SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) sewer pipe and fittings.
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: D 3034 – 04a
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and
1
Fittings
This standard is issued under the fixed designation D 3034; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope D 2152 Test Method for Adequacy of Fusion of Extruded
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
1.1 This specification covers requirements and test methods
Acetone Immersion
for materials, dimensions, workmanship, flattening resistance,
D 2321 Practice for Underground Installation of Thermo-
impact resistance, pipe stiffness, extrusion quality, joining
plastic Pipe for Sewers and Other Gravity-Flow Applica-
systems and a form of marking for type PSM poly(vinyl
tions
chloride) (PVC) sewer pipe and fittings.
D 2412 Test Method for Determination of External Loading
1.2 Pipeandfittingsproducedtothisspecificationshouldbe
Characteristics of Plastic Pipe by Parallel-Plate Loading
installed in accordance with Practice D 2321.
D 2444 Test Method for Impact Resistance of Thermoplas-
1.3 The text of this specification references notes, footnotes,
tic Pipe and Fittings by Means of a Tup (Falling Weight)
and appendixes which provide explanatory material. These
D 2564 Specification for Solvent Cements for Poly(Vinyl
notesandfootnotes(excludingthoseintablesandfigures)shall
Chloride) (PVC) Plastic Piping Systems
not be considered as requirements of the specification.
D 2749 Symbols for Dimensions of Plastic Pipe Fittings
1.4 The values stated in inch-pound units are to be regarded
D 2855 Practice for Making Solvent-Cemented Joints with
as the standard. The values given in parentheses are for
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
information only.
D 3212 Specification for Joints for Drain and Sewer Plastic
1.5 The following precautionary caveat pertains only to the
Pipes Using Flexible Elastomeric Seals
test methods portion, Section 8, of this specification: This
F 412 Terminology Relating to Plastic Piping Systems
standard does not purport to address all of the safety concerns,
F 1336 Specification for Poly(Vinyl Chloride) (PVC) Gas-
if any, associated with its use. It is the responsibility of the user
keted Sewer Fittings
of this standard to establish appropriate safety and health
3
2.2 Federal Standard:
practices and determine the applicability of regulatory limita-
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
tions prior to use.
3
2.3 Military Standard:
2. Referenced Documents
MIL-STD-129 Marking for Shipment and Storage
2
2.1 ASTM Standards:
3. Terminology
D 618 Practice for Conditioning Plastics for Testing
3.1 Definitions—Definitions are in accordance with Termi-
D 1600 Terminology for Abbreviated Terms Relating to
nology F 412, and abbreviations are in accordance with Ter-
Plastics
minologyD 1600,unlessotherwisespecified.Theabbreviation
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
of poly(vinyl chloride) plastics is PVC.
Compounds and Chlorinated Poly(Vinyl Chloride)
3.1.1 The term PSM is not an abbreviation but rather an
(CPVC) Compounds
arbitrary designation for a product having certain dimensions.
D 2122 Test Method for Determining Dimensions of Ther-
moplastic Pipe and Fittings
4. Significance and Use
4.1 The requirements of this specification are intended to
provide pipe and fittings suitable for non-pressure drainage of
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
sewage and surface water.
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Nov 1, 2004. Published November 2004. Originally NOTE 1—Industrial waste disposal lines should be installed only with
approved in 1972. Last previous edition approved in 2004 as D 3034 – 04.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
the ASTM website. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D 3034 – 04a
the specific approval of the cognizant code authority since chemicals not
accordance with 8.4.1.
commonly found in drains and sewers and temperatures in excess of 60°C
NOTE 2—As larg
...
Questions, Comments and Discussion