Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings

SIGNIFICANCE AND USE
5.1 The main part of this standard uses procedures originally developed for laboratory measurements of the sound transmission loss of partitions. These procedures assume that the rooms in which the measurements are made have a sound field that reasonably approximates a diffuse field. Sound pressure levels in such rooms are reasonably uniform throughout the room and average levels vary inversely with the logarithm of the room sound absorption. Not all rooms will satisfy these conditions. Practical experience and controlled studies (1)6 have shown that the test method is applicable to smaller spaces normally used for work or living, such as rooms in multi-family dwellings, hotel guest rooms, meeting rooms, and offices with volumes less than 150 cubic meters. The measures appropriate for such spaces are NR, NNR, and ATL. The corresponding single number ratings are NIC, NNIC and ASTC. The ATL and ASTC may be measured between larger spaces that meet a limitation on absorption in the spaces to provide uniform sound distribution.  
5.2 Annex A1 was developed for use in spaces that are very large (volume of 150 m3 or greater). Sound pressure levels during testing can vary markedly across large rooms so that the degree of isolation can vary strongly with distance from the common (separating) partition. This procedure evaluates the isolation observed near the partition. The appropriate measure is NR, and the appropriate single number rating is NIC.  
5.3 Several metrics are available for specific uses. Some evaluate the overall sound isolation between spaces including the effect of absorption in the receiving space and some evaluate the performance or apparent performance of the partition being evaluated. The results obtained are applicable only to the specific location tested.  
5.3.1 Noise Reduction (NR) and Noise Isolation Class (NIC)—Describe the sound isolation found between the two spaces under consideration. Noise reduction data are based on the space- and time aver...
SCOPE
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, usually referred to as flanking paths. Fig. 1 illustrates the direct paths (D) and some possible structural flanking paths (F). Additional non-structural flanking paths may include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms. Sound isolation is also influenced by the size of the separating partition between spaces and absorption in the receiving space, and in the case of small spaces by modal behavior of the space and close proximity to surfaces.
FIG. 1 Direct (D) and Some Indirect or Flanking Paths (F and Dotted) in a Building  
1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition or the apparent sound insulation of the separating partition, including both direct and flanking transmission paths in all cases. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC) which indicate the isolation with the receiving room furnished as it is during the test, the normalized noise reduction (NNR) and normalized noise isolation class (NNIC) which indicate the expected isolation when the receiving room is a normally furnished living or office space that is at least 25 m3 (especially useful when the test must be done with the receiving room unfurnished), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC) which indicate the apparent sound insulating properties of a separating partition including both the direct transmission and flanking transmission through the support structure. The measur...

General Information

Status
Historical
Publication Date
14-Nov-2017
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E336-17a - Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E336-17a - Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E336 − 17a
Standard Test Method for
Measurement of Airborne Sound Attenuation between
1
Rooms in Buildings
This standard is issued under the fixed designation E336; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
INTRODUCTION
This test method is part of a set of standards for evaluating the sound-insulating properties of
building elements. It is designed to measure the sound isolation between two rooms or to estimate
lower limits for sound transmission through a partition element installed as an interior part of a
building. Others in the set cover the airborne sound transmission loss of an isolated partition element
in a controlled laboratory environment (Test Method E90), the laboratory measurement of impact
sound transmission through floors (Test Method E492), the measurement of impact sound transmis-
sion in buildings (Test Method E1007), the measurement of sound transmission through building
facades and facade elements (Guide E966), the measurement of sound transmission through a
common plenum between two rooms (Test Method E1414/E1414M), and measurement of the
normalized insertion loss of doors (Test Method E2964).
1. Scope which indicate the isolation with the receiving room furnished
as it is during the test, the normalized noise reduction (NNR)
1.1 The sound isolation between two spaces in a building is
andnormalizednoiseisolationclass(NNIC)whichindicatethe
influenced most strongly by a combination of the direct
expected isolation when the receiving room is a normally
transmission through the nominally separating building ele-
3
furnishedlivingorofficespacethatisatleast25m (especially
ment(asnormallymeasuredinalaboratory)andanytransmis-
useful when the test must be done with the receiving room
sion along a number of indirect paths, usually referred to as
unfurnished), and the apparent transmission loss (ATL) and
flanking paths. Fig. 1 illustrates the direct paths (D) and some
apparent sound transmission class (ASTC) which indicate the
possiblestructuralflankingpaths(F).Additionalnon-structural
apparent sound insulating properties of a separating partition
flanking paths may include transmission through common air
including both the direct transmission and flanking transmis-
ducts between rooms, or doors to the corridor from adjacent
sion through the support structure.The measurement ofATLis
rooms. Sound isolation is also influenced by the size of the
3
limited to spaces of at least 25 m where modal effects create
separating partition between spaces and absorption in the
fewer problems. With the exception of the ATL and ASTC
receiving space, and in the case of small spaces by modal
underspecifiedconditions,theseproceduresinthemainpartof
behavior of the space and close proximity to surfaces.
the test method are only applicable when both room volumes
1.2 Themainpartofthistestmethoddefinesproceduresand
3
are less than 150 m .
metrics to assess the sound isolation between two rooms or
NOTE 1—The word “partition” in this test method includes all types of
portions thereof in a building separated by a common partition
walls, floors, or any other boundaries separating two spaces. The bound-
or the apparent sound insulation of the separating partition,
aries may be permanent, operable, or movable.
including both direct and flanking transmission paths in all
1.3 The NR and NIC between two locations may always be
cases. Appropriate measures and their single number ratings
measuredandreportedthoughconditionspresentwillinfluence
are the noise reduction (NR) and noise isolation class (NIC)
how measurements are made. Restrictions such as minimum
room volume or dimensions or maximum room absorption are
1 imposed for all other measures and ratings in this standard.
ThistestmethodisunderthejurisdictionofASTMCommitteeE33onBuilding
and Environmental Acoustics and is the direct responsibility of Subcommittee
Thus,conditionsmayexistthatwillnotallowNNR(NNIC)or
E33.03 on Sound Transmission.
ATL(ASTC) to be reported. Where a partition between rooms
Current edition approved Nov. 15, 2017. Published November 2017. Originally
is composed of parts that are constructed differently, or
approved in 1971. Last previous edition approved in 2017 as E336–17. DOI:
10.1520/E0336-17A. containsanelementsuchasadoor,itisnotpossibletomeasure
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E336 − 17a
FIG. 1 Direct (D) and Som
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E336 − 17 E336 − 17a
Standard Test Method for
Measurement of Airborne Sound Attenuation between
1
Rooms in Buildings
This standard is issued under the fixed designation E336; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
INTRODUCTION
This test method is part of a set of standards for evaluating the sound-insulating properties of
building elements. It is designed to measure the sound isolation between two rooms or to estimate
lower limits for sound transmission through a partition element installed as an interior part of a
building. Others in the set cover the airborne sound transmission loss of an isolated partition element
in a controlled laboratory environment (Test Method E90), the laboratory measurement of impact
sound transmission through floors (Test Method E492), the measurement of impact sound transmis-
sion in buildings (Test Method E1007), the measurement of sound transmission through building
facades and facade elements (Guide E966), the measurement of sound transmission through a
common plenum between two rooms (Test Method E1414/E1414M), and measurement of the
normalized insertion loss of doors (Test Method E2964).
1. Scope
1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission
through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number
of indirect paths, usually referred to as flanking paths. Fig. 1 illustrates the direct paths (D) and some possible structural flanking
paths. paths (F). Additional non-structural flanking paths may include transmission through common air ducts between rooms, or
doors to the corridor from adjacent rooms. Sound isolation is also influenced by the size of the separating partition between spaces
and absorption in the receiving space, and in the case of small spaces by modal behavior of the space and close proximity to
surfaces.
1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions
thereof in a building separated by a common partition or the apparent sound insulation of the separating partition, including both
direct and flanking transmission paths in all cases. Appropriate measures and their single number ratings are the noise reduction
(NR) and noise isolation class (NIC) which indicate the isolation with the receiving room furnished as it is during the test, the
normalized noise reduction (NNR) and normalized noise isolation class (NNIC) which indicate the expected isolation when the
3
receiving room is a normally furnished living or office space that is at least 25 m (especially useful when the test must be done
with the receiving room unfurnished), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC)
which indicate the apparent sound insulating properties of a separating partition. partition including both the direct transmission
3
and flanking transmission through the support structure. The measurement of ATL is limited to spaces of at least 25 m where
modal effects create fewer problems. With the exception of the ATL and ASTC under specified conditions, these procedures in the
3
main part of the test method are only applicable when both room volumes are less than 150 m .
NOTE 1—The word “partition” in this test method includes all types of walls, floors, or any other boundaries separating two spaces. The boundaries
may be permanent, operable, or movable.
1.3 The NR and NIC between two locations may always be measured and reported though conditions present will influence how
measurements are made. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed
for all other measures and ratings in this standard. Thus, conditions may exist that will not allow NNR (NNIC), (NNIC) or ATL
1
This test method is under the jurisdiction of ASTM Committee E33 on Building and Environmental Acoustics and is the direct responsibility of Subcommittee E33.03
on Sound Transmission.
Current edition approved July 1, 2017Nov. 15, 2017. Published November 2017. Originally approved in 1971. Last previous edition approved in 20162017 as
E3
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.