mm
apparatus.
from any padding edge, and at least 100 mm from any prior
9.1.3 HighTemperature—Conditionthethirdbodyprotector
impact center. The carriage shall be free to slide on vertical
by exposing it to a temperature of 50 6 3°C for not less than
guides. If wires are used, they shall be placed under at least
4 h nor more than 24 h.
845 N tension. The guide assembly shall not weigh more than
9.1.4 Water Immersion—Condition the fourth body protec-
1.100 kg. The total weight of the guide assembly and spherical
tor by fully immersing in potable water at a temperature of 19
impactor shall be 5.0 6 0.1 kg.
6 3°C for not less than 4 h nor more than 24 h.
7.2.2 Recording Equipment—Therecordingequipmentshall
9.1.5 Testing for Conditioned Specimens—Complete all
meet the following criteria:
testing on body protectors within 5 min after removal from the
7.2.2.1 Acceleration Transducer—A linear accelerometer
conditioning environment. If testing cannot be completed
shall be mounted at the center of gravity of the spherical
within 5 min, the body protector shall be returned to the
impactor and carriage assembly with the sensitive axis aligned
conditioning environment for a minimum of 15 min for each
towithin5°oftheverticalwhenthesphericalimpactorisinthe
5 min period that they are out of the conditioning environment,
impact position. The transducer shall be capable of withstand-
prior to the resumption of testing.
ing a shock of 1000 g without damage and shall have a
10. System Check
frequency respo
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2681 − 08 F2681 − 08 (Reapproved 2014) An American National Standard
Standard Specification for
Body Protectors Used in Equine Racing
This standard is issued under the fixed designation F2681; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
Equine racing is a sport with intrinsic hazards. It is recognized that serious injury or death can result
from both low-energy and high-energy impacts, even when body protectors are worn. It is also
recognized that body protection must be acceptable for the sport, the user, and to the regulating
associations or agencies requiring their use. This specification has been developed with an emphasis
on providing comfortable, nonrestrictive impact protection in a lower weight garment. Injuries will not
be prevented by protective padding in accidents involving severe torsion, flexion or crushing of the
body. Acknowledging these limitations, this specification was developed using resources in the
medical, scientific, engineering, human factors, and biomedical fields, as well as resources from
equine competitors and professional Standardbred drivers and Thoroughbred jockeys. This specifi-
cation draws from work done by others where appropriate for this specification, and these standards
may be referenced. It should be noted that this specification specifies a laboratory test of a completed
body protector’s ability to reduce impacts.
1. Scope
1.1 This specification covers minimum performance criteria and describes test methods for body protectors for use in equine
racing in a controlled environment.
NOTE 1—It is recognized that it is not possible to write a body protector performance standard that will result in products that can protect against all
types of injury or death in an accident.
1.2 It is not the intention of this specification to bar from consideration materials of improved quality or performance not known
at time of development of this specification.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
F1446 Test Methods for Equipment and Procedures Used in Evaluating the Performance Characteristics of Protective Headgear
2.2 BSI Standards:
EN 13158:2000 Protective clothing – protective jackets, body and shoulder protectors for horse riders – Requirements and test
methods
2.3 SAE Standards
SAE J211 Recommended Practice for Instrumentation for Impact Tests – Requirements for Channel Class 1000
This specification is under the jurisdiction of ASTM Committee F08 on Sports Equipment, Playing Surfaces, and Facilities and is the direct responsibility of
Subcommittee F08.55 on Body Padding.
Current edition approved Aug. 1, 2008June 1, 2014. Published September 2008September 2014. Originally approved in 2008. Last previous edition approved in 2008 as
F2681 – 08. DOI: 10.1520/F2681-08.10.1520/F2681-08R14.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Available from British Standards Institute (BSI), 389 Chiswick High Rd., London W4 4AL, U.K., http://www.bsi-global.com.
Available from Society of Automotive Engineers (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001, http://www.sae.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F2681 − 08 (2014)
3. Terminology
3.1 Definitions of Terms Specific to This Standard:
3.1.1 In addition to terms defined in Test Methods F1446, the following terms are specific to this specification.
3.1.2 body protector, n—sleeveless garment covering defined areas of the torso and lower back and consisting of one or more
layers of material and designed to reduce trauma from impacts and falls.
3.1.3 calibration impact surface, n—flat modular elastomer programmer (MEP), as specified in Test Methods F1446.
3.1.4 equine racing, n—any event or activity on a flat dirt, grass, or synthetic surface track that emphasizes the horse’s and
rider’s or driver’s ability to complete a designated distance or course in as short a time as possible (for example, Standardbred,
Thoroughbred, and Quarter Horse racing).
3.1.5 impact surface, n—flat anvil, as specified in the Apparatus section of Test Methods F1446, used as the impact surface for
the shock attenuation test (see 7.2).
3.1.6 padding, n—any material or structure designed to absorb or distribute, or both, impact energy.
3.1.7 spherical impactor, n—spherical impactor, as specified in Test Methods F1446, used for the impact attenuation system
check (see 10.1) and impact test procedures (see 11.2).
4. Materials and Manufacture
4.1 Materials:
4.1.1 All materials used in the fabrication of the body protector shall be known as suitable for the intended application. All
padding materials used in the body protector shall not permanently distort during an exposure of at least 4 h to any temperature
in the range from -15 6 2 to 40 6 2°C, nor shall the material be significantly affected by exposure to ultraviolet radiation, water,
dirt, or vibration.
4.1.2 Materials coming into contact with the wearer’s skin shall not be a type known to cause skin irritation or diseases. These
materials shall not undergo significant loss of strength, flexibility, or other physical change as a result of contact with perspiration
or body oil. Any material used in the construction of body protectors shall not be adversely affected by ordinary household soap
and water, mild household detergent, or cleaners recommended by the manufacturer.
4.1.3 Adhesive materials used to attach padding or straps to the body protector shall be of a formulation that will not alter the
chemical or physical properties of the materials to an extent as to reduce their protective qualities.
4.1.4 The manufacturer of the body protector shall provide written documentation to the testing laboratory indicating that the
materials used in the body protector fulfill the requirements of 4.1.1 – 4.1.3.
4.2 Body Protector Assembly:
4.2.1 Any optional devices provided by the manufacturer of the body protector and fitted to the body protector shall be so
designed that they are unlikely to cause any injury to the wearer or other participants during contact. If the manufacturer provides
optional devices then the body protector shall be tested with the optional devices fitted to the body protector.
4.2.2 Any unfaired projection extending more than 7 mm from the body protector outer surface shall break away or collapse
when impacted with forces equivalent to those produced by the impact tests described in 11.2 of this specification. There shall be
no fixture on the inner surface of the body protector projecting more than 2 mm from the inner surface of the body protector toward
the wearer’s body.
4.3 Extent and Form of Padding—The coverage of the body protector listed in Section 6 shall be capable of being evaluated
according to 11.2 and shall meet the impact requirements of Section 5. The extent of coverage shall include at least all of the
designated areas shown in Fig. 1.
NOTE 2—The body protector may have reduced padding thickness over the shoulder, and it does not require padding in areas outside the test area
defined in Fig. 1.
4.4 Attachments—The components of the fasteners for securing attachments to the body protector shall not reduce the impact
attenuation properties of the body protector.
5. Performance Requirements
5.1 General—Body protectors shall be capable of meeting the requirements in this specification throughout their full range of
adjustment.
5.2 When tested in accordance with 11.1, the force to separate any closures shall not be less than 50 N. This requirement shall
be met at ambient temperature 21 6 3°C and at a relative humidity of 50 6 15 %.
5.3 The velocity of any test impact shall be 3.15 m/s 6 2%. The peak acceleration of any test impact shall not exceed 300 g,
when conditioned as described in 9.1 and when tested in accordance with 11.2.
6. Dimensioning, Sizing and Body Coverage
6.1 The whole circumference of the torso shall be covered by the body protector.
F2681 − 08 (2014)
FIG. 1 Dimensional Coverage Requirements
6.2 All measurements shall be taken from the edge of the padding material to the edge of the padding material as designated
in 6.3. The outer material that holds the padding material shall not be considered to be padding material.
6.3 Dimensioning—Body protectors shall have dimensions as shown in Fig. 1. Dimension A shall be the mid-value of the range
of the chest circumference, in centimetres, that the manufacturer states the body protector will fit. Dimension B shall be reported
in centimetres and defined by the following equation:
B5 20.011 A 12.66A2 65.56 (1)
~ !
which represents the mathematically calculated anthropometric mean for the waist to waist over the shoulder length for chest
sizes of 53 to 122 cm.
6.3.1 Four vertical reference lines, as defined in EN 13158:2000, are to be used: C and C’ separated by 25% of Dimension A
on the chest, and D and D’ separated by 25% of Dimension A on the back.
6.3.2 The padding shall extend for more than 30% of Dimension B along the lines C and C’ (C in Fig. 1).
6.3.3 The padding shall extend for more than 45% of Dimension B along the lines D and D’ (D in Fig. 1).
6.3.4 The padding shall extend for a length greater than 25% of Dimension B in the center front (E in Fig. 1).
6.3.5 The armhole circumference shall be measured by placing the armhole opening over the test device shown in Fig. 2. The
point at which the armhole opening circumference contacts the cone measurement device at all points around the circumference
of the armhole shall be considered to be the armhole circumference. The circumference of the armhole shall be less than 70% of
Dimension A (F in Fig. 1).
6.3.6 The minimum width of padding across the back between the armholes shall be more than 30% of Dimension A (G in Fig.
1).
6.3.7 The minimum width of padding across the chest between the armholes shall be more than 20% of Dimension A (H in Fig.
1).
6.3.8 The maximum vertical dimension (depth) of the front neck opening shall be less than 15% of Dimension B (I in Fig. 1).
6.3.9 The maximum vertical dimension (depth) of the back neck opening shall be less than 10% of Dimension B (J in Fig. 1).
6.3.10 The test area shall consist of the area bounded by dimensions A, C, C’, D and D’ as shown in Fig. 1.
7. Apparatus
7.1 Dimensioning, Sizing and Coverage—The apparatus for the dimensioning, sizing and coverage evaluation shall include:
7.1.1 Cloth Tape Measure, metric, capable of reporting measurements to the nearest 0.1 cm.
7.1.2 Armhole Circumference Measurement Device, shown in Fig. 2. The armhole circumference measurement device shall be
fabricated from any material that will not significantly degrade over time. Suitable materials include plastic, metal or wood.
7.2 Shock Attenuation Test—The apparatus for the shock attenuation test shall consist of the following:
F2681 − 08 (2014)
FIG. 2 Armhole Circumference Measurement Device
7.2.1 Guide Assembly—The spherical impactor shall be attached to the free fall drop assembly carriage by an adjustable
mounting that will allow impacts to be delivered to any point of the body protector within the area designated by 6.3, provided
that the center of any impact is not less than 50 mm from any padding edge, and at least 100 mm from any prior impact center.
The carriage shall be free to slide on vertical guides. If wires are used, they shall be placed under at least 845 N tension. The guide
assembly shall not weigh more than 1.100 kg. The total weight of the guide assembly and spherical impactor shall be 5.0 6 0.1 kg.
7.2.2 Recording Equipment—The recording equipment shall meet the following criteria:
7.2.2.1 Acceleration Transducer—A linear accelerometer shall be mounted at the center of gravity of the spherical impactor and
carriage assembly with the sensitive axis aligned to within 5° of the vertical when the spherical impactor is in the impact position.
The transducer shall be capable of withstanding a shock of 1000 g without damage and shall have a frequency response (variation
6 1.5%) from 5 to 900 Hz.
7.2.2.2 Impact Recording—The impact shall be recorded using digital data processing equipment that complies with the
requirements of SAE J211. The minimum sampling rate shall not be less than 10 kHz, and the resolution shall be not less than
12 bits (including sign).
7.2.2.3 Signal Filtering—Analog or digital filtering of the acceleration data channel shall comply with the requirements of SAE
J211.
7.2.3 Closure Test Equipment—The closure test equipment shall consist of a force gauge capable of measuring up to 100 N
without damage to the device. The force gauge shall have an accuracy of 65% and be capable of reporting force to the nearest
1 N.
8. Sampling and Test Schedule
8.1 A total of four specimens of each size of the protector model shall be submitted for testing. The ambient sample shall be
tested for dimensioning, sizing, and body coverage prior to closure testing. Upon completion of closure testing, the ambient sample
shall be subjected to impact attenuation testing. A summary of the sampling and test schedule appears in Table 1.
9. Conditioning
9.1 Prior to testing, condition one body protector apiece in each of the following four ways:
9.1.1 Ambient Temperature—Condition one body protector for a period of not less than 4 h at laboratory conditions at a
temperature of 21 6 3°C and a relative humidity of 50 6 15%. Record the temperature to the nearest degree and the relative
humidity to the nearest percent at the time of testing on the report form for each test series.
9.
...










Questions, Comments and Discussion